Search:

Type: Posts; User: dean martin

Search: Search took 0.01 seconds.

  1. Replies
    6
    Views
    1,085

    It's the staging algorithm in the thermostat that...

    It's the staging algorithm in the thermostat that controls this, and each major Tstat guy does these types of things slightly different....so when you ask is this "normal" it kind of depends on brand...
  2. Thread: Liq Driers

    by dean martin
    Replies
    6
    Views
    480

    Well it's a filter and a drier. I suspect...

    Well it's a filter and a drier. I suspect moisture capacity would not really be impacted, but the internal "stacking" of filter screens and pads etc is done with specific purpose from inlet to...
  3. I guess an option could be to wire it as a legacy...

    I guess an option could be to wire it as a legacy 24V system using a non-communicating Tstat.

    Are there any fault codes stored on either the ID or OD control boards?
  4. Replies
    6
    Views
    2,357

    If the circulator is on continuosly in the summer...

    If the circulator is on continuosly in the summer it will re-evaporate some of the water sitting in the A coil drain pan during off cycle, adding humidity just removed back into your space....so...
  5. Replies
    49
    Views
    4,013

    So when you do replace an existing drier should...

    So when you do replace an existing drier should it be cut out or is it OK to un-sweat it?
  6. Replies
    29
    Views
    4,288

    JEZ is not communicating, JEC is. The control...

    JEZ is not communicating, JEC is. The control board has fault recall, so besides the current display the last 6 faults can be retrieved, with a max of 3 consecutive identical faults. Contractor...
  7. There are dipswitches on the control board which...

    There are dipswitches on the control board which have to be properly set for operation with either a single stage or two-stage non-communicating thermostat. There is also an option for stage delay...
  8. The Goodman ComfortNet control is another option...

    The Goodman ComfortNet control is another option to look at if the AC unit you plan to add is also communicating. In this case it unlocks some functionality that traditional tstats can't provide...
  9. Based on literature I have it's time/temp...

    Based on literature I have it's time/temp 30/60/90/120 dipswitch selectable, or can be set up to operate as Loonie mentions for "Auto" defrost but that is only possible if used with the Infinity...
  10. Replies
    20
    Views
    2,064

    There are folks making wireless solutions like a...

    There are folks making wireless solutions like a Jackson Systems "wireless relay" wr-400, think they have even been advertising on this site a bunch recently.
  11. Replies
    18
    Views
    5,753

    Pretty sure Lennox uses a 30 second compressor...

    Pretty sure Lennox uses a 30 second compressor shutdown going into, and coming out of defrost, so it would be normal to hear some noises. Does the unit seem to be clear of ice, that is defrosting...
  12. Replies
    46
    Views
    5,946

    When a node (AH or Heat Pump) "drop" off the...

    When a node (AH or Heat Pump) "drop" off the network and then automatically re-establish you will get the "SYS Config Changed" message. Besides a power outage there are other things that can make a...
  13. Replies
    46
    Views
    5,946

    I double checked and the AH lockout feature only...

    I double checked and the AH lockout feature only operates in normal heating mode. When in defrost the AH is never locked out. Your installer ought to be able to verify that the AH control board is...
  14. Replies
    46
    Views
    5,946

    Jtrammel is correct. If the OP's system is wired...

    Jtrammel is correct. If the OP's system is wired as full comm it only needs four wires....R, C, 1 (data), 2 (data). Installing contractor should verify thermostat setup feature for Air Handler...
  15. The 5 second setting in not adjustable via the...

    The 5 second setting in not adjustable via the circuit board.

    The only way to choose between the 0/5/15/30 second values is by utilizing the ComfortNet tstat and wiring as a full communicating...
  16. Replies
    13
    Views
    712

    There are not really any special tools needed to...

    There are not really any special tools needed to trouble shoot these, they do log faults in a buffer that can be displayed on the control board and in a service menu on the thermostat. An option, if...
  17. Replies
    9
    Views
    1,889

    The Amana ComfortNet is also a state-of-the-art...

    The Amana ComfortNet is also a state-of-the-art serial communicating system with automatic setup, system-wide data sharing including thermostat alerts and fault logging, as well as protective...
  18. Replies
    1
    Views
    422

    You might also look at WR 1F95EZ-0671 which does...

    You might also look at WR 1F95EZ-0671 which does multi-stage heat pump, these are "Easy Readers" with even larger display, but traditional buttons. 1F95-1277 will do multi-stage HP if you prefer...
  19. Replies
    6
    Views
    5,425

    Had a coworker with same problem on a Rheem only...

    Had a coworker with same problem on a Rheem only in winter/heating. Rheem District Tech Rep came out and assisted the service company. It was recommended to triple evacuate the system and then...
  20. Replies
    32
    Views
    2,193

    Andy are all Sporlan products (including Standard...

    Andy are all Sporlan products (including Standard Machine that makes solenoid valves for Sporlan) made in USA?

    All major sub components like brass forgings, etc made in good 'ol Washington, MO?
  21. Replies
    12
    Views
    3,070

    Bricks on the wall weren't laid straight, right?

    Bricks on the wall weren't laid straight, right?
  22. Replies
    11
    Views
    2,580

    That doesn't look like an Alco biflow drier,...

    That doesn't look like an Alco biflow drier, regular EK...
  23. Replies
    4,843
    Views
    301,030

    Interesting Cocktail: Sweaty Goat's Ass ...

    Interesting Cocktail:

    Sweaty Goat's Ass

    3/4 shot white Tequila
    6 drops Tabasco sauce
    1/4 shot Cream or milk

    Pour in tequila first and top off with milk or cream. Then, add 6...
Results 1 to 23 of 24