Search:

Type: Posts; User: STEVEusaPA

Page 1 of 12 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    10
    Views
    341

    No return line. But, all flared fittings, pipe...

    No return line. But, all flared fittings, pipe dope, no Teflon tape. If you're coming out of the bottom of the tank, up the ceiling and back down, keep in mind the osv is only providing protection...
  2. Replies
    10
    Views
    341

    This sight doesn't allow posting prices. The 38...

    This sight doesn't allow posting prices.
    The 38 is for 3/8 oil lines and the 50 is for 1/2" oil line. I've never heard of a 25, so I would avoid that model.
    You'll almost always use 3/8" on a...
  3. Replies
    10
    Views
    341

    Oil Safety Valve is put as close to the tank...

    Oil Safety Valve is put as close to the tank (after the filter) as possible. It opens on vacuum. If the oil line were to split down stream of the valve, it wouldn't open and allow the oil tanks to...
  4. Are you a tech or a homeowner? Yes,...

    Are you a tech or a homeowner?

    Yes, absolutely. Do you know how to properly test, using the proper settings on a professional meter, and how to interpret the testing? Leave it to the guy doing...
  5. Replies
    6
    Views
    507

    Do the heat loss. Don't oversize the boiler,...

    Do the heat loss. Don't oversize the boiler, don't oversize for the indirect. If someone tries to install a bigger unit without doing a heat loss, find someone else
  6. Unfortunately, your contractor and your landlord...

    Unfortunately, your contractor and your landlord know nothing about hydronic heat, how to properly diagnose the problem, and ultimately how to fix it. Or your landlord doesn't want to invest any...
  7. Replies
    6
    Views
    339

    I assume Craig meant if the circulator was...

    I assume Craig meant if the circulator was running an no water was in the system.
    Why do you think you need to replace the cartridge? Is something going on? Do you have a water quality issue? ...
  8. Do the usual matinence on your computer-clean up...

    Do the usual matinence on your computer-clean up caches, cookies, etc. Also Update your Adobe. There was an antivirus issue with older versions
  9. Replies
    9
    Views
    515

    A company that rents med/large generators would...

    A company that rents med/large generators would have these. Ask your electrician.
  10. How ya even getting the diesel to flow a that...

    How ya even getting the diesel to flow a that temp?
  11. Replies
    21
    Views
    1,220

    What was the name/brand of the torque wrench?

    What was the name/brand of the torque wrench?
  12. Call Trane, tell them the problem and the name of...

    Call Trane, tell them the problem and the name of the installer. Ask them for the name of a more qualified installer. Have them check the entire system, making sure it's the proper equipment,...
  13. Honeywell customer service is in India.......?

    Honeywell customer service is in India.......?
  14. Replies
    10
    Views
    537

    Whenever I go out of the country, I add an...

    Whenever I go out of the country, I add an international plan to my phone for one month. Gets you gobs of data, discounted phone rates and usually lots of free text. There's also lots of free wifi...
  15. Get the same diameter of smoke/duct pipe. Make...

    Get the same diameter of smoke/duct pipe. Make your cut perfect, then wrap it around the stainless to mark it.
  16. Replies
    13
    Views
    767

    Yeah shut er down. It wouldn't come on if that...

    Yeah shut er down. It wouldn't come on if that zone wasn't connected right?
  17. Replies
    13
    Views
    767

    I would have it removed (the timer). You don't...

    I would have it removed (the timer). You don't need the boiler firing. You could add an outdoor reset module which would prevent the boiler from firing during the off season, but I wouldn't want my...
  18. Replies
    14
    Views
    1,334

    Another thing, log info on every component on...

    Another thing, log info on every component on every system for every customer. This way you can have the parts you need put on the boat before you get there. Obviously, you can't do this for a new...
  19. Thread: Shorts

    by STEVEusaPA
    Replies
    14
    Views
    907

    Those shorts are fine....for now. It about 10 or...

    Those shorts are fine....for now. It about 10 or so years, you're going to start showing 'brain'..:Faint:
  20. C'mon timebuilder, how long have you been...

    C'mon timebuilder, how long have you been watching sports in Philly? We both know if he's any good, he will fail (curse of William Penn) :).
    I know what position he should play....left out.
    He...
  21. If he only has one good tooth he should be taking...

    If he only has one good tooth he should be taking care of it.
  22. Yeah, the circus is back in town. TeBLOW...Maybe...

    Yeah, the circus is back in town. TeBLOW...Maybe he learns how to throw before the season starts. Energize?...lol..and I'm actually Laughing out loud. We've had plenty of 'energizers'...no rings. ...
  23. Replies
    6
    Views
    375

    Get a point & shoot infrared thermometer and...

    Get a point & shoot infrared thermometer and point it at the wall. Same kind of situation at a bagel place near me. Thermostat on partition wall, other side of wall was the ovens. Wall was about...
  24. Replies
    7
    Views
    533

    Tubing diameter/spacing is based on a room by...

    Tubing diameter/spacing is based on a room by room heat load-btu's needed, type of material (slab, sleepers, wetbed, warmboard, aluminum plates), and type of floor covering-r value if pad/carpet, or...
  25. Did you look here?...

    Did you look here?
    http://www.americanvan.com/stor-king-aluminum-drawer.html
  26. Replies
    36
    Views
    1,556

    Read my first post again...

