  1. Replies
    36
    Views
    785

    how did you figure it out?..

    how did you figure it out?..
  2. Replies
    6
    Views
    169

    so it has a leak then...

    so it has a leak then...
  3. Replies
    11
    Views
    360

    exactly this

    exactly this
  4. we don't bother rebuilding those pumps.. we just...

    we don't bother rebuilding those pumps.. we just replace with oem part
  5. Replies
    36
    Views
    632

    We all carry a pager when we're on call

    We all carry a pager when we're on call
  6. what?....

    what?....
  7. Replies
    13
    Views
    406

    How do mean built in?..is it running inside the...

    How do mean built in?..is it running inside the panels of the cooler up to the evap? If so yea what kamp said... Run new cap tube and suction line down the back of unit. Tape the cape tube to it...
  8. I just got the h10 pro. I actually used it the...

    I just got the h10 pro. I actually used it the other day on the Lennox 15 ton (different post) and my detector didn't pick up sh1t ...bubbles , and I found the leaks...
  9. Replies
    24
    Views
    668

    i imagine thats just some kind of degreaser...

    i imagine thats just some kind of degreaser ....the easy off.
  10. Replies
    24
    Views
    668

    nu brite aerosal (blue can) for the real greasy...

    nu brite aerosal (blue can) for the real greasy ones. spray coil with hot water get all loose shyte off. then foam her up, wait five minutes , rinse with hot water, repeat until you can see through...
  11. Thread: Call

    by northeastbeast
    Replies
    7
    Views
    345

    good call :cheers:

    good call :cheers:
  12. Replies
    16
    Views
    676

    yea i have seen that somewhere on here before

    yea i have seen that somewhere on here before
  13. Replies
    3
    Views
    397

    reason i know is because we installed a bunch of...

    reason i know is because we installed a bunch of those for a paint store chain a few years ago..
  14. Replies
    3
    Views
    397

    its a bay web brand stat. there should be a...

    its a bay web brand stat. there should be a module btween stat and unit it controls so wifi capabilities can be used for monitoring or control.
  15. Replies
    20
    Views
    1,011

    i don't clean fittings when brazing copper... i...

    i don't clean fittings when brazing copper...
    i do when soldering
  16. Replies
    23
    Views
    955

    thats crazy!. we had a similar issue with a...

    thats crazy!. we had a similar issue with a fujitsu except we never tried dye, but i did conclude the leak was in the indoor section . i never could pinpoint it with my detector..... or bubbles on...
  17. Replies
    12
    Views
    626

    we always replace with virgin refer , for all...

    we always replace with virgin refer , for all types of repairs not just compressor burn outs, company policy...
  18. Replies
    10
    Views
    542

    why bother going back?? :grin2:

    why bother going back?? :grin2:
  19. do you have to clean fittings and flux with...

    do you have to clean fittings and flux with staybrite?
  20. i was taught to braze refrigeration lines... i...

    i was taught to braze refrigeration lines... i thought it was standard practice...in all honesty i think its probably easier too. don't you have to clean fittings and flux with staybrite?
  21. Replies
    4
    Views
    461

    One place we do work at has a cooler with one of...

    One place we do work at has a cooler with one of those evaps too lol. Only one I've ever seen
  22. is this a trick question?.. why not just test the...

    is this a trick question?.. why not just test the contacts to see ifs working..
  23. Replies
    32
    Views
    1,519

    flared connections, no brazing needed. unless you...

    flared connections, no brazing needed. unless you happen to kink the line while running it.
  24. Replies
    23
    Views
    1,208

    10 or 15 is too short of an ice cycle. its...

