    integrated door access controls

    Are there any recommendations for a door access control system that have a Bacnet or Modbus interface? For example, Distech's Bacnet product is a good fit but I'm looking for other products for...
  2. water temperature sensor calibration device

    Hi All -
    We've got a lot of 10K-2 immersion sensors wired to our BMS and need to calibrate these sensors. I have heard of NIST temperature calibration tools that insert through a Pete's Plug and...
  3. Replies
    7
    Views
    1,086

    rockwell automation programming

    Does anyone have recommendations for a group that could do contract Rockwell Automation programming? Thanks.
  4. Replies
    2
    Views
    418

    that's what i was thinking of.. not sure what...

    that's what i was thinking of.. not sure what they are actually worth.
  5. Replies
    2
    Views
    418

    I/A MNL-150, MNL-100

    I have a number of these controllers (and MN-S3 room sensors) that were replaced and the customer doesn't want to bother with them. Any idea what the value of these controllers are?
    Thanks.
  6. Replies
    4
    Views
    733

    haven't seen any specific limitations documented...

    haven't seen any specific limitations documented anywhere in our ALC documentation, or experienced anything similar that wasn't directly attributable to either a problematic database or server...
  7. Replies
    3
    Views
    556

    Thanks. I sent you an email.

    Thanks. I sent you an email.
  8. Replies
    3
    Views
    556

    fault detection & diagnostics

    Does anyone have a recommendation for an AFDD technology/company? Target building(s) are non-industrial, commercial/municipal buildings with standard HVAC equipment and utility metering. Thanks.
  9. Replies
    4
    Views
    981

    That has happened to me when IIS is running on...

    That has happened to me when IIS is running on the WebCTRL server. Turn IIS off in the operating system and make sure that WebCTRL is running on port 80 (it does, by default).
  10. Replies
    5
    Views
    2,455

    for most bacnet MS/TP controllers, the CPU that...

    for most bacnet MS/TP controllers, the CPU that runs the control program also performs network functions. So you can directly measure the slow down effect of network traffic on the CPU with a simple...
  11. Replies
    10
    Views
    1,227

    call automated logic and ask for John Miner. ...

    call automated logic and ask for John Miner. he's the man to speak with regarding new/expanded dealership opportunities.
  12. Replies
    42
    Views
    4,128

    i came from a TAC/JCI/Honeywell environment but...

    i came from a TAC/JCI/Honeywell environment but have deployed ALC for almost five years now. My take is this: if you are more concerned about integration & expandability to other enterprise SCADA...
  13. Replies
    35
    Views
    2,195

    OK, I stand corrected ( i think). I've used...

    OK, I stand corrected ( i think). I've used Lumisys lighting panels in the past and currently BLR (ALC OEM) panels, and they are nearly identical. In fact, I had some surplus lighting relays from...
  14. Replies
    35
    Views
    2,195

    I have an Automated Logic panel sitting in my...

    I have an Automated Logic panel sitting in my office right now. On the bottom in small letters, it says: "Made by Blue Ridge Technolgies".

    I believe this is the company history: Lumisys --> Blue...
  15. Replies
    35
    Views
    2,195

    just dropped two ALC lighting panels directly...

    just dropped two ALC lighting panels directly onto the ARC156 bus yesterday. very fast deployment and integrates perfectly into the head end (equipmentbuilder generated gfx/programs). Can't say my...
  16. Replies
    14
    Views
    1,084

    touch screen (text) interface

    I need a touch screen interface to be located in a common area. A group of offices all have temp sensors wired to an FCU controller, which when averaged together is the "zone temp" process variable...
  17. Replies
    15
    Views
    1,697

    i spent a couple days with one of the principal...

    i spent a couple days with one of the principal writers of this book in omaha and have it in house for our guys to read if they're interested in the basics of interoperable control systems. i'd...
  18. Replies
    8
    Views
    836

    that same functionality has been built into ALC...

