Search:

Type: Posts; User: fire-parts

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    663

    There is a universal Honeywell thermocouple that...

    There is a universal Honeywell thermocouple that comes with a bunch of different parts. It has metric adaptors but it is a little pricey
    ...
  2. Waterford was purchased by Fireplace Products...

    Waterford was purchased by Fireplace Products international (better known as Regency fireplaces). Regency stopped making them but they would be the best people to talk to regarding the parts.
  3. Replies
    3
    Views
    1,091

    Sounds like the unit might be turning on and off...

    Sounds like the unit might be turning on and off quickly causing gas to build up and boom. Check loose wiring or bad switch
  4. Replies
    2
    Views
    1,598

    That is a mercury switch. They are not field...

    That is a mercury switch. They are not field serviceable and no longer available.
  5. Agree with talktowags. The only way to get the...

    Agree with talktowags.
    The only way to get the heat into the whole house is using the furnace duct system. Just make sure not to de-pressurize the room with the stove in it too much that it smokes...
  6. I agree with Hearthman, I would check the glass...

    I agree with Hearthman, I would check the glass seal as pretty much every old red silicone gasket glass is shot by this time. If it is still the red silicone gasket I would recommend changing it even...
  7. Thread: Gas Line

    by fire-parts
    Replies
    4
    Views
    710

    Your pipe sizing also depends on gas pressure. If...

    Your pipe sizing also depends on gas pressure. If its a 1/2 pound (low pressure) or a 2lb (high pressure gas meter). All appliances run on low pressure so if your house is high pressure you will see...
  8. Replies
    3
    Views
    1,107

    There are no efficient see-through inserts. The...

    There are no efficient see-through inserts. The only way to get efficiency is to put in a normal single sided insert on one side.
  9. Replies
    3
    Views
    915

    Things like burners are made by the manufacturer...

    Things like burners are made by the manufacturer and the only place to get it is from the manufacturer.
    Online you can get replacement parts like valves, switches, ect. because the manufacturer (in...
  10. Replies
    6
    Views
    1,205

    Technically speaking, you should only use a vent...

    Technically speaking, you should only use a vent kit that is tested and approved for the exact fireplace model you are installing.
  11. Replies
    6
    Views
    1,205

    If you do put two lengths together, make sure to...

    If you do put two lengths together, make sure to seal the joints with a high temperature sealant like this- ...
  12. Replies
    5
    Views
    1,861

    Either the solenoid on the valve isn't working,...

    Either the solenoid on the valve isn't working, or it is working and you just can't see the difference between hi and low. Sometimes, on some units, it can be hard to see the flame difference.
    You...
  13. Replies
    5
    Views
    1,087

    Here is a better picture of that SIT pilot. It...

    Here is a better picture of that SIT pilot. It looks like it will replace the PSE pilot exactly
  14. Replies
    5
    Views
    1,087

    This SIT pilot assembly might work...

    This SIT pilot assembly might work
    http://www.fire-parts.com/replacement-parts/pilot-assemblies/sit-side-mount-pilot-assembly.html