Search:

Type: Posts; User: firecontrol

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    29
    Views
    2,307

    I thought it looked like soaking wet particle...

    I thought it looked like soaking wet particle board. hmmm
  2. Did you happen to read the installation manual...

    Did you happen to read the installation manual for the furnace? It should be explained in there how each different kind of equipment arrangement should be wired.
  3. What are you using to measure the humidity? And...

    What are you using to measure the humidity? And are you using it to measure both the lower and upper floors?

    Are the lower and upper floors of the home closed off from one another? I ask because...
  4. Replies
    4
    Views
    163

    The limit should not be in contact with the heat...

    The limit should not be in contact with the heat exchanger. With what you found with the fuse I would be suspect of everything in that unit. Make sure the limit that is installed is in fact the...
  5. Replies
    5
    Views
    385

    Bag filters

    Bag filters
  6. Replies
    6
    Views
    346

    X2

    X2
  7. The SP #'s you are reporting tell the whole...

    The SP #'s you are reporting tell the whole story. The zones are not sized properly for the capacity of at least the AC part of the system.

    The carrier zoning does not use a bypass/dump damper...
  8. So you and your contractor has identified that if...

    So you and your contractor has identified that if zone 2 is partially open there is no whistling. But to try and solve the problem (it whistles) when it is closed he's trying to seal it tighter? I...
  9. Replies
    8
    Views
    345

    What you are experiencing is the fact that one...

    What you are experiencing is the fact that one size does not fit all situations. The unit "sounds" like it is correctly sized for your hottest days in which it will run longer cycles. Longer cycles...
  10. Replies
    1
    Views
    160

    The round pipe looks to be old. I say that...

    The round pipe looks to be old. I say that because the tape on the joints looks a lot like the old asbestos type that used to be installed.

    They possibly could be replaced by rectangular...
  11. Replies
    11
    Views
    639

    From here it sounds like (possibly) your...

    From here it sounds like (possibly) your contractor, for whatever reason, is in a bit over his head. If they are willing, ask them to call in a technical representative from where he brought the...
  12. Replies
    3
    Views
    276

    You have a warranty that Amana puts on it's...

    You have a warranty that Amana puts on it's equipment to help ensure their customers are satisfied with the product they purchase. Are you satisfied? The same concern for your satisfaction should...
  13. Replies
    8
    Views
    248

    Keep pushing the contractor to get whoever...

    Keep pushing the contractor to get whoever installed the intake to come out and take a look at it. I've heard them do this and the noise usually comes from the damper that is installed "somewhere"...
  14. I seriously doubt that the thermostat had...

    I seriously doubt that the thermostat had anything to do with the AC dying at 25 years old. Did you ask the contractor if he thought it did? It probably was just a untimely coincidence..... like...
  15. Ever hear the saying "If you don't have time to...

    Ever hear the saying "If you don't have time to do it right the first time, you surely don't have time to do it over and over again."? And most customers aren't going to keep handing your company...
  16. Ok, let me play service manager: 1) What were...

    Ok, let me play service manager:

    1) What were your resistance readings on the windings and to ground?
    2) What did the original capacitor measure for the compressor?
    3) What voltage did you...
  17. A cheap mechanical clock, wire it to the pressure...

    A cheap mechanical clock, wire it to the pressure control (the how is up to you) so that the clock gets power when the pump does. Set for 12:00 and the added minutes in the morning will be how long...
  18. Replies
    3
    Views
    269

    Search "hiding line set". The PVC items are used...

    Search "hiding line set". The PVC items are used "normally" for covering line sets outside, but they would be simpler than building something. Most can be painted.
  19. Replies
    4
    Views
    293

    Building inspectors have the last say on what...

    Building inspectors have the last say on what needs to be done. If you're being told something has to be done, but aren't sure why, ask them nicely if they could give you a copy of the exact code or...
  20. In 30 years I've never had anyone question...

    In 30 years I've never had anyone question whether or not I actually put in the amount of refrigerant that I said I did. Now, is that due to the fact that I always use a scale or is it that I have...
  21. Pictures of your boiler system would be good. As...

    Pictures of your boiler system would be good. As the saying goes they can be worth a thousand words. Don't get to close (include floor to ceiling shots to get all piping etc.) and take them from...
  22. I would suggest starting with having someone...

    I would suggest starting with having someone assess the attic insulation/ventilation. Upper floor temperatures can be greatly affected by lack of attic insulation and venting.

    To get a reasonable...
  23. If you're talking about an air conditioning...

    If you're talking about an air conditioning system for cooling, keep in mind that the air conditioning requires X amount of air flow when cooling the home (the outdoor unit is running).
  24. First thing is you do not want to use the same...

    First thing is you do not want to use the same heat source/water to circulate through radiators and coming out of your hot water faucets..... if that's what you were saying. The contamination...
  25. What size (capacity in btu's/hr) was the old one...

    What size (capacity in btu's/hr) was the old one and what size is the new one?