  1. MPCTH3500‏ from Honeywell is probably what i will...

    MPCTH3500‏ from Honeywell is probably what i will end up with. its looks to be some kind of custom controller. not in there catalog.
    It has 2 setpoints on for temp the other for humidity. and it has...
  2. I dont think the TH8321 would work for me.

    I dont think the TH8321 would work for me.
  3. I did not know that the vision pro had modulating...

    I did not know that the vision pro had modulating output.
    Just have to DL and manual and read up on one.
  4. Looking for modulating thermostat to control temperature and humidity

    Is there any thermostats that have 2 inputs (one for humidity the other temperature)?

    I am trying to control temperature as well as humidity in a large swimming pool.

    My system only has a...
  5. Replies
    20
    Views
    1,649

    im using a blower motor to replace a blower...

    im using a blower motor to replace a blower motor. the picture of a condenser was just an example of how to attach a picture.
  6. Replies
    20
    Views
    1,649

    Thanks guys, so much more helpful than the tech...

    Thanks guys, so much more helpful than the tech support person from the company that makes the motor.
    He said to me that motor line was sold and changed names 3 times and he has no further details....
  7. Replies
    20
    Views
    1,649

    say whaaa?

    say whaaa?
  8. Replies
    20
    Views
    1,649

    I bought the motor at Trane for a cadet type...

    I bought the motor at Trane for a cadet type heater. The unit im working on does not have a speed selector switch.
    my big concern is why do they show on the right side of the picture, RD/BK and...
  9. Replies
    20
    Views
    1,649

    OK, thanks i got the pic to load. OK, now that...

    OK, thanks i got the pic to load.
    OK, now that you all can see the picture, I will repeat my question.
    in the picture it looks like they made a mistake in regards to the drawing of the switch.
    If...
  10. Replies
    20
    Views
    1,649

    [QUOTE=rcstl;21530761]In "go advanced" page down...

    [QUOTE=rcstl;21530761]In "go advanced" page down to manage attachment, after you upload the image in manage attachments, and the picture is in the lower section, click insert inline and then done.
    ...
  11. Replies
    20
    Views
    1,649

    https://plus.google.com/photos/1013184651895768439...

    https://plus.google.com/photos/101318465189576843919/albums/6203052947425078769
    hopefully this image will work.
  12. Replies
    20
    Views
    1,649

    Schmatic question

    I think this wiring diagram on the side of the motor is wrong.
    Can someone look at the right side of the picture and tell me if they see something wrong please.

    ps, not sure if my attachment...
  13. Replies
    4
    Views
    759

    i know we have ADS, not sure if we have adx

    i know we have ADS, not sure if we have adx
  14. Replies
    4
    Views
    759

    Upgrade from Metasys?

    We have 7 BLDGs that's running Metasys ver 5.

    We have a conflict with Java running computers and were asked to upgrade to ver 7.
    according to our JC rep, version 7 has a launcher software that...
  15. that was one of my options. I ended up just...

    that was one of my options. I ended up just ignoring the amps after the VFD and going with the amperage before the VFD.
    Motor is running fine, amps are at RLA.
  16. You are correct. they maxed it out at 53 HZ to...

    You are correct. they maxed it out at 53 HZ to keep the motor from exceeding its RLA rating.
  17. I ended up not buying the fluke 289 to many beans...

    I ended up not buying the fluke 289 to many beans for this tool budget year.
    I did recheck the motor amp before the VFD and it was great, rated for 6.2 actual was 6.1 ish
  18. I know the VFD is password protected and the...

    I know the VFD is password protected and the manufacturer would not give us the code. I am hoping I can at least read the info from it.
    Problem is, with a motor drawing 3 times the normal...
  19. I may pick up the Fluke 289 combo kit tomorrow....

    I may pick up the Fluke 289 combo kit tomorrow. that has high and low pass.

    Ok, can someone tell me what amps I should see (using the correct meter on the load side of the VFD)at 30 hz with a...
  20. Jayguy, if I did have a good clamp on what kind...

    Jayguy, if I did have a good clamp on what kind of amps should I see?
  21. I was thinking I'd pick up a better meter tomorrow

    I was thinking I'd pick up a better meter tomorrow
  22. I have a 6 amp motor running 18 amps measured after the VFD

    New motor just installed. checked amps at the motor and was reading 18 amps. nameplate is 6 amps at 480 volts. 3 phase.

    The VFD was at 52 HZ (was unable to bypass or set to 60 HF)
    Normally I...
  23. in some of the pictures i seen in a armstrong...

    in some of the pictures i seen in a armstrong catalog the horizontal coils the header looked much different. the outlet was slightly lower and smaller then the inlet.
    Hard to tell from the picture...
  24. Fan is under the coil. I can see the coil from...

