  1. Replies
    20
    Views
    2,574

    Does anybody have the SB # for this problem? I...

    Does anybody have the SB # for this problem? I have an older TSC120A3R0A29 S/N 705100418L that has both headers at the evap coil plugged. I was going to install TXV's on both circuits but if this...
  2. With a 25* split I would be checking static, that...

    With a 25* split I would be checking static, that points to low airflow across the coil. It looks like the return is pretty much free draw. That would mean the supply duct is undersized for the...
  3. Like every one else has said, you need to get...

    Like every one else has said, you need to get that ductwork fixed. Going to a 4 ton is not going to do you any good with the existing ducts.
  4. The 4 ton does match with that air handler...

    The 4 ton does match with that air handler (AHRI#5720611).

    I would have them back out to verify the system charge and get a temp split across the air handler, that will let you know if it's the...
  5. Replies
    47
    Views
    7,978

    Installed this stat in my home this afternoon. ...

    Installed this stat in my home this afternoon. Easy set up, no frills wifi stat that is priced right.
  6. Replies
    16
    Views
    1,513

    No code that I'm aware of. We always install a T...

    No code that I'm aware of. We always install a T before the trap and cap it, then a vent after the trap with a threaded coupling so we can plug it when cleaning. Most cleanings we use only the shop...
  7. Replies
    16
    Views
    1,513

    With out a regulator to step down the pressure...

    With out a regulator to step down the pressure you could be as high as 2500 PSI straight out of the tank when full.
  8. If the replacement board is the most recent...

    If the replacement board is the most recent version the thermostat has to have update 2.1 installed to allow them to communicate. They will not recognize each other without the update.
  9. If the latest firmware update has not been...

    If the latest firmware update has not been downloaded to the thermostat I would try that next. I have yet to have an issue with an XL950 thermostat that wasn't solved by installing the latest update.
  10. A control board in the TAM8 was updated and the...

    A control board in the TAM8 was updated and the current 950 stats were not compatible with that board.

    I was told that they have a fix and that it just needed to be executed.
  11. Same as what Dave here has said, I have never...

    Same as what Dave here has said, I have never talked with our FSR outside of the training classes.
  12. I did not know that it would flow properly in one...

    I did not know that it would flow properly in one direction but could be restricted the other.

    Learn something new every day.
  13. I wouldn't expect a restricted filter/drier in...

    I wouldn't expect a restricted filter/drier in the outdoor unit due to his statement that the system works correctly in heat.
  14. Its working in heat and in cool your liquid line...

    Its working in heat and in cool your liquid line temp is 5* below outdoor ambient I would lean towards a bad indoor TXV. You're stacking liquid refrigerant in the condensing unit and liquid line.
    ...
  15. Replies
    10
    Views
    976

    If the load came out to be between a 3.5 and 4...

    If the load came out to be between a 3.5 and 4 ton and was in my house I would go with the 4 ton system.

    If the budget can handle it I really like the 2 speed systems.
  16. Replies
    10
    Views
    976

    Did either of the contractors perform a manual j...

    Did either of the contractors perform a manual j load calculation to come up with their equipment sizing?

    The 2 speed would likely be a 4 ton. I'm not a Bryant dealer but I believe the 2 speeds...
  17. If your extended warranty is backed by the...

    If your extended warranty is backed by the factory it may still be good provided that you can find another Tappan dealer in the area.

    It does sound like you may still have a refrigerant leak...
  18. Replies
    12
    Views
    1,666

    Also have and like Wintac, what problems are you...

    Also have and like Wintac, what problems are you having?
  19. Replies
    10
    Views
    1,771

    PM sent

    PM sent
  20. There is an optional relay panel that allows the...

    There is an optional relay panel that allows the use of communicating thermostats with the TAM7 air handlers. Your system will work just fine the way it is. You lose a few features of the 20i and a...
  21. Replies
    10
    Views
    1,771

    The TAM7 is non communicating and requires the...

    The TAM7 is non communicating and requires the additional relays. Just installed a TAM8 with a 4TWZ0048 on Tuesday, customer didn't opt for the 950 stat though.
  22. Replies
    34
    Views
    2,103

    When I have searched by the owners name it shows...

    When I have searched by the owners name it shows me all properties in the county owned by them.

    From there I would just open the file associated with each address and find the one that listed a...
  23. Replies
    34
    Views
    2,103

    If you have access to the Property Appraisers...

    If you have access to the Property Appraisers website you could do a property search under the owners name. Check any property listing under his name for the one that lists a Homestead Exemption (If...
  24. Replies
    12
    Views
    3,681

    Have a few Fujitsu condensing units and air...

    Have a few Fujitsu condensing units and air handlers for sale. No complete systems, all R-22 equipment never installed, still crated.

    SOLD - AOU12R1A Heat Pump condenser (matches with ASU12R1A...
  25. Replies
    15
    Views
    2,033

    The low voltage wiring needs to be ran properly...

    The low voltage wiring needs to be ran properly for starters. Trane has sent out bulletins stating inadequate gaskets on some units and has spelled out exactly how to remedy the situation in the same...
  26. Replies
    14
    Views
    3,033

    They also have a 5 year warranty and are made in...

    They also have a 5 year warranty and are made in the USA.

    I haven't had any cost complaints since I started pointing this out.
  27. Replies
    15
    Views
    1,295

    It's certainly not intentional, but the way that...

    It's certainly not intentional, but the way that showers move through here in the summer time it's unavoidable.

