01-07-2013, 07:05 PM
- Replies
- 22
- Views
- 1,440
Thank you. Actually I never heard about that term...
Thank you. Actually I never heard about that term "water hammer". But now I'm know it.
Thank you, I got it. -
01-04-2013, 11:36 PM
- Replies
- 22
- Views
- 1,440
Dear desert guy, I'm forgot what the reading at...
Dear desert guy,
I'm forgot what the reading at pressure gauge. I'm always use that pressure sensor with max pressure is 300psi.
Dear Nuclrchiller
What is water hammer ? Can you explain... -
01-03-2013, 06:36 PM
- Replies
- 22
- Views
- 1,440
Hi guy, I'm using this type of sensor...
Hi guy, I'm using this type of sensor http://www.dwyer-inst.com/Product/Pressure/SinglePressure/Transmitters/Series626-628
Before this I'm never use "pigtail". But some site that use this sensor got... -
01-03-2013, 11:34 AM
- Replies
- 22
- Views
- 1,440
Thank you for the link and info. Dear...
Thank you for the link and info.
Dear Nuclrchiller,
I'm also afraid without "pigtail" will be damaged the sensor. This sensor will be use for control VSD pump. Maybe the best choice is to... -
01-02-2013, 10:16 PM
- Replies
- 22
- Views
- 1,440
Is it without "pigtail" will be effect for the...
Is it without "pigtail" will be effect for the water pressure reading? For information, this water pressure is to control VSD pump.
-
01-02-2013, 09:23 PM
- Replies
- 22
- Views
- 1,440
Water Pressure Sensor transmitter installation
Hi expert forumer,
I need advice to install water pressure transmitter at Chiller water pipe, I have two option to install whether to use copper tube or not. Please refer to image attachment for... -
01-02-2013, 09:15 PM
Thread: Need Advice to place Pressure Sensor
by azka- Replies
- 15
- Views
- 1,391
Thank you Exwtk, I understand it the function to...
Thank you Exwtk, I understand it the function to control it.
-
10-17-2012, 02:06 AM
Thread: Control Strategy for AHU OT Room
by azka- Replies
- 2
- Views
- 605
Sir, Only 2 DDC involve in this OT Room. Both...
Sir,
Only 2 DDC involve in this OT Room. Both DDC cannot share information to each other. One DDC control the heater to maintain Humidity and the other DDC control the Valve to maintain the... -
10-16-2012, 10:28 PM
Thread: Control Strategy for AHU OT Room
by azka- Replies
- 2
- Views
- 605
Control Strategy for AHU OT Room
Hi,
I'm got some question regarding to Operation Theater (OT) Room control strategy.
Is it possible this control strategy :-
Room Humidity - Control by other controller ( standlone DDC )... -
01-18-2012, 07:51 PM
Thread: Need Advice to place Pressure Sensor
by azka- Replies
- 15
- Views
- 1,391
Thank you for clear explanation, I think that...
Thank you for clear explanation, I think that take a lot of time to tuning the PID for VSD and valve :(
-
01-18-2012, 03:46 AM
Thread: Need Advice to place Pressure Sensor
by azka- Replies
- 15
- Views
- 1,391
Thank you for suggestion, xarralu and crab...
Thank you for suggestion, xarralu and crab master.
my mistake for Delta T.
So, Delta T for control bypass and Delta P for control Variable Speed Drive Pump. May I know why need to place the sensor... -
01-16-2012, 12:09 PM
Thread: Need Advice to place Pressure Sensor
by azka- Replies
- 15
- Views
- 1,391
Need Advice to place Pressure Sensor
Hi expert forumer,
I'm beginner in control automation. I'm need some advice from all of you regarding to this
1) which is best location to place water pressure sensor to control Variable Speed... -
08-03-2010, 08:44 PM
Thread: DDC Software/Hardware Suggestions
by azka- Replies
- 19
- Views
- 2,196
Im working with ASI Control devices. The devices...
Im working with ASI Control devices. The devices running with software and hardware that easy to configure. The hardware can be interface with all type of binary input/output and also analog output....
-
07-25-2010, 08:20 PM
Thread: Small building BacNet system vendor choices
by azka- Replies
- 10
- Views
- 1,363
For small building, use only standalone networks...
For small building, use only standalone networks thermostat. that reduce the cost.
bacnet is not good choice for me. better use OPC server for equipment.
im suggest this equipment to interface...