    Fan is under the coil. I can see the coil from top and bottom. coil looks flat. no slope in coil nor header.
  25. yes it is.

    yes it is.
  26. I have some new information. Looks like the...

    I have some new information.

    Looks like the original assessment was incorrect.

    When the system "locks up", we were going by the dial thermometer located 1 foot below the coil on the edge of...
  27. I thought of extending the air vents as well. I...

    I thought of extending the air vents as well. I will end up doing that in the near future.
  28. BEEN THERE DONE THAT! :grin2:

    BEEN THERE DONE THAT! :grin2:
  29. Hi Cledus, I am still waiting to see how many...

    Hi Cledus, I am still waiting to see how many days it can go before it fails.

    after installing the 2 air vents, It stopped working again. so after screwing around with it for a while, I put it...
  30. LOL yes they are! over 400 each. I ended up...

    LOL yes they are! over 400 each. I ended up buying some cheaper ones that did not work for me. some Armstrong m# TS-2. its not what I wanted but the sales guy told me they'd work great.
    I found that...
  31. work still in progress guys. I installed 2 air...

    work still in progress guys.
    I installed 2 air vents and they did not fix the problem.
    I ended up cracking loose one of the air vents (the one I installed on the top of the steam trap) to get it to...
  32. I did not Buford. its a F n t type

    I did not Buford. its a F n t type
  33. " i don't know how, whatever you have installed...

    " i don't know how, whatever you have installed on the steam header is configured, so if it is similar to what is on the condensate, have him bring along a rod that will fit through the pipe it is...
  34. Cledus, I am looking into the vent / breaker you...

    Cledus, I am looking into the vent / breaker you suggested. Could you tell me why I would want to introduce more air into the system with a vac breaker?
  35. Cledus, I have very little experience with steam....

    Cledus, I have very little experience with steam. I have been in the HVAC tech for 30 years. (Warmer climates). Even tho I dont know **** about steam, I seem to be the only one so far that may have...
  36. Well, I may have found our answer.or at least a...

    Well, I may have found our answer.or at least a strong clue.
    This morning was the first morning where the problem did not occur, the operator did not have to drain the water out.
    last night was...
  37. you will be able to tell if the header was design...

    you will be able to tell if the header was design for horizontal operation? I cant even see the header.
  38. I find it interesting that still no one thinks a...

    I find it interesting that still no one thinks a contractor installed a vertical coil in a horizontal position.
    Even tho every part has been changed (after this last coil was installed) and the...
  39. don't you need to know the brand?

    don't you need to know the brand?
  40. Well, we know its not all steam in there lol. the...

    Well, we know its not all steam in there lol. the way I look at it, its either full of water or a lot of air.
  41. I did 2 things differently recently and got some...

    I did 2 things differently recently and got some interesting results.

    1. while the system was still functioning, I closed the hand valve to the air handler and waited till the discharge temp...
  42. I have done it many times, BBeerme. When I open...

    I have done it many times, BBeerme. When I open the valve at the strainer it works almost as good as when we do it in conjunction with closing the hand valve coming into the air handler. Lots of...
  43. the silver thing is a air vent. there was a vac...

    the silver thing is a air vent. there was a vac breaker before the coil (after the heating valve) but I removed that yesterday.
  44. I am doing a test tonight. Earlier I cracked open...

    I am doing a test tonight. Earlier I cracked open the fitting on the top left side of the steam trap. I will check it tomorrow morning to see if it helped.
    I am hoping if there is air trapped...
  45. we are in Oregon Poodle

    we are in Oregon Poodle
  46. I removed the vac breaker a few hours ago. The...

    I removed the vac breaker a few hours ago.
    The reason I did this was of what I observed earlier today.
    The unit was heating properly when I decided to close the hand valve before the heat valve,...
  47. To be clear, I believe the problem is there's...

    To be clear, I believe the problem is there's steam instead of water at the trap.
    the design and location of the coil + that reducing elbow leaving the coil is causing water to hang up in the coil....
  48. I dont recall saying it comes out in a trickle. I...

    I dont recall saying it comes out in a trickle. I did mention when the hand valve before the coil is closed it takes it time coming out i think.
    like i said earlier, i will try and take a video of...
  49. I think you might be asking for something that...

    I think you might be asking for something that has been tried a few times.
    You want me to ask the operator to only open the hand valve at the strainer until only steam comes out, yes?
    if so, he...
  50. I believe what is happening is water is stuck...

    I believe what is happening is water is stuck inside the coil and only steam is leaving the coil causing the trap to shut down. the way the operator gets it to work each morning is to close the hand...