  1. Thread: Fieldpiece

    by KirtusJon
    Replies
    133
    Views
    21,141

    I got my Sman3 2 months ago and it works great. I...

    I got my Sman3 2 months ago and it works great. I broke the latch on my hard case. Is it possable to order a new latch to pop in there? Thanks you.
  2. Replies
    7
    Views
    1,912

    I have a customer who rents his space for a pizza...

    I have a customer who rents his space for a pizza joint. I get a call that the roof started leaking and it had to be fixxed. The owner of the building now wants someone there to baby sit me when...
  3. Replies
    15
    Views
    2,889

    The thief must have Obsessive-compulsive...

    The thief must have Obsessive-compulsive disorder.:gah:
  4. Not sure what happened, there was no insulation...

    Not sure what happened, there was no insulation on bulb and bulb strap was not pinching bulb. When I turned on condenser, it took less than a minute for suction line to freeze, bubbles in sight...
  5. They can't seem to get it to work just right

    Got a call from one of my customers, pizza joint, that he was having issues with one of his other stores. It is about 45 miles away. He didn't think I would travel. Long story short, walk-in cooling...
  6. Replies
    17
    Views
    2,174

    That's exactly what it looked like.

    That's exactly what it looked like.
  7. Replies
    17
    Views
    2,174

    Yes, new line set at install. I can only the...

    Yes, new line set at install. I can only the someone else was used since last year, ( I usually only put my gauges on six months to a year on this type of maintenance, clean and quick check...
  8. Replies
    17
    Views
    2,174

    Purple oil in compressor burnout.

    Today I worked on a Nordyne 5ton unit with a Copeland scroll compressor. The compressor was shorted between run and start windings. After recovering the R22, I cut the suction line to find it full of...
  9. Replies
    10
    Views
    2,495

    The information I have is based on news articles...

    The information I have is based on news articles only I could not find the info. on the state website. They expect more answers available on a website early August. It is supposed to be a flat fee...
  10. Replies
    9
    Views
    2,016

    I have found quite a few R404a freezers with 180...

    I have found quite a few R404a freezers with 180 valve from R502 "retrofits" and work, But It will work better and properly in the winter when you get a cold spell with the 210 valve

    .

    Summer...
  11. Replies
    2
    Views
    1,120

    I did not see a # on it. I did not think to take...

    I did not see a # on it. I did not think to take it apart to check for a part# when I was there. Most likely I will have to go back and see if # is inside stat.
  12. Replies
    2
    Views
    1,120

    Looking for Part# on Carrier Humidistat

    It sound a little odd but I have customer that I just installed a Carrier 50HJ-008-V531, with a Humidi-MiZer™ adaptive dehumidification system. My customer wants a humidistat to match one they have...
  13. Replies
    61
    Views
    13,648

    A cracked braze in a closed system makes it into...

    A cracked braze in a closed system makes it into an open system.




    How do you know no air or moisture got into system? The HO did not state if the braze was on suction or liquid line. If the...
  14. Replies
    61
    Views
    13,648

    [QUOTE=Silver96Firebrd;4875302] My questions:...

    [QUOTE=Silver96Firebrd;4875302]

    My questions:

    1) How much oil do you think I have left? Is this going to cause premature compressor failure?
    2) Unless it's inside the unit, I don't think I...
  15. Replies
    15
    Views
    672

    I agree. I had the same thing. contact er looked...

    I agree. I had the same thing. contact er looked good (3 phase) and contact would not pull together properly (end of spring hanging it lopsided.) on 1 side. compressor would single phase and kick out...
  16. Replies
    11
    Views
    660

    Yes, twice at the same place. 2 years ago got new...

    Yes, twice at the same place. 2 years ago got new customer and they had issues with all 7 refrigeration units. One was a coffin meat case in which the pressures were way off and thought TXV was wrong...
  17. Is MO49Plus™(R-437A) R-12 Replacement any good?

    I have been using Hotshot as my replacement R-12 refrigerant. I know all of the replacement refrigerants (R-409 / MP39 / MP66 / Hotshot) contain R-22, R-124, and some contain R-142, all HCFC...
  18. Replies
    8
    Views
    818

    I prefer Hoskizaki, because for me, I have very...

    I prefer Hoskizaki, because for me, I have very few issues other then cleaning. With the the right filter system, they seem to never give me problems. If you ever let one go and get extremely dirty,...
  19. Replies
    7
    Views
    659

    Duct Tape & a Few Screws Will Fix It

    I would like you to check out this fan blade that was Repaired by someone I know, more then I would like to say. Lets just leave it at that. Yes I did fix the situation with the factory original fan...
  20. Replies
    33
    Views
    1,192

    Poll: I agree. Its that way here. I personally...

    I agree. Its that way here. I personally believe some try selling so hard because they are unable to do service work with the people they have hired. I call them install companies, because that...
  21. Replies
    33
    Views
    1,192

    Poll: [QUOTE=bwagner62;2178782] So a guy who works on...

    [QUOTE=bwagner62;2178782]
    So a guy who works on HVAC in a commercial setting and practices his trade on the side is a side jobber and not worthy of the professional esteem that I should render to...
  22. Replies
    2
    Views
    560

    You are conforming my thoughts on this. They tell...

    You are conforming my thoughts on this. They tell me the "factory told them" that it was the same BTU's, but I told store manager they were wrong and they needed to send the units I ordered. They...
  23. Replies
    2
    Views
    560

    Rheem Split System In Question?????

    I was to install two 5 ton single phase unit in doctors office. I needed two unit with at least 58,000 BTU's per unit 13 seer. Well, I wanted cube series R-410a system and found 13 seer had only...
  24. new customer wants me for second opinion

    A family member of mine is the manager for a local pizza joint. They were getting water 1/4in deep in walk-in cooler. They finally got owner to call me instead of the usual hvac contractor. I was...
  25. Replies
    161
    Views
    60,371

    I even had "The Old Bold Man" (father in law)...

    I even had "The Old Bold Man" (father in law) with 30 odd years in the hvacr business try to explain it doing my conversation with the gentleman. It did not work. I'm sure some "Joe" sold him his...