  1. Replies
    13
    Views
    2,273

    If your concerned about a leak best bet it to...

    If your concerned about a leak best bet it to focus on BC controller flare fittings will leak if a torque wrench is not used. If isolation valves were used at BC check schrader cores. Most checks I...
  2. Thread: Furnace fire

    by Malarres
    Replies
    24
    Views
    1,383

    My company had a similar problem 2 days after we...

    My company had a similar problem 2 days after we had a tune up tech with a trainee do yearly tune up, both employee's forgot to check and see if they put gas valve plug back in after checking gas...
  3. Replies
    34
    Views
    13,895

    We are having that problem here in Portland Or....

    We are having that problem here in Portland Or. finding indoor coils leaking on inside of A, just replaced 4 last week alone,
  4. Replies
    18
    Views
    5,100

    I'll be installing the Coleman Mod furnace in my...

    I'll be installing the Coleman Mod furnace in my own house this sept will match up with my Coleman 15 SEER 2 stage HP.
  5. Thread: mismatched

    by Malarres
    Replies
    16
    Views
    1,257

    Tell owner you have to do it right or walk away...

    Tell owner you have to do it right or walk away you will be one doing warranty work.
  6. Replies
    6
    Views
    997

    May want to have contractor put some isolation...

    May want to have contractor put some isolation pads under unit.
  7. Replies
    26
    Views
    2,409

    Makes me think of beer can cold charging rule,...

    Makes me think of beer can cold charging rule, Sure don't miss my first trainer.
  8. Replies
    16
    Views
    1,202

    I'd make sure they don't bring over the used unit...

    I'd make sure they don't bring over the used unit and install it on your house.
  9. Replies
    29
    Views
    1,478

    I pay my HOA well to take care of my yard, house...

    I pay my HOA well to take care of my yard, house was painted by a subcontractor and i have a low voltage license as long as i don't run a new circuit I'm legal to change i now what I'm qualified to...
  10. Replies
    64
    Views
    10,119

    I have to agree R-22 is being phased out in 2020...

    I have to agree R-22 is being phased out in 2020 if prices follow what R-12 reached when it was phased out you will be wishing you put in a 410a system. other guys are right on, please make sure...
  11. Replies
    35
    Views
    2,317

    I forgot one other small thing you may help me...

    I forgot one other small thing you may help me with being slow minded but last I checked you must run unit for a amount of time to get a proper super heat and subcooling maybe where your from thats...
  12. Replies
    35
    Views
    2,317

    Since i was posting in non prof form's im sorry...

    Since i was posting in non prof form's im sorry to infom you yes super heat, Sub cooling, lets keep it going Amp draw on compressor would go a long way to help with info but since we have a very...
  13. Question for you have you been doing your part to...

    Question for you have you been doing your part to help unit by changing air filter? If not you may have a plugged filter causing furnace to have a fault code, still have a tech come out some of the...
  14. Replies
    2
    Views
    439

    Does not sound like a big issue, just have your...

    Does not sound like a big issue, just have your yearly Tune up performed let your HVAC company know before hand so they have some insulation with them. May also plan on replacement in near future.
  15. Replies
    35
    Views
    2,317

    My question to you would be, Has this company...

    My question to you would be, Has this company been working on unit year after year not including yearly maint? have you had any costly repairs over the 15 yr run if unit normally needs Freon added to...
  16. Replies
    54
    Views
    4,605

    Our company has has this problem with 5 Ton HP we...

    Our company has has this problem with 5 Ton HP we install in rural area's, we were losing compressor's used hard start kit's found kick starts to be the stronger of two. After mutable calls got a...
  17. Replies
    5
    Views
    629

    In 2010 new equipment will no longer be using...

    In 2010 new equipment will no longer be using R-22, replacement R-22 will still be produced when R-12 was being fazed out prices went sky high over night, 410A has proven to be a good refrigerant.
  18. Replies
    19
    Views
    4,420

    I have to agree with Berg2666 if you head out to...

    I have to agree with Berg2666 if you head out to A/C unit look ut info plate you will see a line Max fuse Size if Labeled 40 Amp, the breaker is correct.