Search:

Type: Posts; User: AJS HVAC

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    48
    Views
    2,432

    Glad to see some of the guys here are having...

    Glad to see some of the guys here are having positive results with the Triple D. Ive been happy with it and a few guys I work with have switched as well. I just wish a few more supply houses would...
  2. Replies
    29
    Views
    1,350

    Mine are brand new. It has pulled cores on a few...

    Mine are brand new. It has pulled cores on a few pieces of equipment but it's not consistent at all. It takes a great deal of force (for a core removal) to get it to grab.
  3. Replies
    16
    Views
    624

    I've used it on 1 1/8th but I just didn't like...

    I've used it on 1 1/8th but I just didn't like how long it took for a rod to flow on the joint. I do agree if doing residential it's better for lighting in a home than oxygen acetylene. I've got used...
  4. Thread: H-10G

    by AJS HVAC
    Replies
    9
    Views
    507

    I wouldn't mess with stuff like that personally....

    I wouldn't mess with stuff like that personally. I wouldn't do it as far as messing with calibrations
  5. Replies
    16
    Views
    624

    The acetylene takes too long in my opinion. I can...

    The acetylene takes too long in my opinion. I can see how using a smaller setup in a tight space would be beneficial. I've tried it in the past when a guy I work with has this setup. I found once you...
  6. Replies
    7
    Views
    263

    I agree with you. Craftsman is especially dropped...

    I agree with you. Craftsman is especially dropped in quality ever since Kmart bought sears.
  7. Replies
    7
    Views
    263

    Yellow jacket or tools in general?

    Yellow jacket or tools in general?
  8. Replies
    5
    Views
    394

    I have had two of these pumps now. I had one at...

    I have had two of these pumps now. I had one at my old job, and when I got my new job they said go get what ya need and get good quality. I purchased another one of these pumps (6cfm 2stage). The...
  9. Thread: H-10G

    by AJS HVAC
    Replies
    9
    Views
    507

    I'm sorry 1/8th turn don't do half sorry for...

    I'm sorry 1/8th turn don't do half sorry for confusion
  10. Thread: H-10G

    by AJS HVAC
    Replies
    9
    Views
    507

    Supposedly Bacharach says turn the calibration...

    Supposedly Bacharach says turn the calibration screw half turn to increase sensitivity . I don't like the idea of messing with settings like that. I've done that in the past and never worked quite...
  11. Agreed with above

    Agreed with above
  12. Replies
    29
    Views
    1,350

    The C&D rod works with the yellow jackets but for...

    The C&D rod works with the yellow jackets but for the money charged for the yellow jackets you shouldn't have to do that
  13. Replies
    29
    Views
    1,350

    Which removal tool do you own? I have the model...

    Which removal tool do you own? I have the model with the side port for access.
  14. Replies
    7
    Views
    263

    18975 yellow jacket core removal tool

    I bought two of these tools recently and have had issues with the plunger assembly pulling the cores out.
    If I put the C&D stem in, no issues but I use the yellow jacket and it won't pull the...
  15. Replies
    29
    Views
    1,350

    I bought the yellow jackets as well thinking it...

    I bought the yellow jackets as well thinking it would be good as well. Bought two actually and hate them. Havnt been very happy lately with their stuff. Have a set of 6foot ball valve hoses I bought...
  16. Thread: H-10G

    by AJS HVAC
    Replies
    9
    Views
    507

    Yeah there is a lot of feedback on it if you do a...

    Yeah there is a lot of feedback on it if you do a search on here
  17. Replies
    23
    Views
    2,977

    I have never understood forcing the knobs

    I have never understood forcing the knobs
  18. Replies
    23
    Views
    2,977

    I am bringing back the Brute II manifold. Really...

    I am bringing back the Brute II manifold. Really disappointed with it. The high side gauge flutters like crazy, then when trying to charge a unit the manifold will just quit flowing, I have to purge...
  19. Replies
    18
    Views
    1,115

    Yes it is. At least that was the case 8 years ago...

    Yes it is. At least that was the case 8 years ago when I worked at a parts house where we sold equipment. Maybe copeland loosened up some on their policies.
    I had a huge argument with the guy from...
  20. Replies
    18
    Views
    1,115

    I don't care for dye for a few reasons. One is...

    I don't care for dye for a few reasons. One is guys always use way to much. Once you do find the leak how easy is it to clean all that up so the next guy doesn't think it's leaking. Another never use...
  21. Replies
    48
    Views
    2,432

    That's because it doesn't strip away aluminum...

    That's because it doesn't strip away aluminum like other coils. Ever see a rooftop condenser look like tinsel on a christmas tree. I have it's from years of acid cleaning
  22. Replies
    29
    Views
    1,098

    If no chart I usually try to get it between 12-17...

    If no chart I usually try to get it between 12-17 superheat and 5-13 subcooling. Temperature drop across coil helps as well
  23. Replies
    24
    Views
    1,426

    When people start yelling about the last guy, and...

    When people start yelling about the last guy, and how he always takes care of them by filling the system up with freon,blah blah blah I wait till their rant is over and I say this.
    If your car...
  24. Replies
    44
    Views
    1,514

    The pressure switches on refrigeration work on...

    The pressure switches on refrigeration work on pressure. Low pressures I usually see are 25 psi. Some are auto reset some are manual. Personally I like manual reset. Something happened to make it...
  25. I use scheduled 40 pvc and the trap is done the...

    I use scheduled 40 pvc and the trap is done the way poodle mike said about the inlet being taller than the outlet. Condensate seems like a simple thing but can cause thousands of dollars in damage if...
Results 1 to 25 of 76
Page 1 of 4 1 2 3 4