02-14-2013, 10:25 PM
Thread: Heat Pump Gauge Use.
by rwk26164- Replies
- 58
- Views
- 3,321
Except for units that use a txv in the od unit....
Except for units that use a txv in the od unit. After the first few years of servicing only bryant equip. the company I was working for started also dealing lennox. I noticed the abscence of...
-
07-23-2010, 04:48 PM
Thread: Suction side pulling vaccum
by rwk26164- Replies
- 9
- Views
- 1,114
liquid line strainer just before metering device...
liquid line strainer just before metering device could be blocked, should be freezing or have a temp diff. at restriction
-
07-23-2010, 04:46 PM
Thread: A/C Not working properly
by rwk26164- Replies
- 27
- Views
- 1,425
sounds like a lot of guessing until someone comes...
sounds like a lot of guessing until someone comes out. can't believe they wont be back until next week
-
07-20-2010, 10:24 PM
- Replies
- 13
- Views
- 2,047
yep, better just bite the bullet and let the tech...
yep, better just bite the bullet and let the tech try one thing at a time.
-
07-20-2010, 10:20 PM
- Replies
- 92
- Views
- 4,374
Keep looking for a contractor. would never use...
Keep looking for a contractor. would never use flex unless sleved with rigid pipe. What are they going to with heat tape on the condensate line and then let the trap freeze? I know that they make a...
-
07-20-2010, 10:12 PM
Thread: How many tons is my kanmore HVAC system?
by rwk26164- Replies
- 4
- Views
- 361
I vote 3tons or is it 36,000 btu?
I vote 3tons or is it 36,000 btu?
-
07-20-2010, 10:09 PM
- Replies
- 10
- Views
- 560
Would be better to get these systems in during...
Would be better to get these systems in during construction in my opinion for the simple fact that it can be scheduled and completed during the normal constuction cycle. You know before flooring is...
-
07-20-2010, 09:59 PM
- Replies
- 19
- Views
- 1,630
Would change evap and mtering device. R410A...
Would change evap and mtering device. R410A metering devices are about 15% smaller than on r22. Also How much Oil will be left in the r22evap? The question is how much wax will be in that oil to clog...
-
07-20-2010, 09:45 PM
- Replies
- 12
- Views
- 1,337
Agree with beenthere. also would have electrician...
Agree with beenthere. also would have electrician check furnace, o.d. unit wiring.
-
07-20-2010, 09:38 PM
Thread: Head pressure fluctuating
by rwk26164- Replies
- 8
- Views
- 691
sounds like liquid may be migrating through...
sounds like liquid may be migrating through system, is condenser coil clean, ran into this once and the s/a's were all closed
-
07-20-2010, 09:34 PM
Thread: Copeland Scroll Compressor replacement
by rwk26164- Replies
- 4
- Views
- 764
should not have to add oil
should not have to add oil
-
07-17-2010, 10:54 AM
Thread: Trouble with A/C swapout
by rwk26164- Replies
- 25
- Views
- 1,383
Agree with Crazy4. As for the txv I would try to...
Agree with Crazy4. As for the txv I would try to manipulate it with hot water soaked rag or glass off ice water.
-
07-17-2010, 10:47 AM
- Replies
- 7
- Views
- 409
Yes can be done, in fact I use that application...
Yes can be done, in fact I use that application in my house. Just remember that the HP operation will supply lower temps than your fossil fuel system. The contractor that you decide to use should be...
-
07-17-2010, 10:41 AM
Thread: Carrier needs service
by rwk26164- Replies
- 13
- Views
- 617
Something to think about. The new ahu will be...
Something to think about. The new ahu will be matched to the od unit, and have a new blower motor instead of a 26 year old one (if not already replaced).
-
07-17-2010, 10:30 AM
- Replies
- 6
- Views
- 893
Generally the reversing valve energizes when the...
Generally the reversing valve energizes when the tstat is placed in "cool" and de-energizes when switched off of cool. This can be the opposite way in some systems but it is interesting that until...
-
07-17-2010, 10:22 AM
- Replies
- 5
- Views
- 1,947
Wait for the Tech
As stated in the prev. posts there is really no actions that you can take except for waiting for the tech to arrive. I can explain a little about what is happening though.
The fast blinking light is... -
07-17-2010, 09:59 AM
Thread: Please help, not sure what to do!
by rwk26164- Replies
- 33
- Views
- 1,682
electronic leak detector
I have found that in addition to pressure checking the system the use of an electronic leak detector saves me and the customer time and money. Yes I had to buy it myself. No I don't cry about it to...
-
07-17-2010, 09:48 AM
Thread: Mismatch? R410 condenser w R22 evap
by rwk26164- Replies
- 7
- Views
- 1,903
410a metering device
The metering device used in a 410a system is about 15% smaller in capacity as opposed to a metering device used in a R22 system of the same capacity. Only a metering device designed for 410a should...