Search: Search took 0.10 seconds.
-
Yesterday, 08:07 AM
- Replies
- 145
- Views
- 11,098
I was just at the Lennox factory and every joint...
I was just at the Lennox factory and every joint gets brazed with nitro.
-
05-21-2013, 02:58 PM
Thread: Everything in America is illegal
by chuckcrj- Replies
- 5
- Views
- 159
Wow.
Wow.
-
05-20-2013, 11:30 PM
Thread: oil furnace electrodes
by chuckcrj- Replies
- 7
- Views
- 156
A few things can cause that; 1. bad nozzle...
A few things can cause that;
1. bad nozzle (yes even a new one) or dirt in the nozzle from servicing
2. low nozzle pressure ("lots of fuel" doesn't tell me much)
3. air shutter adjusted too far... -
05-20-2013, 09:47 PM
- Replies
- 42
- Views
- 988
A daily drift of 2 degrees would make me unhappy....
A daily drift of 2 degrees would make me unhappy.
The only fieldpiece temperature instruments I use regularly do not have thermocouples. I don't really trust t-couples. -
05-20-2013, 08:01 PM
Thread: Digital gauge manifold
by chuckcrj- Replies
- 70
- Views
- 1,344
You can get a very good set for $290 with...
You can get a very good set for $290 with manifold, no need to spend $600+
http://shop.rdholder.com/Digi-Cool-AK900-Digital-Refrigerant-Manifold-Digi-Cool-AK900.htm -
05-19-2013, 10:43 PM
Thread: FP SC56 issue
by chuckcrj- Replies
- 9
- Views
- 190
How old is it? Give them a call, I'm sure they...
How old is it?
Give them a call, I'm sure they stand behind it. -
05-19-2013, 10:37 PM
Thread: FP SC56 issue
by chuckcrj- Replies
- 9
- Views
- 190
Mine has been fine. Did it just read zero...
Mine has been fine.
Did it just read zero amps, or did you get an error message? -
05-19-2013, 07:32 PM
Thread: Trane heat exchangers
by chuckcrj- Replies
- 66
- Views
- 5,931
When a crack gets to the point of leaking, it is...
When a crack gets to the point of leaking, it is hazardous to have air blowing into the HX. This affects the flame and can cause dangerous rollout and elevated CO levels. Wouldn't it be better to...
-
05-19-2013, 01:52 PM
Thread: Burnham ES2 boiler CO issue cont'd
by chuckcrj- Replies
- 15
- Views
- 228
The problem is, a boiler can go from 10 ppm of CO...
The problem is, a boiler can go from 10 ppm of CO to 10,000 ppm in seconds if certain outside conditions change. If the flue gases start spilling, the CO produced can spike.
-
05-19-2013, 01:48 PM
Thread: Burnham ES2 boiler CO issue cont'd
by chuckcrj- Replies
- 15
- Views
- 228
The plain truth is, a technician properly trained...
The plain truth is, a technician properly trained in combustion analysis and CO would be able to pinpoint the problem on the first visit. This training is optional and relatively few technicians...
-
05-18-2013, 10:22 PM
Thread: digi-cool ak900 vs testo 570
by chuckcrj- Replies
- 6
- Views
- 326
If you scroll down through the tool forum...
If you scroll down through the tool forum threads, you will soon be able to see the opinions of the guys on this site :)
I would take AK900, no question. The 570 has lots of cool options and... -
05-16-2013, 11:21 PM
Thread: Mitsubishi heat pump question
by chuckcrj- Replies
- 10
- Views
- 293
What flash code are you getting?
What flash code are you getting?
-
05-16-2013, 07:10 PM
Thread: Tool backpacks
by chuckcrj- Replies
- 15
- Views
- 506
Not anymore. Zippers are not covered and to use...
Not anymore. Zippers are not covered and to use the zero downtime warranty costs extra.
-
05-15-2013, 11:01 AM
Thread: Combustion Analyzers
by chuckcrj- Replies
- 26
- Views
- 560
Boards are repairable too if you know the right...
Boards are repairable too if you know the right guy.
-
05-15-2013, 08:52 AM
Thread: Combustion Analyzers
by chuckcrj- Replies
- 26
- Views
- 560
I would like it better if I hadn't gotten used to...
I would like it better if I hadn't gotten used to the TSI first.:o
-
05-11-2013, 06:42 PM
Thread: Combustion Analyzers
by chuckcrj- Replies
- 26
- Views
- 560
Testo 320 or Bacharach Insight plus are very good...
Testo 320 or Bacharach Insight plus are very good choices.
-
05-11-2013, 06:37 PM
Thread: Nordyne to close Missouri plants
by chuckcrj- Replies
- 11
- Views
- 469
All Lennox furnaces, a/c and heat pumps except...
All Lennox furnaces, a/c and heat pumps except the Merit series are made in Marshalltown, Iowa.
Allied Air has manufacturing in SC I believe for the Armstrong and Airease brands. -
05-11-2013, 10:40 AM
Thread: Rocool 600
by chuckcrj- Replies
- 12
- Views
- 294
You know you want one
You know you want one
-
05-10-2013, 08:33 PM
Thread: UEI AK900SC
by chuckcrj- Replies
- 13
- Views
- 427
Good thing for Doug and Brenda
Good thing for Doug and Brenda
-
05-10-2013, 08:32 PM
Thread: Rocool 600
by chuckcrj- Replies
- 12
- Views
- 294
The manifold block on them looks exactly like the...
The manifold block on them looks exactly like the Testo 550.
382101 -
05-07-2013, 11:10 AM
- Replies
- 25
- Views
- 942
Here's a great blog post on the subject. ...
Here's a great blog post on the subject. http://ncidavid.blogspot.com/2013/05/is-system-effect-impacting-your.html?m=1
-
05-06-2013, 10:59 PM
Thread: A good entry level psychrometer?
by chuckcrj- Replies
- 4
- Views
- 265
Yes, I really like mine, price is right too.
Yes, I really like mine, price is right too.
-
05-06-2013, 10:53 PM
- Replies
- 25
- Views
- 942
Two or three scenarios can cause it to not come...
Two or three scenarios can cause it to not come out equal. The first and most likely is duct leakage. The next is the fact that anything between the two static measuring points that is dirty,...
-
05-04-2013, 11:33 PM
Thread: Atheism to Defeat Religion By 2038
by chuckcrj- Replies
- 17
- Views
- 421
LOL you got me there, twilly does it in a funny...
LOL you got me there, twilly does it in a funny Jeff Foxworthy style
-
05-04-2013, 11:18 PM
Thread: Atheism to Defeat Religion By 2038
by chuckcrj- Replies
- 17
- Views
- 421
And BTW, your third person talk is a tad creepy...
And BTW, your third person talk is a tad creepy :.02: just saying :)