Search:

Type: Posts; User: shaka

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Thread: Bryant txv

    by shaka
    Replies
    174
    Views
    10,514

    mr Bill How are you converting it to piston?...

    mr Bill

    How are you converting it to piston?
    do you have a fitting to connect to male thread on the coil?
  2. Thanks Ryan.

    Thanks Ryan.
  3. LENNOX Dealers. Can you tell me if this is an approved match?

    Condenser...
    M# 14ACX-060-230-11

    Evap coil on furnace

    M#CX34-49C-6F-1


    Evap coil is leaking and I need to replace but need to make sure it's an approved match
    Thank you
  4. Replies
    17
    Views
    1,225

    Bez if you have the extra wires like I ask that...

    Bez
    if you have the extra wires like I ask that means your motor is after market.
    I you changed it and installed the same horse power, that motor will mess up.
    Like timjimbob said the oem will...
  5. Replies
    15
    Views
    953

    Is that mean according to watt to speed ratio...

    Is that mean according to watt to speed ratio your fan is actually running at 1150 at high speed?
  6. Replies
    17
    Views
    1,225

    Do you remember if the motor had the extra wires...

    Do you remember if the motor had the extra wires to change rotation?
  7. Replies
    1
    Views
    605

    Do you have pictures You can send to my email...

    Do you have pictures

    You can send to my email on my profile thanks
    I'm interested
  8. Wow 2.5 amps and cools my garage Do you have...

    Wow 2.5 amps and cools my garage
    Do you have model number.
    How much was it
  9. Yes I do feel hvac contractor should be the one...

    Yes
    I do feel hvac contractor should be the one installing the water heater.
    we can handle the the install and the equipment in case it goes down.

    I guess if the plumber install it, he would...
  10. If the water heater was indoor and it's winter,...

    If the water heater was indoor and it's winter, that might get the house too cold.

    I guess you could run just the auxiliary heat in the winter.
  11. So the new unit uses 134a or 410? How old is...

    So the new unit uses 134a or 410?
    How old is your water heater?
    Do you like it?
  12. Heat pump water heater, are we going to work on water heater now?

    Do they call a plumber? I don't think so

    I was just looking at a heat pump water heater
    Any time now we will be working on the water heater too.

    I was thinking of installing one for my...
  13. Thread: No superheat

    by shaka
    Replies
    31
    Views
    1,830

    What's your pressures.? SH,SC I don't see how...

    What's your pressures.? SH,SC
    I don't see how you have a restriction with no superheat.

    We need more info
  14. Thread: Can't find leak

    by shaka
    Replies
    26
    Views
    1,896

    Too bad you can't pressurize the condenser then ...

    Too bad you can't pressurize the condenser then
    Throw it in a swimming pool :grin2:
  15. You don't need to remove the mineral oil. I...

    You don't need to remove the mineral oil.

    I have a walk in cooler with approx 50/50 of MO and Poly
    Been running for over 5 years
  16. Why do feel you have to flush when you convert to...

    Why do feel you have to flush when you convert to 410?
  17. Yup they got into your pocket. I have never...

    Yup they got into your pocket.

    I have never used any RX11
    Not even on burn out.
  18. Replies
    7
    Views
    1,235

    I think I have 3 diff one But I don't use any of...

    I think I have 3 diff one
    But I don't use any of them. Lol
  19. Replies
    17
    Views
    1,142

    Ohh forgot to tell you if the resistance value...

    Ohh forgot to tell you if the resistance value way off the specs
    Compressor is bad, you need to replace it.

    Ignore my last post where I tell you to calculate the back emf..
    That's not...
  20. Replies
    17
    Views
    1,142

    Also get model number of the compressor, Check...

    Also get model number of the compressor,
    Check the original specs on compressor
    Compare winding resistance,
    May have weak winding causing potential relay not to drop out right away. ( cabbboomm)
    ...
  21. Replies
    17
    Views
    1,142

    What's the voltage across run cap.? Run usually...

    What's the voltage across run cap.?
    Run usually goes out by high voltage issues,( cheap cap)
    Start cap usually goes out due to short cycling,
    So check make sure it's not short cycling.
    Check...
  22. Replies
    22
    Views
    1,365

    I'm a super 1) first rule .... The super is...

    I'm a super

    1) first rule .... The super is always right
    2)second rule...... If super is wrong,,, refer to rule one.... LOL


    SUPER AGREES WITH YOUR SUPER. ("SUPER" sounds weird)

    1)get...
  23. Makinhole Sight glass should never be use on...

    Makinhole

    Sight glass should never be use on residential unit.

    You can't base your system charge by a sight glass.
    It will be lying to you.

    The residential unit does not have a receiver,...
  24. I've converted a lot of true box with expansion...

    I've converted a lot of true box with expansion valve.
  25. Replies
    4
    Views
    352

    It's a pulsator relay the black wire is connected...

    It's a pulsator relay the black wire is connected to
    If you follow the brown one it connects magnetic flux imulator that will turn the fan at clockwise
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event