Search:

Type: Posts; User: Core_d

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. 598311

    598311
  2. Replies
    7
    Views
    158

    Ive read you can go bigger... By how much i...

    Ive read you can go bigger... By how much i forget up to 250 somthing like that.
  3. They make a universal you can sucton cup on the...

    They make a universal you can sucton cup on the side of the fridge and run the bulb like the old one.
  4. Replies
    78
    Views
    1,840

    Starting out in the trade you need hand tools and...

    Starting out in the trade you need hand tools and what not. Ive took the stance if it needs borrowed it needs baught. I try everyday and run into issues from every direction. The day dont hold...
  5. Replies
    78
    Views
    1,840

    Sorry, no excuse for bad practices. Charging a...

    Sorry, no excuse for bad practices. Charging a unit to 150 with nitro and waiting a certain time then pulling a vacuum while buttoning up and putting aways is not good practice. I knew that. I...
  6. Replies
    78
    Views
    1,840

    To add on that.. With a txv if its too cold...

    To add on that.. With a txv if its too cold outside you overcharge if its too hot inside you overcharge. I dont pay much attention to the subcooling out side specs if i cant wait for it to pull...
  7. Replies
    78
    Views
    1,840

    I forget the memo but from memory 404 & 410A it...

    I forget the memo but from memory 404 & 410A it is normal to see a lazy river of flow. Ie not a full column. This is more likely in high indoor temps or low outdoor ambient.
  8. Replies
    3
    Views
    161

    Look for pinched or lose wires in the tam that is...

    Look for pinched or lose wires in the tam that is issues i have seen, iide dring a board with me though maybe call train and see what they say. The blower should come on
  9. Replies
    3
    Views
    161

    You could try variable speed testing and put it...

    You could try variable speed testing and put it in 100% see how it does that basically the same as charging mode
  10. Replies
    78
    Views
    1,840

    Havent bought one myself yet but this thread has...

    Havent bought one myself yet but this thread has definitely moved it up on my list. Used one of my coworkers sman 3s today with the micron gauge pulled an evap coil and linset down to about 430...
  11. Replies
    78
    Views
    1,840

    Good for you! Ive seen a sight glass on a split...

    Good for you! Ive seen a sight glass on a split system, that was the lennox dist.
  12. Replies
    78
    Views
    1,840

    So i had an opportunity today to use a micron...

    So i had an opportunity today to use a micron guage. my pump wouldnt hardly get below 640 or so in a reasonable time on a multi head mini. Gonna change the oil and pull the core out tomorrow on an...
  13. Thread: Death Trap

    by Core_d
    Replies
    47
    Views
    5,525

    P stands for propane duh

    P stands for propane duh
  14. Replies
    78
    Views
    1,840

    I realize the advice im getting here is sound and...

    I realize the advice im getting here is sound and i will get there eventually.
  15. Replies
    14
    Views
    1,491

    That will get chuckles for years to come:P

    That will get chuckles for years to come:P
  16. Replies
    78
    Views
    1,840

    I do need to get a micron gauge..... Just got an...

    I do need to get a micron gauge..... Just got an ecm tester though....
  17. Replies
    78
    Views
    1,840

    Evacuation process?

    How many microns is 30" mercery?
  18. 10 pac? Thats good for one job.

    10 pac? Thats good for one job.
  19. Thread: Nest issues.

    by Core_d
    Replies
    2
    Views
    220

    Had 2 do it this last few weeks

    Had 2 do it this last few weeks
  20. Thread: Nest issues.

    by Core_d
    Replies
    2
    Views
    220

    Nest issues.

    Just a heads up if you get a indoor fan cutting out look at the nest it cuts out so quick my motor cant see it.
  21. Replies
    30
    Views
    967

    Your flooding negative SH... Also known as SC :)

    Your flooding negative SH... Also known as SC :)
  22. I agree it sucks.......do they have 5/16 locking...

    I agree it sucks.......do they have 5/16 locking caps for minis? On unit would require 8 fing caps [emoji37]
  23. Replies
    78
    Views
    1,840

    Ok, not saying my methods are perfect. I put in...

    Ok, not saying my methods are perfect. I put in a drier. Ive not had issues... Always looking for ways to improve but for now im happy and confident in my process. Some systems a svrt is not gonna...
  24. Replies
    78
    Views
    1,840

    You dont use nitro at all?

    You dont use nitro at all?
  25. Replies
    78
    Views
    1,840

    No, hand tools and test equipment is my...

