EPR = Evaporator Pressure Regulator Since...
EPR = Evaporator Pressure Regulator
Since there are more than one evaporators for only one condenser, an EPR is used to make sure each evaporator has the proper pressure. Used a lot in... -
06-30-2009, 11:14 AM
Thread: What size is this a/c unit?
by zrox- Replies
- 2
- Views
- 263
The model number 030 usually (Not always. Some...
The model number 030 usually (Not always. Some companies don't follow the standard) means 30,000 btu's which is 2.5 tons.
-
06-30-2009, 11:07 AM
Thread: Please help me help my tech
by zrox- Replies
- 61
- Views
- 2,563
Maybe it was a "if all else fails, add...
Maybe it was a "if all else fails, add refrigerant" moment :rolleyes:
The tech probably could'nt find the problem and decided to "wing" it! -
06-30-2009, 09:56 AM
Thread: Please help me help my tech
by zrox- Replies
- 61
- Views
- 2,563
Loss of refrigerant and the tech found no leak...
Loss of refrigerant and the tech found no leak :confused:
Maybe the tech has a leak :rolleyes: -
06-30-2009, 09:42 AM
Thread: Ooops Wrong Address!!!
by zrox- Replies
- 20
- Views
- 1,126
lol :D
lol :D
-
06-29-2009, 10:02 AM
Thread: Can moisture removal be calculated?
by zrox- Replies
- 11
- Views
- 427
Use a psychrometric chart :D
Use a psychrometric chart :D
-
06-23-2009, 10:46 AM
Thread: Cold air return goes outside
by zrox- Replies
- 14
- Views
- 744
Is that a federal code throughout the United...
Is that a federal code throughout the United States? I thought that it was a local building code. Why have a fresh air intake if your house doesn't need it?
-
06-22-2009, 11:14 AM
Thread: 1-2 year residential air filter replacement?
by zrox- Replies
- 13
- Views
- 722
Nicely said! :rolleyes: Change the filters...
Nicely said! :rolleyes:
Change the filters every month or so. It takes less than a minute. -
06-22-2009, 10:51 AM
Thread: Flared fittings on refrigerant lines
by zrox- Replies
- 16
- Views
- 1,216
Especially when you're in a hurry :D Yeah, but...
Especially when you're in a hurry :D
Yeah, but flare nuts works great. I use them for installing TXV's and driers if they are being replaced. Just make sure they're good and tight.
Hope... -
06-22-2009, 10:43 AM
Thread: Is Carrier worth more than Payne
by zrox- Replies
- 9
- Views
- 1,741
A comparison between between Carrier and Payne? ...
A comparison between between Carrier and Payne? As far as I know, the only difference is the name tag. Carrier's do tend to usually have more "sophisticated gadgets." But, if that's not a big deal...
-
06-22-2009, 10:29 AM
- Replies
- 8
- Views
- 603
If getting a new unit, I recommend getting a...
If getting a new unit, I recommend getting a heatpump (if money is right) and use the gas furnace you already have for auxillary heat. Again, check around and as said before: "If it sounds too good...
-
06-22-2009, 10:22 AM
Thread: Cold air return goes outside
by zrox- Replies
- 14
- Views
- 744
I know that a lot of northern parts of the United...
I know that a lot of northern parts of the United States use fresh air intakes, but I don't think that it is a law. Could be wrong, though! I know that in Florida it is not required in residential.
-
06-22-2009, 10:17 AM
Thread: Does position of TXV bulb matter?
by zrox- Replies
- 45
- Views
- 5,899
Is this really a new install? :eek: Tape on the...
Is this really a new install? :eek: Tape on the TXV? Ahh... Anyways, definitely check superheat to make sure the TXV is working properly. Might want to give that company back a call.
-
06-18-2009, 11:16 AM
Thread: fan off delay time
by zrox- Replies
- 14
- Views
- 1,786
if you have a time delay in your unit, then the...
if you have a time delay in your unit, then the fan will run for a set number of minutes after the compressor turns off. this is usually done to get more out of the unit. how long the blower will run...
-
06-18-2009, 11:10 AM
- Replies
- 5
- Views
- 383
3/4 lbs of refrigerant in 1.5 months??? Sounds...
3/4 lbs of refrigerant in 1.5 months??? Sounds like a leak to me. Did the tech made sure that the reed valves on the compressor wasn't leaking due to old age?
-
06-18-2009, 11:04 AM
Thread: 13 or 14 Seer
by zrox- Replies
- 4
- Views
- 343
Generally speaking, I would go with the 14 SEER. ...
Generally speaking, I would go with the 14 SEER. I don't know anything about your house so telling you which furnace to get is useless. More info would be nice :rolleyes:
-
06-18-2009, 11:01 AM
Thread: Recovery Unit???
by zrox- Replies
- 7
- Views
- 2,970
Recovery Unit???
I was thinking about purchasing a recovery unit, but was a little stuck. Anyone used the Diablo Reftec Oilless High-Speed Refrigerant Recovery Unit? I used the Appion G5 Twin before and was...
-
06-18-2009, 10:55 AM
Thread: Name a country starting with the letter U
by zrox- Replies
- 5
- Views
- 1,387
ROFL
ROFL
-
06-18-2009, 10:46 AM
Thread: Mini-split for my house
by zrox- Replies
- 9
- Views
- 602
mchild's right, you can't just size an a/c by...
mchild's right, you can't just size an a/c by area. There's other factors involved such as walls, windows, doors, etc. My advise, call someone reputable and let that person size a unit properly for...