  1. Replies
    17
    Views
    1,323

    Thanks for the feedback, guys. I am leaning...

    Thanks for the feedback, guys. I am leaning towards the York for now to use with my existing wifi t-stat. Operating like NC described would work very well for me. And if I ever wanted to step up...
  2. Replies
    17
    Views
    1,323

    The Trane logic with the generic 2 stage T-stat...

    The Trane logic with the generic 2 stage T-stat sounds like just what I am looking for and my 3M stat does control 2 stages of heat and cool. I am in MD so winter temps can vary widely and there are...
  3. Replies
    17
    Views
    1,323

    Those communicating systems seem like they would...

    Those communicating systems seem like they would produce the most accurate response to need. But to do that they have to use the proprietary thermostats. Maybe they also have an algorhythmic mode...
  4. Replies
    17
    Views
    1,323

    What is the "cph parameter". I don't see that...

    What is the "cph parameter". I don't see that term in the literature.
  5. Replies
    1
    Views
    622

    Interesting... I am not a pro but that seems like...

    Interesting... I am not a pro but that seems like a smallish furnace for such a big structure in the great white north. A friend just had a new Trane system installed yesterday here in Maryland,...
  6. Replies
    17
    Views
    1,323

    My stat has a time adjust feature but i find it...

    My stat has a time adjust feature but i find it easier just to set the actual time I want the thing to kick on than to have a time when I want the temp to be X. It just isn't that critical.

    But...
  7. Replies
    17
    Views
    1,323

    Thanks for the input amp.... I am hoping that...

    Thanks for the input amp....

    I am hoping that some of these modulating furnaces would work w/o a proprietary thermostat. I have a Wifi enabled 3M thermostat that does 1 or 2 stages and I would...
  8. Replies
    17
    Views
    1,323

    How does a modulating furnace modulate?

    I am looking to upgrade my HVAC and going through the usual research between single stage, 2-stage, and modulating furnaces. I have read some of the threads here on this already.

    I have also...
  9. Replies
    4
    Views
    557

    The answer is that the coil does indeed come with...

    The answer is that the coil does indeed come with a couple of pre made sheet metal adapters installed to reduce the bottom opening of the coil case to fit a narrower width furnace. To use on my...
  10. Replies
    4
    Views
    557

    No, the T in this position of the model number is...

    No, the T in this position of the model number is "Transition". The tin "T" comes later in the model number. I found the carrier spec sheet and it has this to say:

    "Transition coil models CNPVT...
  11. Replies
    4
    Views
    557

    Carrier "Transition" N-coils?

    What, if any, difference is there between similar capacity (say 3 ton) and same dimension (depth x height x width) Carrier CNRVP and CNRVT (the T being "transition") cased N-coils? Can they be used...
  12. Replies
    8
    Views
    5,528

    Well, it's been a couple years since I cleaned...

    Well, it's been a couple years since I cleaned everything but no way this is a dirt issue. We're talking about a serious mechanical clunk, the kind that gives me a start when I am upstairs in bed. ...
  13. Replies
    8
    Views
    5,528

    Thanks for the input, Kevin. I'll check out the...

    Thanks for the input, Kevin. I'll check out the things you suggested... at least the ones I can, when I get a chance. If nothing pans out I guess I'll just let it RTF and then have a BBQ and...
  14. Replies
    8
    Views
    5,528

    refrigerator compressor clunk on shutoff

    My 14 year old GE fridge is still working fine... except that half of the time when the compressor cycles off it makes a horrific clunk/bang kind of sound. The other half of the time it shuts off...
  15. Replies
    15
    Views
    917

    That won't work in a townhome here the land of...

    That won't work in a townhome here the land of home owners associations. And to be honest I wouldn't be happy if any of my neighbors tacked a roaring tankless box on the front of their houses. ...
  16. Replies
    5
    Views
    423

    It's for a retrofit hot water recirc system like...

    It's for a retrofit hot water recirc system like those sold by Watts and Grundfos. Problem is the setpoint (~95) on the supplied fixed temp mixing/sensing valve is way too low. 105-110 would be...
  17. Replies
    5
    Views
    423

    valve experts, will this work?

    I am working on a project to deliver water to a point on a hot supply line and when it reaches a set temp to stop or greatly reduce the flow. I haven't found a specific valve that will do this but...
  18. Replies
    12
    Views
    1,961

    electronic diagnostics

    My parents' Whirlpool elec has similar diagnostics. But in my experience with theirs whatever flashing pattern it produced basically meant that the controller was broke and you were screwed. :-/ ...
  19. Replies
    12
    Views
    1,961

    Well, you got me thinking about recirc pumps...

    Well, you got me thinking about recirc pumps again so I just went to the Depot and got one of those Watts units that mounts on the WH hot water outlet. It was more reasonable than the other mostly...
  20. Replies
    12
    Views
    1,961

    Maybe some. But it has always behaved this way,...

    Maybe some. But it has always behaved this way, even when relatively new. At first I even suspected that I had one of those bad dip tubes that would disintegrate and allow cold water coming in to...
  21. Replies
    12
    Views
    1,961

    You're the first data point I could find on the...

    You're the first data point I could find on the Hydrosense. In general I have found that electronics either fail right away or are good to go for a very long time. So hopefully the Honeywell box...
  22. Replies
    12
    Views
    1,961

    +/- 18 degrees would be great! My variation is...

    +/- 18 degrees would be great! My variation is more like 25-30 degrees. I need to get more feedback on the new digital controllers like the Sears/Honeywell Hydrosense. Their advertising says...
  23. Replies
    12
    Views
    1,961

    Yes, I have looked into the recirc pumps. I...

    Yes, I have looked into the recirc pumps. I almost did one 5 years ago but they cost almost as much as a water heater. I suppose the timer operation would flow enough to activate the WH but the...
  24. Replies
    12
    Views
    1,961

    Thanks for the feedback on the thermostat. I was...

    Thanks for the feedback on the thermostat. I was thinking that it had to be an abnormally wide control range. It has always been that way. The spring feels stiff when I turn the 'stat which makes...
  25. Replies
    12
    Views
    1,961

    Gas WH thermostat control band

    I have been looking into tankless WHs lately partly because the way my current NG water heater thermostat behaves. The temp at the nearest tap just after a heatup cycle is about 132. But the burner...