  1. What size drive is your furnace? If you have a...

    What size drive is your furnace? If you have a (3) ton drive with furnace common, paired with (3) ton coil and (2.5) ton condenser. The installer can adjust the speed of the blower to match the...
  2. For dust I would start with looking at the duct...

    For dust I would start with looking at the duct system supply side and see if there are any leaks that can pulling the dust into the the system and then blowing it into the home? If so the duct...
  3. Let me state how I explain to customers to how to...

    Let me state how I explain to customers to how to run there system when paired with clean effects (I also have one for my home). My wife and daughter also have bad allergie problems.

    The air...
  4. With your comparison of ford vs BMW they both...

    With your comparison of ford vs BMW they both offer base, mid range and top of the line model cars just like any Pieace of equipment sold like the Trane you have listed.

    That is a base model...
  5. Replies
    10
    Views
    685

    No gas access to my home its total electic so I...

    No gas access to my home its total electic so I choose to go heat pump and variable speed air handler yeilding 15.75 seer rating.

    Electric bill use to be $200-250 before proper sized was...
  6. Replies
    13
    Views
    754

    Having too much work compaired to not having...

    Having too much work compaired to not having enough is a good problem to have! It sounds likes its time to expand in which hiring more people is the next logical move.

    The treat is to hire...
  7. Replies
    10
    Views
    685

    In my 1784 square foot home built in 1978, I have...

    In my 1784 square foot home built in 1978, I have done some major repairs to get the load down.

    Changed out my old double pane metal windows to double pane vinyl with low e and argon, added more...
  8. In moblie homes regardless if double wide or...

    In moblie homes regardless if double wide or single the ductwork is often a problem by design. The equipment to be installed should be rated for moblie home applacition with high static fan motor to...
  9. Replies
    15
    Views
    773

    Agreed! Payne/carrier, Goodman, Trane and rheem...

    Agreed! Payne/carrier, Goodman, Trane and rheem also are just a phone call away.
  10. Replies
    15
    Views
    556

    Emerson motors in my opion are great products. ...

    Emerson motors in my opion are great products. We switched to them about 2 years ago for repairs over gem tech motors that we used for few years. The reason we switched was the gem techs motors...
  11. Out of all the years I have done hvac work, I can...

    Out of all the years I have done hvac work, I can say that I have never replaced a compressor or any other major part on a ptac unit.

    Why the cost to do so is 1/2 if not more then installing a...
  12. Replies
    8
    Views
    498

    I agree with tigerdunes on this but its your...

    I agree with tigerdunes on this but its your choose. 14.5 vs 16 seer is better but $500 credit might be worth it to you?

    Personal I have never installed a gam5 air handler! Why because the TAM7...
  13. As others have stated it more cost effective in...

    As others have stated it more cost effective in southern climates to install a 80% furance over 90% plus furnace. This is due to mild winters and the ROI in those areas don't support the extra cost...
  14. Replies
    8
    Views
    498

    Here is the set I believe you have. 5918099...

    Here is the set I believe you have.


    5918099

    TEM3A0B30S31+TDR - air handler.

    4TTB6030- a/c unit.

    900 cfm rated at
  15. Replies
    8
    Views
    498

    If you paid for the gam5 air handler which has...

    If you paid for the gam5 air handler which has high eff. Motor compaired to the TEM which is just the plan PSE MOTOR.

    It's not that the TEM is bad air handler but its basic compaired to Gam5...
  16. Thread: Heat Load

    by duckman06
    Replies
    8
    Views
    343

    Glad to hear you figured it out. But if you plan...

    Glad to hear you figured it out. But if you plan to use wrightsoft I would suggest training on it not the other.
  17. Replies
    3
    Views
    227

    Both the model numbers for air handlers are for...

    Both the model numbers for air handlers are for either or. Meaning weather it's Trane or American standard the models are the same. While idk why they would quote you Trane condensers and use...
  18. Thread: Heat Load

    by duckman06
    Replies
    8
    Views
    343

    I am filmier with the heat load software you are...

    I am filmier with the heat load software you are using... I would say I have used many over the years and by far the easiest in my opion to use and learn is wrightsoft moblie manual j.

    It...
  19. Replies
    6
    Views
    564

    That's what I was wondering also. Here mr....

    That's what I was wondering also. Here mr. Homeowner you can choose either a (4) or (5) ton system you choose which one you think you need. Talk about confusing for a homeowner!
  20. Man what a plan by him talk big and bad about his...

    Man what a plan by him talk big and bad about his company at the time would address all issues and promised the world to book a sale. Then turn it over to a install crew to make it work!

    I see...
  21. Good way of explaining the problem that most...

    Good way of explaining the problem that most homeowners run into with some companies not all. Sad but the number of companies that don't understand or care to about duct system sizing along with...
  22. 90% closing ratio? Wow that's the best I have...

    90% closing ratio? Wow that's the best I have every heard of. 1st company went out of business? May explain why he closed 90% of sales?
  23. Agree with both on all but If the orginal poster...

    Agree with both on all but If the orginal poster just had this Trane units installed this year then unless he found some old stock ones or his dealer had them they are going to be single stage not 2...
  24. Agreed!!! This would also be my recommdation. ...

    Agreed!!! This would also be my recommdation. Why pay extra $ to have electrical work done to pull circuit for heat pack when you already have hydronic heat? Hydronic heat is cheaper to operate...
  25. Replies
    28
    Views
    2,033

    Now that's some great advice! Listen to udarrell...

    Now that's some great advice! Listen to udarrell on this one he has provided the specs for the system on how it should not be working and how it should be working.

    Improper setup of equipment is...
Results 1 to 25 of 500