  1. Replies
    11
    Views
    2,032

    You can use any version of CARE higher than 5.0...

    You can use any version of CARE higher than 5.0
    use the highest version you have...CARE 10.01.02 is the highest release right now.

    This is the problem you are probably facing.
    If the program you...
  2. Replies
    59
    Views
    6,371

    Setting a JACE up to pass the Token to a SAGE :(

    OK,
    this is what I know.
    99% of SAGE installations have the SAGE set as the "sole Master" of a PUP network.
    In these installations, Token passing is disabled and the SAGE has Complete control of...
  3. Replies
    5
    Views
    485

    If you have the ability to recompile and...

    If you have the ability to recompile and redownload the spl program, insert section numbers (SECTION 3. etc) after each line and then the section number attribute will tell you where it is hanging....
  4. A couple of years ago, there was a bad round of...

    A couple of years ago, there was a bad round of XL50s shipped, they all lost memory after a power failure.

    Does your XL50 lose all its memory (or just the its lon commissioning)?

    At a minimum,...
  5. Replies
    11
    Views
    2,032

    The XL1000 can be configured to log on to a smtp...

    The XL1000 can be configured to log on to a smtp server and send emails.

    There are a few Email to SMS services available. I'm sure one of these will work
  6. Replies
    11
    Views
    2,032

    That smiley face was supposed tyo be a ; )

    That smiley face was supposed tyo be a ; )
  7. Replies
    11
    Views
    2,032

    when you translate the controller with CARE, the...

    when you translate the controller with CARE, the EDE file is automatically created in the care/projects/jobname folder. it will have a name like controllername_EDE.csv.
    the file will have semicolons...
  8. Replies
    17
    Views
    1,609

    i will assume that you are trying to download a...

    i will assume that you are trying to download a global schedule into a xl5000 (c bus) controller.
    this means you are trying to download a global schedule into a xl5000 time program
    the download...
  9. APOGEE terminal box controller communications protocol?

    I have a number of SIEMENS APOGEE terminal box controllers that have a + and - terminals for communications.
    Does anyone know what protocol this unit uses for communications?
    is it Profibus?
    they...
  10. In the same window where the LNS Controlled...

    In the same window where the LNS Controlled checkbox is, there is a checkbox under it that says "enable CARE Controller flow parameters for Honeywell VAV2 devices.
    It is supposed to be checked
  11. Replies
    4
    Views
    612

    Make sure that you have followed my procedure...

    Make sure that you have followed my procedure carefully.
    If you lost ity. let me know and i will leave a new copy on your desk

    ** NOTE: If you have downloaded a Zone Manager and do not have valid...
  12. Replies
    17
    Views
    5,908

    Everyone should be using RapidBalance 4.0

    Everyone should be using RapidBalance 4.0
  13. Too Funny

    Too Funny
  14. Get a PCC-10 card from echelon

    Get a PCC-10 card from echelon
  15. E-Vision uses the real mode drivers (originally...

    E-Vision uses the real mode drivers (originally loaded in the config.sys file)
    these drivers were accessed directly by the E-Vision program
    the last physical interface that had real mode support...
  16. Reloading 40 controllers sounds like a lot of...

    Reloading 40 controllers sounds like a lot of work.

    I doubt the problem was corruption due to C-Bus comm problems.
    The fact that all 40 controllers had this problem makes it clear that SymmetrE...
  17. E-Vision uses the real mode drivers (originally...

    E-Vision uses the real mode drivers (originally loaded in the config.sys file)
    these drivers were accessed directly by the E-Vision program
    the last physical interface that had real mode support...
  18. Replies
    4
    Views
    1,149

    The babelBuster does not need LonMaker to bind...

    The babelBuster does not need LonMaker to bind any points.
    We do use Lonmaker when we want to update the bablebuster to a newer version (APB/NXE download)

    There is a config property that has an...
  19. there is a PB-376 which details how to resize the...

    there is a PB-376 which details how to resize the alarm and event summarys pages.
    I think that it was on one of the install CDs for R300.
    If you cant find it post back and i will dig for it deeper....
  20. How can you do a site audit without physically...

    How can you do a site audit without physically visiting each panel?
    I think that you need to do this just to see what modules are installed

    Anyway, you dont state whether or not these controllers...
  21. There was a utility that allowed the user to...

    There was a utility that allowed the user to connect directly to the B Port of a controller and interact with inputs and outputs.
    This utility was different from XL-Online, XI584 emulator, XBS, Live...
  22. Replies
    20
    Views
    4,755

    OK, Let me restate. If you want to use only...

    OK, Let me restate.
    If you want to use only Honeywell supplied software then it's the LNS database that requires a "Re-Synchronization" when changes are made. EBI doesnt have the ability to manage a...
  23. Replies
    20
    Views
    4,755

    Honeywell's answer to upgrading the system to EBI...

    Honeywell's answer to upgrading the system to EBI is to use LNS. The XL10VAV controllers could be re-integrated into an LNS controlled lon network

    Right now you probably have zone managers...
  24. Are there any good choices for Maintenance Management Software?

    Does anyone know of any good options for Maintenance Management Software?
    Preferably one that supports using an OPC interface.
    We are trying to find some options for Honeywell SymmetrE systems
    ...
  25. Replies
    6
    Views
    1,743

    I think that the network number does not have...

    I think that the network number does not have that much influence on this topic.
    The network number seems to have some effect on the actual communications, but the logical datapoint definitions only...