    that same functionality has been built into ALC control programs for years... sounds nearly identical. the bas is an integral player in the the load shaving portion of DR because so many of the...
  19. Replies
    23
    Views
    2,912

    how reliable is your information? This is news...

    how reliable is your information? This is news to me and I am an ALC dealer.
  20. Replies
    2
    Views
    524

    nw8000 integration

    I'm looking for ways to integrate ASD devices (MZII, PEM) into a modern protocol network, say Bacnet/MSTP, Bacnet/IP or even XML/SOAP.

    i know there's a tridium asd driver, but what are the other...
  21. Replies
    57
    Views
    4,736

    regarding loytec getting into bacnet despite some...

    regarding loytec getting into bacnet despite some of their key players voicing concerns about it: c'mon. this is corporate america, or in this case corporate austria. this is an era where...
  22. Thread: 1 phase VFD

    by drafty888
    Replies
    9
    Views
    1,471

    1 phase VFD

    Anyone found a good product for varying the speed of a 208vac single phase fan (1hp)? It should respond to 0-10vdc or 4-20ma. Thanks!
  23. Replies
    3
    Views
    1,117

    building dashboards

    Anyone have any product recommendations for building dashboard products, either software or hardware? TIA.
  24. Replies
    8
    Views
    2,286

    ALC has a "room controller" that operates in a...

    ALC has a "room controller" that operates in a stand-alone mode and has multiple AO's and DO's. There's quite a few built-in programs you can select from to optimize the HVAC equipment you're...
  25. Replies
    4
    Views
    824

    you might want to contact steve jones of the s4...

    you might want to contact steve jones of the s4 group. i think he's developed a couple JCI integration solutions.
  26. Replies
    62
    Views
    9,399

    that arrangement has worked out well for ALC and...

    that arrangement has worked out well for ALC and Carrier so far. but comparing Carrier and JCI is not an apples to apples comparison. Carrier had no claim of superior knowledge in controls to...
  27. Replies
    5
    Views
    691

    steam flow meter

    A project i am working on has specified an orifice plate steam flow meter. This setup is comprised of an orifice plate compressed by 150# flanges on an 8" steam pipe. Both up and downstream flanges...
  28. Replies
    109
    Views
    10,833

    exactly what i was querying... thanks. i think...

    exactly what i was querying... thanks. i think that a very slow PID calculation rate (1-2 min or greater), coupled with a small integral value will work here. got to give the VAV boxes enough time...
  29. Replies
    109
    Views
    10,833

    static pressure reset

    Hey guys I wanted to get some feedback on your experiences with duct static pressure reset routines.

    When I am done with the TAB contactor, I'll already have a duct static setpoint that...
  30. temp sensor in steam condensate line/trap

    I have heard that a temperature sensor wired to & properly programmed in a BAS can function in lieu of a freezestat on a steam coil in an AHU.

    I cannot find any calculations or data to support...
  31. Replies
    8
    Views
    844

    sysint, can you email me and I'll reply on my...

    sysint, can you email me and I'll reply on my work account. email address is in my profile. i'll think i'll need 20-25 lgates, but would like to test one first. if there's a better contact person,...
  32. Replies
    8
    Views
    844

    conceptual question about lns: once the config...

    conceptual question about lns: once the config utility has scanned the network and populated a table of mapped points in the lgate, do polled nv requests go to the lns database, or directly to the...
  33. Replies
    8
    Views
    844

    lon nv's --> bacnet objects

    I've got a customer with a large flat lon system (I/A to wonderware via a variety of IP routers) and i need to pick a variety of NV's off the lon network and expose them on Bacnet/IP, without...
  34. Replies
    2
    Views
    501

    Thanks, that's exactly what I was looking for.

    Thanks, that's exactly what I was looking for.
  35. Replies
    2
    Views
    501

    DP across modulating steam valve

    Looking for some sage input on the following...