    Many times I have been working under a blazing sun only to have our famous 5 - 15...
  28. Replies
    15
    Views
    1,295

    With the exception of not knowing about the...

    With the exception of not knowing about the grounding strap I would classify it as damn near bullet proof.

    It hangs on the rack with my analogs and gets no special treatment. They are used daily...
  29. Replies
    16
    Views
    1,711

    Use the grounding strap. The original one that I...

    Use the grounding strap. The original one that I bought did not have this and a static discharge took out my temp sensors. The strap is to prevent this.

    It was taken care of by Testo with no...
  30. Replies
    15
    Views
    1,295

    They felt that it was a static build up due to...

    They felt that it was a static build up due to liquid refrigerant flowing through the hoses and that when it discharged it took out the temp sensor ports. The screen quickly shut off then back on. ...
  31. Replies
    15
    Views
    1,295

    WOW, got a call from Jim @ Testo within 5 hrs of...

    WOW, got a call from Jim @ Testo within 5 hrs of this post explaining what likely happened, explaining what they have done to fix the issue, and assuring me that everything will be taken care of.
    ...
  32. Replies
    15
    Views
    1,295

    Testo 550 problem

    The unit will not allow me to switch between the different temperature modes, it is stuck on saturation temperatures. I have replaced the batteries and tried different temperature clamps and still...
  33. Replies
    23
    Views
    7,467

    If it is at all possible we like to set the...

    If it is at all possible we like to set the condenser a couple feet away from the existing location so that the slab can be poured and allowed to cure for at least 48 hours. When that is not...
  34. Replies
    23
    Views
    7,467

    What is this Fall and Spring that you speak of?

    What is this Fall and Spring that you speak of?
  35. Replies
    23
    Views
    7,467

    New construction gets poured slabs or well built...

    New construction gets poured slabs or well built stands depending on where flood level is, but I have not yet found a customer that will let us disconnect their a/c, pour a slab, the install the new...
  36. Replies
    23
    Views
    7,467

    I tried a Google search for FRCC to take a look...

    I tried a Google search for FRCC to take a look at the pad that you have but came up with nothing. The only one I'm familiar with is the DiversiTech pad. According to the labeling the FRCC would...
  37. Replies
    23
    Views
    7,467

    According to the labeling it has been engineered...

    According to the labeling it has been engineered to meet Florida standards.
  38. Replies
    23
    Views
    7,467

    These are the pads that we use and are approved...

    These are the pads that we use and are approved for use in Florida up to 150 MPH winds. If this is what was installed under your unit you should have no issues.
  39. Replies
    12
    Views
    3,681

    Happy everything worked out for you. Let me know...

    Happy everything worked out for you. Let me know if you need anything else.
  40. Replies
    12
    Views
    3,681

    Have a few Fujitsu condensing units and air...

    Have a few Fujitsu condensing units and air handlers for sale. No complete systems, all R-22 equipment never installed, still crated.

    1 - AOU12R1A Heat Pump condenser (matches with ASU12R1A A/H) ...
  41. Replies
    12
    Views
    3,681

    The 9k and 12k btu units are 115v and the others...

    The 9k and 12k btu units are 115v and the others are 208/230v.

    I believe that they were only 10 or 11 SEER systems. The serial #'s indicate they were manufactured around 2000 or so.
  42. Replies
    12
    Views
    3,681

    R-22 Fujitsu Equipment

    Have a few Fujitsu condensing units and air handlers for sale. No complete systems, all R-22 equipment never installed, still crated.

    1 - AOU12R1A Heat Pump condenser (matches with ASU12R1A A/H) ...
  43. Replies
    29
    Views
    1,777

    Last month we replaced the third coil on a system...

    Last month we replaced the third coil on a system that was installed in 2005. Coil # 4 is an epoxy coated coil that was supplied to us by Trane and should eliminate this issue if it is a problem...
  44. Replies
    22
    Views
    2,955

    Did clean up of a Bingo Hall a few years ago that...

    Did clean up of a Bingo Hall a few years ago that was being converted to a retail outlet.

    Those were the foulest systems I have ever had to attempt to clean.
  45. Replies
    7
    Views
    1,301

    You guys worry to much. What doesn't kill you...

    You guys worry to much. What doesn't kill you only makes you stronger.
  46. Replies
    31
    Views
    7,329

    Trane does have Variable Speed air handlers that...

    Trane does have Variable Speed air handlers that are non communicating, but I don't know why you would install the communicating outdoor with a standard air handler.

    If it met the tax credits it...
  47. Replies
    29
    Views
    1,777

    American Standard/Trane has a program in place...

    American Standard/Trane has a program in place for extended warranty evaporator coil replacements. Any evap coil, regardless of age that is replaced under extended warranty gets sent to the factory...
  48. Replies
    90
    Views
    5,004

    It doesn't look like you will get this resolved...

    It doesn't look like you will get this resolved by adjusting airflow, or even installing a 3.5 ton handler. You really need a load calc done on the house to know what size should have been...
  49. Replies
    100
    Views
    5,908

    Been bit more times than I care to remember. I...

    Been bit more times than I care to remember. I have learned over the years to stay focused on what you are doing while testing a live system.

    My main problem used to be talking on the phone...
  50. Replies
    19
    Views
    1,099

    With a broken leg the coon would not last long in...

    With a broken leg the coon would not last long in the wild. I would put it down and be done with it.

    More humane than leaving it in there.
Results 1 to 50 of 369
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event