  1. Replies
    23
    Views
    2,350

    Recently, install crew added a txv to a lennok...

    Recently, install crew added a txv to a lennok coil that would supposedly bring the SEER rating up from 14 to 16. After install, i get called out for servvice and the unit is pulling LRA. (Lennox by...
  2. Replies
    21
    Views
    2,452

    I would go with the hall common return. I am not...

    I would go with the hall common return. I am not looking into the closet but i cant imagine a scenario where trying to install a plennum for an already installed closet unit could be economical or...
  3. Replies
    18
    Views
    2,003

    on older machines i will sometimes use a larger...

    on older machines i will sometimes use a larger capacitor just to give it a little more kick. But only when the correct size is having a hard time starting the motor or capacitor. Then theres the...
  4. Because we are even considering the possibilty...

    Because we are even considering the possibilty that the units might NOT need replacing, i can assume that the fire damage was not extensively damaging to anything regarding the a/c. If an electrical...
  5. Replies
    22
    Views
    3,529

    Make sure all employees are fully aware of the...

    Make sure all employees are fully aware of the refrigerants they are recovering and transfering into the big buy back bottle. The check thaty normally would have been about $1200 reduced to $350...
  6. Replies
    29
    Views
    3,108

    I agree with the sonic headphones idea. My dad...

    I agree with the sonic headphones idea. My dad had some antique looking ones given to him and they have really been usefull for quickly finding the more difficult leaks. That would be my next step...
  7. Replies
    19
    Views
    2,645

    I just started driving a van for a company that...

    I just started driving a van for a company that just recently hired me. I have also driven another van for a previous employer. But through my expiriences, i am stil a pick up truck man. Despite what...
  8. Replies
    13
    Views
    2,331

    i love mini splits. I do not love working on mini...

    i love mini splits. I do not love working on mini splits however. I have charged a unit based off of performance (DT), without having to dump and recharge. That was on a unit i knew had a small leak....
  9. Replies
    15
    Views
    1,627

    Compressor leads blow out!!

    Just an interesting story i thought i would share about an air conditioner i encountered yesterday. Customer says the unit trips breaker and she leads me to disconnect ( breaker style), which is...
  10. Replies
    18
    Views
    1,494

    perhaps the thermostat is HP capable but needs to...

    perhaps the thermostat is HP capable but needs to be re-programmed......
  11. Replies
    17
    Views
    3,305

    Consider the level of intelligence that fills and...

    Consider the level of intelligence that fills and refills a dairy product into the machine. The chances that the "intelligent person" will spill and get the ice cream mix all over everything on and...
  12. Replies
    21
    Views
    6,238

    Sweet! Very detaile! OCD level straightness on...

    Sweet! Very detaile! OCD level straightness on all the plumbing and dust! I am impressed.
  13. Replies
    41
    Views
    11,719

    In my limited expirience in the commercial...

    In my limited expirience in the commercial kitchen world i have learned that what you must be is a problem solver in order to succeed. That means nothing is too hard, too complicated, or too...
  14. Replies
    73
    Views
    6,731

    I have seen this black flaking of the copper on...

    I have seen this black flaking of the copper on two commercial package units. Diagnosed that it was due to a reccuring problem with sewer gas in the building. The evap coil kept springing new leaks....
  15. Replies
    17
    Views
    3,305

    try cleaning one that has been exposed to sewer...

    try cleaning one that has been exposed to sewer gas for a lengthy amount of time. Talk about nasty! Second floor of a cheap hotel at that. So you get the moldy smelling carpet and the ice with green...
  16. Replies
    18
    Views
    1,494

    Relay

    You mentioned that it was a heat pump, so i can assume your motor is 240v. Being a heat pump, i can also conclude that there will be a call for high speed fan in both heaing and cooling mode. Simply...
  17. Replies
    44
    Views
    3,142

    honesty is good

    my dad had a delema one time. We drove an hour and a half to a job and realized we didnt have enough oxygen for our torches to do the jjob. This job was in Iraan so it was in the middle of no where....