    25psi inlet steam to a modulating steam valve with a 195 #/hr load. I've calculated this application to require a 3.32cv valve. I can only get a...
  36. Replies
    3
    Views
    450

    numerical read out LED/LCD

    Can someone make a product recommendation for a panel mount device (can be routed into panel door face) that displays a number? The BAS controller driving this device would supply a 0-10vdc signal...
  37. Replies
    262
    Views
    15,215

    that was me, and no my dealership is independent,...

    that was me, and no my dealership is independent, not a branch. find another bone to pick...
  38. Replies
    262
    Views
    15,215

    This, I can answer. My dealership does our own...

    This, I can answer. My dealership does our own floor plans. We all use the same tool (Viewbuilder) to create floor plans, and as long as the base image (.JPG, .PNG, etc) of the floor plan is clean,...
  39. Replies
    3
    Views
    499

    steam flowmeter

    what is the valuable output unit of measurement from a steam flowmeter? I'm looking at a couple different orifice plate and vortex steam flowmeters, and it seems most have a differential pressure...
  40. Replies
    299
    Views
    31,045

    i did some bench testing on a variety of ALC...

    i did some bench testing on a variety of ALC modules (LGR25, M4106, ZN551, RC642D) where the same module was running ARC156 (using the co-processor) and also in MS/TP mode (the main CPU then performs...
  41. Replies
    299
    Views
    31,045

    [QUOTE=ControlBIZ;4527242][QUOTE=drafty888;4526862...

    Apparently I intrepreted your "looks and smells the same" statement differently from how you intended it. Clearly, the Alerton and ALC controllers on the same MS/TP trunk are not programmed with the...
  42. Replies
    299
    Views
    31,045

    [QUOTE=ControlBIZ;4476972] I have yet to see an...

    [QUOTE=ControlBIZ;4476972]
    I have yet to see an ALC contractor install an Alerton or Reliable or KMC VAV controller in an existing system seamlessly and marry it back to the front end so everything...
  43. Replies
    11
    Views
    1,137

    thanks for all the replies. erik, anything...

    thanks for all the replies.



    erik, anything worth noting on Delta's programming tool? Is it GPL or line by line? Any way to view the program "live"? In other words, watch the program working...
  44. Replies
    11
    Views
    1,137

    reliable vs delta

    Anyone have opinions on these two product lines and which is better/worse and why? What are their programming tools like?

    From their websites, it seems like Delta has a better head end and a more...
  45. Replies
    3
    Views
    746

    weather proof air flow switch

    I've got to provide a NEMA3R/4 rated air flow switch on an OA intake to an AHU. The switch is actually a run permissive for an electric snow melt system prior to the AHU. The switch will be...
  46. Replies
    30
    Views
    2,579

    i'd love to see more bacnet/ip controllers. alc...

    i'd love to see more bacnet/ip controllers. alc just came out with one over a year ago. it has no fieldbus connection on it whatsoever.

    are you suggesting that IP should replace serial bacnet...
  47. Replies
    30
    Views
    2,579

    ALC - York Chiller - ABB VFD (MS/TP @ 38.4k) ...

    ALC - York Chiller - ABB VFD (MS/TP @ 38.4k)

    where possible i try to stay away from ms/tp in favor of bacnet/ip integrations. just did one to a very cool AMX home automation system, mitsubishi...
  48. Replies
    18
    Views
    4,036

    The Sitelink isn't affected by ALC's baby core...

    The Sitelink isn't affected by ALC's baby core issue. Only "baby core" modules (ZN, AAR, SE) needed driver updates, and only if they were manufacturered within a specific time window.

    to your...
  49. Replies
    4
    Views
    634

    ah sorry. i take it by the "Pro only sections"...

    ah sorry. i take it by the "Pro only sections" you mean the forum reserved for "Professional Members". I am interested in controls related discussions that might occur outside this public forum. ...
  50. Thread: Tridium

    by drafty888
    Replies
    247
    Views
    14,508

    i am very interested in seeing a rational reply...

    i am very interested in seeing a rational reply to this.

    LON is a full 7 layer OSI protocol; doesn't that mean that LON can't be transported on IP like Bacnet can, unless it's "zipped" or "packed"...