I did one years ago with 3 thermostats and one...
I did one years ago with 3 thermostats and one seven day time clock. Every 12 hrs it switched from one unit to the other. both system tstats were set the same co 35 ci 40. Third tstat was an override...
-
04-25-2013, 07:40 PM
- Replies
- 27
- Views
- 712
You do not have to remove all the refrigerant to...
You do not have to remove all the refrigerant to charge to the sporlan chart. Clear the sight glass first. Then add the refrigerant per the caculations from the chart to add refrigerant needed to...
-
04-15-2013, 10:03 PM
Thread: Looks Home Made
by johndief- Replies
- 5
- Views
- 1,321
Distributors are inexpensive and easy to install....
Distributors are inexpensive and easy to install. Sporlan guy sized it and a txv for me. No reason not to do it right.
-
04-11-2013, 08:46 PM
Thread: Looks Home Made
by johndief- Replies
- 5
- Views
- 1,321
Looks Home Made
Homemade is not always better. This freezer coil was icing up bad at txv. Getting new distributor and
sweat txv. -
03-28-2013, 09:56 PM
Thread: Undersized Glycol Chiller
by johndief- Replies
- 33
- Views
- 821
Some ideas for you I had a walk-in cooler that...
Some ideas for you
I had a walk-in cooler that was used for cooling hams out of a smoke house, was always tripping high head. Installed a CPR valve on it. Solved the problem but took longer to cool... -
Thank you Ice for your help.
Thank you Ice for your help.
-
I looked up the Attron on this site, there was...
I looked up the Attron on this site, there was alot of good information on them. I think what I have is different in that the drop leg is not attached to the liquid header but goes into the top of...
-
It does not look like it is worth the time,...
It does not look like it is worth the time, effort or cost to get working. What was its function? I am sure the
rack would run fine without it. -
Koolsurge
I have a rack with this controler on it, I dont think it is working correctly. Does anyone have any information on this.
-
12-14-2012, 06:31 AM
Thread: International Harvester Freezer
by johndief- Replies
- 5
- Views
- 599
What was the btu capacity of the compressor?
What was the btu capacity of the compressor?
-
12-13-2012, 08:44 PM
Thread: International Harvester Freezer
by johndief- Replies
- 5
- Views
- 599
No other numbers I could see.
No other numbers I could see.
-
12-13-2012, 01:43 PM
Thread: International Harvester Freezer
by johndief- Replies
- 5
- Views
- 599
International Harvester Freezer
A buddy wants a new compressor for his International Harvester freezer the one that is on it is noisy. Mo# 11FC Ser#45842 B8. The problem is that the numbers on the compressor do not come up for...
-
10-31-2012, 01:52 PM
Thread: Does Not Have A leg To Stand On
by johndief- Replies
- 5
- Views
- 1,022
Does Not Have A leg To Stand On
Dre by this all the time, decided to take a picture.
-
10-15-2012, 09:22 PM
Thread: Winter Wonderland
by johndief- Replies
- 6
- Views
- 410
Thanks for you replies. I will look for air...
Thanks for you replies. I will look for air infiltration, i have been focused on a defrost problem.
-
10-15-2012, 12:20 PM
Thread: Winter Wonderland
by johndief- Replies
- 6
- Views
- 410
Winter Wonderland
Any ideas on what is causing this. Hussman display freezer. (2) 5 door sections on one circuit. hot gas defrost. Fans shut down as soon as defrost starts, delay after defrost. Other case on circuit...
-
09-08-2012, 07:08 AM
Thread: Drawer Units
by johndief- Replies
- 2
- Views
- 308
Drawer Units
I have a 1993 vintage cooks line at a Denny's that has 3 cooler drawer sections and 1 freezer drawer section. I need to replace all the drawer fronts and drawer slides but I dont know who made them....
-
08-22-2012, 08:54 PM
Thread: Not for the squeamish
by johndief- Replies
- 4
- Views
- 668
looks just like the food they used to serve us...
looks just like the food they used to serve us when I went to school.
-
08-01-2012, 06:28 AM
Thread: TXV issues on a multi evaporator system
by johndief- Replies
- 9
- Views
- 897
That is what I would do, found a few piping...
That is what I would do, found a few piping issues that way.
-
07-25-2012, 10:47 PM
- Replies
- 12
- Views
- 2,286
I realized she could not afford to pay for the...
I realized she could not afford to pay for the compressor. i felt it was worth the cost of the compressor to end the argument. My point was that some contractors thrive on trying to make everone else...
-
07-25-2012, 08:34 PM
- Replies
- 12
- Views
- 2,286
Some years ago I condemed a compressor on a...
Some years ago I condemed a compressor on a flower cooler at a small shop, it was a couple days after I had changed a condenser motor. Valves were damaged from running without the condenser fan...
-
07-24-2012, 08:12 PM
Thread: Randell Display Case Question
by johndief- Replies
- 9
- Views
- 659
Then I am assuming that you are talking about the...
Then I am assuming that you are talking about the thermostat bulb and you are correct, that would not cause your pressures to be low. To determine that your txv is not working you need to have a no...
-
07-24-2012, 07:50 PM
Thread: Looking For Opinions
by johndief- Replies
- 14
- Views
- 1,354
Here is a picture of these solinoids. Note the 40...
Here is a picture of these solinoids. Note the 40 deg temp differance across the solinoid.
-
07-24-2012, 07:44 PM
Thread: Randell Display Case Question
by johndief- Replies
- 9
- Views
- 659
If you are talking about the bulb for the txv, it...
If you are talking about the bulb for the txv, it should not be insurted in the coil it should be attached to the suction line at the outlet of the evaporator.
-
07-15-2012, 08:22 PM
Thread: Looking For Opinions
by johndief- Replies
- 14
- Views
- 1,354
They are not oem valves. It is a traditional rack...
They are not oem valves. It is a traditional rack with loop piping. The valves are in the compressor room right before yje liqid line go into the pit.
-
07-14-2012, 07:18 PM
Thread: Looking For Opinions
by johndief- Replies
- 14
- Views
- 1,354
There could be other factors that are...
There could be other factors that are contributing to the refrigerant flashing at the solinoids. But at the end of the day if they are not needed and are one of the factors why not take them out....