    No, hand tools and test equipment is my responsibility. I have no problem with that he provides classes, van, refrigerant. Recovery device, nitro, he would give me a torch and pump if i needed one....
  26. Take steel wool and plug up any remotely possible...

    Take steel wool and plug up any remotely possible access.
  27. Ive heard the mothball trick. Had a customer put...

    Ive heard the mothball trick. Had a customer put a mesh bag full of mothballs in the electrical compartment. Mouse chewed up the bag and built a nest on top of it:) scared the hell out of me as he...
  28. Replies
    78
    Views
    1,840

    Ive tested my pump at over 750 microns i pull...

    Ive tested my pump at over 750 microns i pull down till it sounds the same with valves closed. Just cant afford a micron guage right now and its not high on my list as I have plenty of buttoning up...
  29. Replies
    78
    Views
    1,840

    Cant you mess up the oil pulling to deep of a...

    Cant you mess up the oil pulling to deep of a vacuum?
  30. Replies
    9
    Views
    715

    Not familiar with pistons? I agree 3'f is too...

    Not familiar with pistons? I agree 3'f is too high across the drier. Its probably has a drier in the condenser too.
  31. Thread: New here

    by Core_d
    Replies
    21
    Views
    636

    Those condensers are steel they never leak and jp...

    Those condensers are steel they never leak and jp is right. Step away from the fridge they con really be a nightmare for u and you tenant.
  32. Replies
    38
    Views
    887

    Yea thats correct, first time out the fan was...

    Yea thats correct, first time out the fan was not spinning, unit frozen up. Second time out replaced board other unit frozen up and still a water issue with that unit. Did a leak search yesterday...
  33. Thread: Capacitors

    by Core_d
    Replies
    4
    Views
    344

    Capacitors

    The same motor can have a different sized cap per the load its intended for. I think its best to just do what your told. If its not within specs recommend replacement.

    Not that i go around...
  34. Replies
    19
    Views
    2,077

    Lol

    Lol
  35. Replies
    38
    Views
    887

    Well the issue was a plugged drain.... Too bad...

    Well the issue was a plugged drain.... Too bad it took out there board and they need an evaporator on there other system.
  36. Replies
    38
    Views
    887

    Ive got a lennox with sever blow off that im...

    Ive got a lennox with sever blow off that im looking at today. Ill try to get a video of it. I suspect the coil is plugged although it looks spotless .
  37. Replies
    38
    Views
    887

    Thats what i said :P

    Thats what i said :P
  38. Replies
    38
    Views
    887

    Its tricky if you can set the cfm slow the fan...

    Its tricky if you can set the cfm slow the fan down. Take off any blower delay and RUUUUN
  39. Replies
    38
    Views
    887

    Well he only installed air handlers with slab...

    Well he only installed air handlers with slab coils wrong ;) the ones with electronic /auxiliary drain pan
  40. Replies
    41
    Views
    2,582

    Yep

    Yep
  41. Replies
    18
    Views
    763

    Is it just here or does nobody tighten there...

    Is it just here or does nobody tighten there acorns? Should get 1 1/4 turn
  42. Replies
    38
    Views
    887

    Ive seen on bryants too. Last guy a wooked for...

    Ive seen on bryants too. Last guy a wooked for actually made a plexy glass door for the coil so he could watch it.

    Can a plugged coil cause this?
  43. Replies
    6
    Views
    351

    Quick question.... How much is 12,000 fifty centz...

    Quick question.... How much is 12,000 fifty centz anywayz?
  44. Replies
    6
    Views
    351

    Add 50centz per btu

    Add 50centz per btu
  45. Replies
    6
    Views
    351

    600$

    600$
  46. Replies
    9
    Views
    491

    Wat is that?

    Wat is that?
  47. Replies
    18
    Views
    763

    Pressures are high on the indoor coil, for...

    Pressures are high on the indoor coil, for heatpumps that is true on the whole lineset. How often you have a leaker that did fine end of last year?
  48. Replies
    18
    Views
    763

    Winter is leak time heat pump or not.

    Winter is leak time heat pump or not.
  49. Replies
    18
    Views
    553

    I think not needing a g it pretty common and mot...

    I think not needing a g it pretty common and mot all that new, if the stat does call g too its no big deal
  50. Replies
    18
    Views
    553

    Yea depends on the stat and wheter you use the...

    Yea depends on the stat and wheter you use the ylo terminal or not so it still does get told its cooling.
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4