    Read my first post again...
  27. Most good ones come as a kit with a printer. In...

    Most good ones come as a kit with a printer. In my opinion, you should at least leave a printout there, and take one with you (or save it on your analyzer). I usually staple it to the card I leave...
  28. Replies
    36
    Views
    1,556

    Once again, you don't know the what the pressure...

    Once again, you don't know the what the pressure is on the expansion tank unless it's isolated, or removed from the system. Just putting a pressure gauge on the tank is not accurate.
  29. Replies
    36
    Views
    1,556

    I don't think your boiler pressure is 60 PSI. ...

    I don't think your boiler pressure is 60 PSI. Can you post a pic of it? Also you can't check the pressure of your tank attached to your system under pressure. It needs to be isolated, the system...
  30. The indirect should be maintaining a min temp of...

    The indirect should be maintaining a min temp of 140 to eliminate the growth of legionella. But it should be mixed down much lower to prevent scalding in the domestic water lines, unless every...
  31. You appear to have a...

    You appear to have a grounding/bonding/electrolysis issue that needs the intervention of a very competent electrician
  32. Replies
    11
    Views
    519

    Your boiler is not 72psi. It would've blown up by...

    Your boiler is not 72psi. It would've blown up by now. Your reading the gauge wrong. You're looking at Feet of H20. On the other side of the blue line is PSI, which is probably slightly over 30...
  33. Maybe the circulator?

    Maybe the circulator?
  34. Replies
    0
    Views
    238

    Angie's List?..LMAO

    http://philadelphia.cbslocal.com/2015/03/24/web-site-angies-list-sued-for-fraud-in-federal-court-in-philadelphia/

    ...
  35. You got a leak, any tech would dump refrigerant...

    You got a leak, any tech would dump refrigerant in (twice) without finding a leak is not a person I would call back and pay. Leaks don't get better with time.
    If he wants to come out, find the leak...
  36. Replies
    4
    Views
    594

    I used a rotary one (haven't had it out in a few...

    I used a rotary one (haven't had it out in a few years) for checking the pitch on a bunch of steam mains in a basement that was divided up with lots of crap on the floor. This one could be tripod...
  37. Improper grounding/short circuit? How's the...

    Improper grounding/short circuit? How's the draft? Burner flange gasket good/tight? When you're running in heat mode, how hot does it get around the control. I had one with poor over fire draft...
  38. Replies
    8
    Views
    545

    What happens after he uses it for back up? ...

    What happens after he uses it for back up? Complete flush and hopefully no legionella?
    In a pinch I would just use some space heaters.
  39. Replies
    15
    Views
    1,084

    ALOT of Japanese people read...

    ALOT of Japanese people read Japanese..........:grin2:
    Seriously though, either get the name of the equipment and download an English Version, or stop by a Japanese restaurant, get some take out,...
  40. Replies
    46
    Views
    3,282

    Tell her 'You're welcome for me finding this...

    Tell her 'You're welcome for me finding this before the roofer killed you'. Then give her a price to fix everything properly. Seems like almost everyone doesn't have enough money to do the job...
  41. Replies
    17
    Views
    1,589

    I guess it's like leasing a car or paying a...

    I guess it's like leasing a car or paying a mortgage. If you cant write a check for it, you pay in installments....and pay and pay.
  42. Replies
    12
    Views
    757

    While youre addressing the thermostat issue to...

    While youre addressing the thermostat issue to keep you going, you said electric is cheap. I would SAFELY set up some electric heaters...STRONGLY recommend you have an electrician give it a look...
  43. Replies
    9
    Views
    1,511

    Do you have a humidifier? What make/model? If...

    Do you have a humidifier? What make/model? If you have one, I would start there, if that isn't the problem, then you got lots of investigating to do
  44. Replies
    9
    Views
    1,684

    If only anyone could just buy one at a big box...

    If only anyone could just buy one at a big box store........hmmmmm.
    Actually I know a few plumbers who should remove the "& Heating" lettering from their trucks, thinking just because they can...
  45. You have to dig a little deeper with the bids. ...

    You have to dig a little deeper with the bids. That boiler can be direct vented, under proper conditions. If those conditions are met, why would you want a power venter? Yes more maintenance, more...
  46. Replies
    17
    Views
    2,737

    Give it a whirl...what do you intend to mostly...

    Give it a whirl...what do you intend to mostly use if for? For $89 less the coupon they perennially run, have some fun with it. If it finds one cracked heat exchanger it paid for itself
    I use some...
  47. Did you ask them? Direct Vent or thru a chimney?...

    Did you ask them? Direct Vent or thru a chimney? Chimney needs to be lined?
    Either the one's not recommending the power vent, missed something that the one suggesting the power vent saw, or the one...
  48. Replies
    5
    Views
    485

    Wouldn't surprise me, when you get a one and only...

    Wouldn't surprise me, when you get a one and only post from someone, if it isn't an attempt at a free plug for their own site
  49. Replies
    5
    Views
    485

    With a name like that they have to be...

    With a name like that they have to be bad.....lol...Just kidding I don't know anything about them.
    But, good reviews can be invented. Bad reviews can not have all the important information, just...
  50. Replies
    5
    Views
    518

    Might be a vacuum leak at the filter or strainer...

    Might be a vacuum leak at the filter or strainer (sucking in air). Or if there are any compression fittings that were bumped. Not all air leaks result in fuel leaks