  1. Replies
    4
    Views
    1,259

    Wait!!! I see it!!! you should really fix that...

    Wait!!! I see it!!! you should really fix that a-flex on the suction line!!!
  2. Yup, practice. A big diagram is really no...

    Yup, practice. A big diagram is really no different than a smaller one. It just has more components. If you follow it one wire at a time, it should still make sense to you. They are overwhelming...
  3. Replies
    15
    Views
    1,224

    one that is designed for r-22 but doesn't have...

    one that is designed for r-22 but doesn't have any in it (not precharged)
  4. Replies
    22
    Views
    1,070

    How do you know the refrigerant levels and...

    How do you know the refrigerant levels and subcooling are fine? What about superheat? Does the coil LOOK clean or did you clean it? How do you know airflow is fine?
  5. Replies
    16
    Views
    1,011

    c'mon, skip... no diy...

    c'mon, skip... no diy...
  6. :eek2:

    :eek2:
  7. Replies
    42
    Views
    5,148

    This is quite vague. If you are asking who owns...

    This is quite vague. If you are asking who owns the "Hussmann" name, I believe its Ingersall Rand.
  8. Replies
    40
    Views
    3,297

    I seem to remember a question very similar to...

    I seem to remember a question very similar to that on the EPA Cert. test....
  9. Replies
    14
    Views
    1,935

    When you disassemble the check valve, there is a...

    When you disassemble the check valve, there is a raised ring on the inside of the plastic body (the part you take off with the 3 screws) that sits against the rubber. I have seen this part get chewed...
  10. Replies
    3
    Views
    409

    Why the sad face?:grin2:

    Why the sad face?:grin2:
  11. Thread: norlake

    by nightranger121
    Replies
    22
    Views
    1,282

    I was working on one last week that was a cap...

    I was working on one last week that was a cap tube system. The only walk-in I have ever seen that ran on a cap tube. Weird.
  12. We can't discuss pricing on here. It still...

    We can't discuss pricing on here.

    It still seems to me that you want to make this more difficult than it needs to be. If you can't remote them outside, is there a cooler place in the building you...
  13. That's a good idea, too

    That's a good idea, too
  14. So, just to understand, you can put a hose onto...

    So, just to understand, you can put a hose onto it and pressurize the braze joint without piercing the copper tubing, right? I can't wait to pick up some of these and try them.
  15. Replies
    19
    Views
    1,548

    Yeah, I was picturing a totally different...

    Yeah, I was picturing a totally different scenario. I don't do resi.
  16. If you have space to put a ventilation system on...

    If you have space to put a ventilation system on the roof or outside wall, why can't you just pipe out the condensing units and put them out there? It will be much cheaper too.
  17. Replies
    5
    Views
    1,257

    Definitely a violation!

    Definitely a violation!
  18. Replies
    14
    Views
    2,029

    Had a similar situation once... walk-in freezer...

    Had a similar situation once... walk-in freezer down, found system at 0psig. Not an ounce in it. Pressurized and leak-checked to no avail. Charged it with 404a and haven't had to touch it since. Its...
  19. You know, I see those things all the time at the...

    You know, I see those things all the time at the supply house and never realized you could put them on a charged system. Do they work good? I never thought you could torch a charged system. sounds a...
  20. Replies
    19
    Views
    1,548

    Not sure if I am understanding what you are...

    Not sure if I am understanding what you are trying to do correctly, but would a large trash bag work?
  21. Replies
    6
    Views
    463

    Sounds like in theory it should work. Definitely...

    Sounds like in theory it should work. Definitely need the water reg. valve.
  22. Replies
    8
    Views
    3,324

    That made me laugh.

    That made me laugh.
  23. Looks like mine almost has the same pole!

    Looks like mine almost has the same pole!
  24. Thread: norlake

    by nightranger121
    Replies
    22
    Views
    1,282

    At least the newer ones I have seen are...

    At least the newer ones I have seen are stainless. I think the replacements are coming as stainless now, too.
  25. Replies
    22
    Views
    1,500

    Anyone else having a problem with the 8145-20...

    Anyone else having a problem with the 8145-20 clocks? over the course of the summer we had about 4 of them that stopped keeping time within the first few weeks (if they ever did). We are fighting...