  1. Replies
    35
    Views
    1,998

    I would appreciate a copy. Email in...

    I would appreciate a copy. Email in profile.....thanks.
  2. Replies
    3
    Views
    238

    If you have a Bacnet license already and want to...

    If you have a Bacnet license already and want to trend in the Jace.......then you are good to go. You don't need the Tcomm driver. The Tcomm driver is required to pull trending out of the EasyIO. ...
  3. Thread: Trane UPCM to PCG

    by ascj
    Replies
    4
    Views
    187

    I normally find it easier to just go through the...

    I normally find it easier to just go through the Inputs and open them. It's quicker then going through UPCMedit.
  4. Replies
    3
    Views
    238

    Do you need schedules and histories? EasyIO's...

    Do you need schedules and histories? EasyIO's can be brought into a Jace via Bacnet MS/TP or TCP, Modbus, or Sedona. Tcom driver gives you the most flexibility. But if price is a issue and you...
  5. Replies
    2
    Views
    178

    Will agree with chadtech.........this was an...

    Will agree with chadtech.........this was an issue with their 3.7.46.4 driver and earlier.

    It has been resolved......if you need the newest driver, just let me know. Also, if your module is...
  6. Replies
    9
    Views
    495

    What was the model of RTU? What was the actual...

    What was the model of RTU? What was the actual alarm you were seeing? Is it the VFD that is locking out? Why isn't the phase monitor shutting the unit down, first?

    My experience with Carrier...
  7. Replies
    3
    Views
    205

    I trigger it by UnOccupied to Occupied. Then...

    I trigger it by UnOccupied to Occupied. Then setup a max time and a start/stop temps.

    Here is the application I use-

    499511
  8. Replies
    6
    Views
    440

    Just curious....why the 7 Jace 700's?

    Just curious....why the 7 Jace 700's?
  9. Thread: Jace CCN Inteface

    by ascj
    Replies
    15
    Views
    618

    You might want to look into bringing them in...

    You might want to look into bringing them in Bacnet with a UPC Open Controller for each. Another option is a Ivu link. You are limited to 500 Bacnet points, but with just 4 chillers.....that should...
  10. Thread: Carrier Ivu

    by ascj
    Replies
    1
    Views
    184

    Carrier Ivu

    Is there a network point limit per controller?

    I have a 6400 on a Ivu 4.2, that I'm trying to fix some points. Looking at the equipment file they are all there and mapped. I download to the Ivu...
  11. Replies
    7
    Views
    923

    You verified you only have one broadcast...

    You verified you only have one broadcast acknowledger per buss? You verified you only have one controller per schedule broadcasting? Meaning you don't have duplicate schedule numbers being...
  12. Thread: Service tool 5

    by ascj
    Replies
    7
    Views
    501

    Sent you an email.

    Sent you an email.
  13. Replies
    5
    Views
    225

    Sent you an email.

    Sent you an email.
  14. Replies
    5
    Views
    225

    It's amazing how often they update their drivers....

    It's amazing how often they update their drivers. The newest version I have is 3.7.106.2.

    I sent a email to my connection at Maxline for the newest driver and their patch notes. But since the...
  15. Replies
    5
    Views
    225

    What version driver? What kinda of devices?

    What version driver? What kinda of devices?
  16. Replies
    19
    Views
    2,596

    360 seconds is the stroke time. Be careful with...

    360 seconds is the stroke time. Be careful with retrofit controllers......those VAV's have ends switches, which can wreck some controllers with triacs. You can add some isolation relays or add some...
  17. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    295

    My bad....yes they are Gen3. I'm changing the...

    My bad....yes they are Gen3. I'm changing the BCACK point. It just doesn't recognize the buss, element when I do a scan for broadcast acknowledgers.

    Anyway, I spent some more time with the...
  18. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    295

    No....I'm changing the controller to a broadcast...

    No....I'm changing the controller to a broadcast acknowledger......but when I do a buss scan on that buss, my service tool show nothing. I'm pretty familiar with using the Carrier service tool and...
  19. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    295

    Changes and scanning are through NSTV. No Ivu...

    Changes and scanning are through NSTV. No Ivu onsite.
  20. Thread: CCN Issue

    by ascj
    Replies
    10
    Views
    295

    CCN Issue

    I have a building, I'm trying to straighten out. They have two CCN busses. One for the first floor with 48 devices and one for the 2nd flr with 52 devices. I know I need a broadcast acknowledger...
  21. Replies
    3
    Views
    149

    JCI's default IP is 192.168.1.149. You should no...

    JCI's default IP is 192.168.1.149. You should no issues using you webs workbench......just copy the modules. The default credentials with be user- jci and password- explorer
  22. Replies
    6
    Views
    259

    No I was wrong......that is the case with...

    No I was wrong......that is the case with Voyagers/Precedents and VAV's. I was a little off kilter, last night. DaveM is correct. Sounds like your dip switches are set wrong.

    TCI Installation...
  23. Replies
    6
    Views
    259

    He didn't mention vintage........but I was...

    He didn't mention vintage........but I was assuming TCI-4 boards. Since he has the ability to change the address from the HMI's.
  24. Replies
    3
    Views
    264

    TUNCOS just offsets setpoints based on time to...

    TUNCOS just offsets setpoints based on time to next event.....its a Honeywell thing.

    We haven't done much with pneumatic VAV's with XL10's.........but I do remember John Hutchey mentioning this...
  25. Replies
    6
    Views
    259

    Not sure what literature you are looking...

    Not sure what literature you are looking at......but Intellipaks start there network working adressing at 32. So a local configured address of 1 is 32 on the Comm4 network. Voyagers and Precedents...