Search:

Type: Posts; User: Kelly T

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    12
    Views
    1,675

    We use the Samsung galaxy tabs as well they are...

    We use the Samsung galaxy tabs as well they are great, take pictures email my self so I dont' forget to do my orders when I get home. have manuals and whatever i need at hand all the time:cheers:
  2. Replies
    26
    Views
    2,617

    I dont' mean to be a misfit but I am a HILTI fan...

    I dont' mean to be a misfit but I am a HILTI fan myself.
  3. Replies
    59
    Views
    3,525

    I second phases motion he is right on

    I second phases motion he is right on
  4. I have used one for years , never had a problem...

    I have used one for years , never had a problem with them, but mainly use them for true boxs and manitiwocs as others have mentioned.

    3 pinch off tools to change a headmaster? why didnt' I think...
  5. Replies
    18
    Views
    1,687

    Got a call late one evening on my way home, a...

    Got a call late one evening on my way home, a tech had been out all day to replace a 3 phase compressor and couldn't get it to run,(i thought he probably has it wired backwards okay i will go out and...
  6. Replies
    53
    Views
    4,680

    I would have to say: JUNK

    I would have to say:

    JUNK
  7. Replies
    5
    Views
    837

    That's about the gist of it

    That's about the gist of it
  8. Replies
    10
    Views
    1,050

    I have never heard of drilling a hole in a true...

    I have never heard of drilling a hole in a true accumalator either. AS far as the small can of 134a 12 oz's is too much if the unit holds 8 ozs each 6 ft hose should hold 1 oz each so you would only...
  9. that is beyond the saying: Welcome to the...

    that is beyond the saying: Welcome to the wonderful world of refrigeration.
    Was some one there to pick you up when you first saw it? :grin2:
  10. Replies
    32
    Views
    3,224

    If the evap is missing nickel, I say hack it and...

    If the evap is missing nickel, I say hack it and get a new one. 14 years is a good run for an ice machine.
  11. Replies
    19
    Views
    1,180

    The ECM do run backwards on occasion, this always...

    The ECM do run backwards on occasion, this always drives me nuts and is a pain when power goes out late at night and comes back on and I get a 2 am call that the temp is going up. I have not found a...
  12. Replies
    11
    Views
    1,208

    Sounds like your bin switch, it will harvest 3...

    Sounds like your bin switch, it will harvest 3 times and when the board has to take itself out of harvest 3 times in a row the unit shuts down, then you have to reset the power or turn the power...
  13. Replies
    11
    Views
    12,496

    Pay me now or pay me later is what it boils down...

    Pay me now or pay me later is what it boils down to. As the others have asked are you staying in your house for awhile? if yes then you are better off replacing the whole system.
    Are you selling...
  14. Replies
    15
    Views
    1,288

    I've done this twice and it never works out for...

    I've done this twice and it never works out for you, companies do it because it works in their favor, I never got screwed but they don't want to pay maint. costs and complain bout using too much gas,...
  15. Replies
    13
    Views
    1,503

    definitely check the t'stat setting, it is also...

    definitely check the t'stat setting, it is also possible that the personell are leaving the door open during their work hours if the gaskets are not bad, t'stat setting and door open or bad door...
  16. agreed, will have to change drier, change or...

    agreed, will have to change drier, change or clear cap tube.
  17. Replies
    12
    Views
    726

    My vote goes to your tech no. 2 as well, i've had...

    My vote goes to your tech no. 2 as well, i've had this happen on occasion i've even gone as far as pulling the coil and charging it with nitrogen and immersing in water and found numerous tiny holes,...
  18. Replies
    35
    Views
    3,749

    I didnt' see where you checked or changed the...

    I didnt' see where you checked or changed the start relay, I would do that if it doesn't help then I would megg the compresor.
  19. Thread: Retro fitting

    by Kelly T
    Replies
    38
    Views
    2,533

    Ummm yeah could be real bad but dont' have enough...

    Ummm yeah could be real bad but dont' have enough info on what you are referring to, alot more to a retro fit than just changing refrigerant.
  20. Replies
    13
    Views
    1,220

    This has happened to me after watching the gasket...

    This has happened to me after watching the gasket smoke and melt I did some research and found out that the wrong heater was put in, my info at the time stated that the door heater should be 6 ohms...
  21. Thread: charging 404a

    by Kelly T
    Replies
    17
    Views
    6,863

    Thats the best advice, most ice machines are...

    Thats the best advice, most ice machines are considered a critical charge and hard to get right if you dont' charge by weight.
  22. Replies
    7
    Views
    1,115

    Alot of people do that to reduce the heat load in...

    Alot of people do that to reduce the heat load in there area, not sure of the heat rejection on a little undercounter cooler but an undercounter ice machine could have 9,000-12,000 btu's heat...
  23. Replies
    16
    Views
    5,446

    not sure what exact model your working on but the...

    not sure what exact model your working on but the high limits do that to me, they were on older models and the high limit was in the back on the top and the wires would break of due to wear the the...
  24. Replies
    17
    Views
    1,830

    I'm not sure which type of defrotst timer you...

    I'm not sure which type of defrotst timer you have but the compressor should shut off when in defrost and the evap fans should shut off, if it is a paragon timer (old type) 3 is defrost and 4 is...
  25. Replies
    9
    Views
    1,033

    The best way to get out of a bad situation is to...

    The best way to get out of a bad situation is to not get into one in the first place. I would of walk away as well.