    Document it and call the local utility. The...

    Document it and call the local utility. The problem with some of these great contracts that come through the doors and no offense meant. But you're price was probably cheap and likely the reason for...
  2. Replies
    8
    Views
    238

    Transformer is before the fuse so I highly doubt...

    Transformer is before the fuse so I highly doubt that the transformer has anything to do with your problem. Look for rubbed wires, run it in every mode/stage while monitoring amperage on fuse. Been...
  3. Replies
    4
    Views
    626

    The fins get real shinny when they are flattened....

    The fins get real shinny when they are flattened. Shinny = clean right?
  4. Replies
    6
    Views
    363

    Here is the Trane chart from the manual, page 82....

    Here is the Trane chart from the manual, page 82.
    https://dl.dropboxusercontent.com/u/52548087/TraneIntellipakSensorResistanceChart.pdf
  5. Replies
    4
    Views
    134

    Dont think anything else will work with that...

    Dont think anything else will work with that sensor. Definitely not 100 ohm. See page 2

    https://www.combustiondepot.com/store/pdf/p_19222.pdf
  6. Replies
    8
    Views
    567

    Acceptable Circuit Protection maybe, just a guess.

    Acceptable Circuit Protection maybe, just a guess.
  7. I see an issue trying to calculate VFD speed...

    I see an issue trying to calculate VFD speed output by monitor timing of the increase or decrease commands outside of the controller that is actually controlling the timing. Will the JACE be capable...
  8. Replies
    8
    Views
    424

    Have used the same one for about 12 years now

    Have used the same one for about 12 years now
  9. Replies
    2
    Views
    163

    Ivu tech tools is for the OPN controllers and...

    Ivu tech tools is for the OPN controllers and Comfortview or Network Service Tool is for the CCN controllers.
  10. Replies
    73
    Views
    2,716

    I have been in the field for many years, far from...

    I have been in the field for many years, far from a hack and have brazed small diameter joints and quick repairs without nitrogen for years. I never recall a call back from a blockage or issues due...
  11. Replies
    17
    Views
    795

    Had issues with multiple units on a roof doing...

    Had issues with multiple units on a roof doing the same thing. Had Carrier rep look at it and their answer was tighten the belts more than what we presently had. It solved the issue, but who knows...
  12. Replies
    36
    Views
    1,625

    Had a jumper fall off R terminal in a brand new...

    Had a jumper fall off R terminal in a brand new York RTU during start up years ago. The other side stayed attached to W1, well the loose end swung right into the line side of the contactor. Big...
  13. Replies
    7
    Views
    1,088

    I have had roofers completely seal condenser...

    I have had roofers completely seal condenser access doors, meanwhile there are two 24 inch fan shrouds on top. Yeah no water will get in there.
  14. Replies
    7
    Views
    1,088

    That must have smelled nice.

    That must have smelled nice.
  15. Replies
    8
    Views
    428

    Correction, someone needs a beating.:grin2: ...

    Correction, someone needs a beating.:grin2:

    Muriatic acid
  16. Replies
    10
    Views
    879

    Hot gas bypass requires the compressor to...

    Hot gas bypass requires the compressor to constantly compress, with a digital scroll it does not pump when unloaded.
  17. Replies
    14
    Views
    443

    I meant number not address 20.

    I meant number not address 20.
  18. Replies
    14
    Views
    443

    Everything I have looked at and tried comes back...

    Everything I have looked at and tried comes back with the same conclusion that any DX9100 programmable module constant over address 20 can not be added.
  19. What type of reheat, HW or electric? I wouldnt...

    What type of reheat, HW or electric? I wouldnt fail to cool if you have HW reheat.
  20. Model number of the thermostat will help. If...

    Model number of the thermostat will help.
    If you have a fan and or electric heat it would be controlled by PE switches using the normally open contacts and the thermostat would be reverse acting,...
  21. Thread: penn 266

    by hvac69
    Replies
    4
    Views
    212

    Manual...

    Manual
    Page 11 is the default settings. You will need to set each one manually back to default.
  22. Replies
    34
    Views
    1,206

    Great job. Grammy award winner for sure.:cheers:

    Great job. Grammy award winner for sure.:cheers:
  23. Thread: 50 ton voyager

    by hvac69
    Replies
    10
    Views
    445

    Its probably an Altivar 66 drive but I cant find...

    Its probably an Altivar 66 drive but I cant find any literature for TCD600A only 600B which is newer. You can find the drive manual with google
  24. Replies
    3
    Views
    244

    I have not seen that board so I can not comment...

    I have not seen that board so I can not comment on how it will operate. We have a replacement job that the BMS is tstat type control to RTUs and customer does not want to upgrade so when I asked York...
  25. Replies
    3
    Views
    244

    Unplug it. Is it VAV or CV?

    Unplug it. Is it VAV or CV?