    10 or 15 is too short of an ice cycle. its typically around 30 mins for the KM models, tech manual will tell you exactly what to look for
  25. Replies
    0
    Views
    647

    york predator roof top

    can anyone tell me what gas pressure I'm looking for with propane on these units. high and low fire...
  26. we have some smaller shops around here where 10 a...

    we have some smaller shops around here where 10 a dozen is legit, as long as the donuts are bomb digitty :grin2:
  27. Replies
    19
    Views
    1,109

    this is exactly how we do it too.

    this is exactly how we do it too.
  28. Replies
    65
    Views
    4,360

    we get time and a half plus holiday pay , but we...

    we get time and a half plus holiday pay , but we have to work 40 before OT no matter holiday or not...
  29. Replies
    6
    Views
    1,215

    liquid tight

    something i saw sitting outside a convenient store eating lunch one day.
    537991
  30. Replies
    65
    Views
    4,360

    thats messed up

    thats messed up
  31. Replies
    10
    Views
    978

    oh really? so the the unit will still use...

    oh really? so the the unit will still use electric heat when the heat pump can't keep up with just the heat pump dip switch on.
  32. Replies
    10
    Views
    978

    what do you mean heat switch? it has dip switch's...

    what do you mean heat switch? it has dip switch's on the board. you can select electric heat, heat pump etc...
  33. Replies
    10
    Views
    978

    islandaire PTAC

    we have a hotel with all islandaire ptac's under a year old and so far a bunch have been having issues. today i worked on two separate units which appear to have bad boards. both units are acting...
  34. Replies
    10
    Views
    2,316

    LOOKs like the condensate trap is sideways

    LOOKs like the condensate trap is sideways
  35. Replies
    15
    Views
    1,187

    im a service tech for a company that does...

    im a service tech for a company that does commercial refrigeration, heating and air conditioning. i have to say, i really like my job. i would recommend commercial as opposed to residential. you get...
  36. cap tube

    cap tube
  37. Replies
    31
    Views
    2,553

    the H-10 I have is a rechargeable battery its...

    the H-10 I have is a rechargeable battery its been super effective . I'm two years into the service trade and the h-10pm was supplied in the truck all the guys i work with have them. after a few...
  38. if that unit is sitting on the ground ( which it...

    if that unit is sitting on the ground ( which it looks to be) it doesn't really matter, there is no chance of it overflowing the pan and leaking into the structure
  39. Replies
    22
    Views
    3,254

    yeeehaw! cha ching cha ching$$. thats the sound...

    yeeehaw! cha ching cha ching$$. thats the sound of their wallet :yes:
  40. Replies
    12
    Views
    1,047

    I don't know. I was confused and thats why i...

    I don't know. I was confused and thats why i posted this thread. maybe i messed up somewhere not sure...
  41. Replies
    12
    Views
    1,047

    its a package unit so its weighed in charge. my...

    its a package unit so its weighed in charge. my first thought was it was a little low on gas but why would my SST be higher than what it should be? and compared to the other unit on the roof...
  42. Replies
    12
    Views
    1,047

    thats a good idea i didn't think of that.

    thats a good idea i didn't think of that.
  43. Replies
    12
    Views
    1,047

    SST was 55f which i also thought was high....

    SST was 55f which i also thought was high. superheat was 30 degrees so if valve was wide open then that wouldn't have been the case. and yes it was hot inside building.
  44. Replies
    12
    Views
    1,047

    txv troubleshooting

    Need some pointers on.the subject. Went to.a call.last week unit has high.superheat 30 and 9 degrees sub cool. Sst was 55 and head pressure was around 350 with a 90 degree ambient. R410a. I condemed...
  45. my thoughts exactly

    my thoughts exactly
  46. one p trap just wasn't good enough, i guess...

    my coworker installed this last week and i got a call today (sunday) because water was leaking into the ceiling and onto the floor. he claimed he didn't remember what store it was but he knew he made...
  47. hoshizaki and i believe manitowoc offer factory...

    hoshizaki and i believe manitowoc offer factory training schools that are like a week long in some facility where you work on machines and learn all diagnostics and such. not cheap though
  48. Replies
    6
    Views
    489

    thanks !

    thanks !
  49. Replies
    6
    Views
    489

    yes I've installed numerous mini splits. Im a...

    yes I've installed numerous mini splits. Im a tech notice the "professional member" tag under my name...? never been the one who does a site visit and calculation thats why i was asking how to go...
  50. Replies
    6
    Views
    489

    sizing a mini split

    How do i go about sizing a mini split for a house? my fiancees parents are thinking about putting one in their house and they asked me if i wanted to make some extra money installing it for them. i...