    xenta 511 hardware v.3 issues

    I just purched a new xenta 511 controler to replace a bad one. The new 511 is a V5.1.8 SP1 with hardware version 3. My project is an xBuilder v1.4. When I try to download the installer package...
  2. Replies
    2
    Views
    415

    Xenta 527 router locking up switch

    I have a Xenta 527 installed in a building that keeps locking up the buildings Ethernet switch. I can reset it and the unit will run fine for about a week then it will lock up the entire switch. ...
  3. Replies
    6
    Views
    497

    By the way, Thanks for your help!

    By the way, Thanks for your help!
  4. Replies
    6
    Views
    497

    I tried PLC center and they said they had several...

    I tried PLC center and they said they had several in stock but when they sent me a picture of the unit it didn't match the description at all. Perhaps I have a bad part number. What I need is a...
  5. Replies
    6
    Views
    497

    Looking to buy controllers

    I have a customer who would like to purchase AUTOMATED LOGIC P/N: I/O-8168R controllers on a continual basis. If you have access to them please let me know.
  6. Replies
    0
    Views
    218

    Inet OSS not working

    I have had several buildings recently that are having issues with the OSS schedule not working. In short, the OSS block is not following the time schedule block that it is mirrored to. I have had...
  7. Replies
    0
    Views
    211

    Inet alarms and reporting reload

    I have a building where the host PC just melted down. I have reinstalled Inet seven and everything is back online now. The building is setup as a DLA link archetecture with 3 netplus routers...
  8. Schneider Electric to discontinue Inet lines?

    I just heard that as on December 31 2013 Schneider Electric is planning on discontinuing the Inet control line. Is there any truth to this? If so how do they plan on supporting all of the customers...
  9. Replies
    1
    Views
    707

    Inet tablet compatability

    My service pc is on its last leg. I was wondering if anyone has had any luck installing inet, I have the current version 2.42, on a tablet? I will be primarily using the wireless network to...
  10. Replies
    2
    Views
    647

    TAC 7716 Tekmar compatability

    I am trying to take over the snowment system for a hotel. I am using a TAC/ Schnieder Electric 7716 control board to do the work. Currently they are using a Tekmar snow melt system. Everything...
  11. Replies
    1
    Views
    577

    Inet alarms management

    I am working with a building that has inet software installed. It has 3 NPR's installed. I keep getting an alarm indicating comm loss to one of the routers. This has been an issue for this building...
  12. Replies
    1
    Views
    334

    Service agreement contract

    Do any of you have a service agreement contract you would be willing to share? I recently started a new HVAC building controls company. The legal/paperwork aspects of business are definitely my...
  13. Replies
    0
    Views
    306

    inet trending issue

    I have an Inet system that is collecting trending data from a controller. The issue is it only collects data thru the 14 of each month. Where do I need to go to make the change to collect data for...
  14. Replies
    14
    Views
    1,604

    I tried Wireshark. I got the IP for my computer...

    I tried Wireshark. I got the IP for my computer and 0.0.0.0 as the only responses. When I cycle power on the NPR I see activity but no valid addresses. I wonder if the whole NPR is hosed.
  15. Replies
    14
    Views
    1,604

    Thanks BACnet. I have never used Wireshark. I...

    Thanks BACnet. I have never used Wireshark. I am currently downloading it. Ill give it a shot and respond later.
  16. Replies
    14
    Views
    1,604

    TAC Netplus Router Address

    I have a TAC Series 2000 Netplus Router that I am trying to resurrect. My issue is I dont know the IP address for the unit. I tried to connect directly to the unit using a serial cable but that...
  17. Replies
    4
    Views
    661

    Thank you! Sometimes the noggin doesnt work...

    Thank you! Sometimes the noggin doesnt work exactly right. I am up and running now.
  18. Replies
    4
    Views
    661

    TAC 7716 4-20mA Conversion Coefficient

    Hello all,
    Does any one know the conversion coefficien needed to have a 4-20 mA connected to a Schneider/TAC/CSI 7716 controller. It is a current sensing trasmitter with a range of 0-100 amps. I...
Results 1 to 18 of 18