    Those 2 10" hoses are good for about 400 cfm...

    Those 2 10" hoses are good for about 400 cfm each. That's enough for 2 tons of air.
  2. Replies
    27
    Views
    2,972

    This is a modulating furnace. The eac terminals...

    This is a modulating furnace. The eac terminals don't get energized until the fan hits a certain rpm. Mean while the furnace is running on low speed and the humidifier is sitting there doing...
  3. Replies
    7
    Views
    518

    Did you buy the one that says that it will work...

    Did you buy the one that says that it will work on heat pump and 2 stage heating and air?
  4. Replies
    41
    Views
    1,961

    I have been installing the new Gibson's and...

    I have been installing the new Gibson's and Frigidaire equipment. They have changed things and are a nice quiet unit. They come with a 10 yr warranty on parts, and lifetime heat exchanger. Also if...
  5. Replies
    5
    Views
    562

    Why change the stat?

    Why change the stat?
  6. Wonder what the inspector said when they had the...

    Wonder what the inspector said when they had the job inspected? OOOps did I say that? Permits? We don't need no stinkin permits. My job speaks for itself.
  7. Replies
    24
    Views
    2,239

    What ever furnace you put in. Make sure you get...

    What ever furnace you put in. Make sure you get one with a variable speed blower motor. It will compensate for inadiquit duct sizes and will be alot quieter.
  8. Replies
    43
    Views
    3,236

    Why blame the installer? The people that design...

    Why blame the installer? The people that design these buildings don't have the slightest idea where the mechanical systems are going to be ran. The don't even leave room half the time for the...
  9. Replies
    20
    Views
    1,171

    I agree with moving the stat to the second floor....

    I agree with moving the stat to the second floor. I would buy a wireless stat. That way you would be able to put it anywhere you would like. Try to balance the system by closing registers on the...
  10. Replies
    3
    Views
    507

    Sounds like someone didn't wire the stat...

    Sounds like someone didn't wire the stat correctly.
  11. Replies
    32
    Views
    1,780

    The ones in the attic are fun also. You come out...

    The ones in the attic are fun also. You come out of the attic covered in insulation because someone decided to blow more in.
  12. Replies
    13
    Views
    775

    I wouldn't mess with the gas valve too much. ...

    I wouldn't mess with the gas valve too much. Call a service company up so it can be safely repaired.
  13. It dosen't matter if it is horizontal or on the...

    It dosen't matter if it is horizontal or on the bottom. Just make sure both pipes pitch back to the furnace at 1/4" per foot.
  14. Replies
    8
    Views
    1,626

    It sounds like a drainage problem to me also.

    It sounds like a drainage problem to me also.
  15. Replies
    41
    Views
    1,961

    Most contractor don't do the load calcs. They go...

    Most contractor don't do the load calcs. They go by rule of thumb. The furnace doesn't sound like over kill. It will definately save you money.
  16. Replies
    27
    Views
    2,972

    The humidifier is hooked up wrong right now. I...

    The humidifier is hooked up wrong right now. I used to be a RUUD dealer so I familar with this furnace. Call a company that has had training on this furnace. The guys that installed this furnace...