  1. Replies
    33
    Views
    8,081

    The person that posted this quit working for...

    The person that posted this quit working for these guys back when you could buy 502.
  2. Well if anyone runs into one of these, with the...

    Well if anyone runs into one of these, with the same issue, just look down through the back where the leveling screws are and adjust accordingly.
  3. Vulcan 7680-AB Combo Griddle/Oven question.

    First of all, I hope that is all of the model number.

    Second, can anyone tell me how they hold up the griddle portion of the unit? I have a set of these that are made as one on a steel frame, and...
  4. Replies
    33
    Views
    8,081

    A little explanation is in order here. Have you...

    A little explanation is in order here. Have you ever heard the stories about the cultured people that own a lot of convenience stores here in the good old USA and they like to beat you down on the...
  5. Replies
    31
    Views
    2,248

    What does the inside of the evaporator coil look...

    What does the inside of the evaporator coil look like? And is the drain trapped as per mfg specs if necessary? Just sayin'
  6. Replies
    33
    Views
    8,081

    "Do It Right"

    "'Heating and Cooling" is the name of the company that hacked this one in. I am 100% serious. Not sure if that is schedule 40 or sdr21 for the electrical service.....
  7. Replies
    9
    Views
    1,595

    I saw that and made sure it was the intake pipe....

    I saw that and made sure it was the intake pipe. I could have taken pictures of the whole install but had to get the unit running.
  8. Replies
    9
    Views
    1,595

    What were they thinking?????

    Trap used literally. If they were smart enough to use the pan overflow switch, you would think they would know how to plumb the drain.
  9. Replies
    0
    Views
    984

    What were they thinking?

    Just wonering, are ClimateMaster units supposed to last forever? Our campus is filled with this kind of idiocy.
  10. Replies
    11
    Views
    3,147

    How would you like to get paid?

    How would you like to get paid?
  11. Replies
    11
    Views
    3,147

    These are the ones I am interested in; can you...

    These are the ones I am interested in; can you figure media mail shipping to 66002



    Thanks, mdharris68
  12. Replies
    0
    Views
    1,300

    A/C & Refrigeration Log Template

    Looking for a A/C & Refrigeration Log Template on pdf. Any help appreciated.
  13. Replies
    5
    Views
    4,150

    Thanks, Mark

    Thanks, Mark
  14. Replies
    5
    Views
    4,150

    Can anyone provide a Install operate manual PDF...

    Can anyone provide a Install operate manual PDF for the baysens019b? Can't seem to find it on the Trane Commercial site. Thanks
  15. Replies
    4
    Views
    526

    There is a product called henry's solarflex that...

    There is a product called henry's solarflex that you can use on metal roofs to seal the seams, and I'd bet it would seal the ducts as well.
    ...
  16. Replies
    13
    Views
    1,201

    do the tags give any indication what it is?

    do the tags give any indication what it is?
  17. Replies
    3
    Views
    701

    I would look at your expansion valves and any...

    I would look at your expansion valves and any liquid/suction filter dryers for restriction to rule that out and then look at the liquid line size to assure there is sufficient size to handle the...
  18. Replies
    8
    Views
    1,119

    Well then I need to double check that, the...

    Well then I need to double check that, the suction line to the 14t was sweating but that doesn't mean it was running, I will go back and verify which unit was running with amp meter. I thought it was...
  19. Replies
    8
    Views
    1,119

    What about staging the smaller compressor of each...

    What about staging the smaller compressor of each circuit on first, basically changing the tonnage on the call for cool. This would put 9 tons to work first instead of 14 and may allow the compressor...
  20. Replies
    11
    Views
    3,292

    Thanks for the reply's. I guess I was hoping...

    Thanks for the reply's. I guess I was hoping something could be done short of completely redoing all of the controls in this building.
  21. Replies
    8
    Views
    1,119

    Thanks Allen, it has the MCM and I set it at 40....

    Thanks Allen, it has the MCM and I set it at 40.

    Another question, I have a 50T unit covering an auditorium that seats 500 people. All is functioning properly except it is oversized bigtime....
  22. Replies
    11
    Views
    3,292

    Thanks for the reply's

    Thanks for the reply's
  23. Replies
    8
    Views
    1,119

    Thanks for the reply, I'll check that out. I also...

    Thanks for the reply, I'll check that out. I also noticed in the config menu that it was set up as a 50 ton unit but I have a 30t air handler and a 40t condenser. Is this config option important at...
  24. Replies
    8
    Views
    1,119

    Trane Intellipack Question

    WFHB3004LF
    J95L72675

    RACC404BK03AD1
    J95L82450

    BAYSENS020B

    So I am trying to figure out if when programming the zone sensor if I am changing the supply air setpoint so that the compressors...
  25. Replies
    11
    Views
    3,292

    Automated Logic Controls

    OK, so a little background will help first. I am familiar with automated building controls to the point where if I can walk in to a terminal, sign in and view what's going on and make changes to...
Results 1 to 25 of 500