Search:

Type: Posts; User: digo

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Thread: Microtech 100

    by digo
    Replies
    2
    Views
    347

    RTFM. You should not be changing the leaving...

    RTFM. You should not be changing the leaving water temperature (that is likely a read-only value). Maybe what you're after is the setpoint?
    google CENT1V32.pdf
  2. Replies
    4
    Views
    348

    User-Agent switcher for Chrome:...

    User-Agent switcher for Chrome:
    https://chrome.google.com/webstore/detail/user-agent-switcher/ffhkkpnppgnfaobgihpdblnhmmbodake?hl=en

    Firefox:...
  3. Thread: Niagara Spy

    by digo
    Replies
    2
    Views
    259

    When you right click a host and choose spy, you...

    When you right click a host and choose spy, you can see the title reads "Remote Spy." This is true for local (running on your laptop) or remote stations (like on a JACE or remote Supervisor)
    ...
  4. Replies
    9
    Views
    395

    Good lord, thanks for the memories. I'm so glad I...

    Good lord, thanks for the memories. I'm so glad I haven't touched CARE/SymmetrE in years.
  5. Replies
    9
    Views
    395

    call the contractor who put it in, no one here is...

    call the contractor who put it in, no one here is going to help you
  6. hahahaha I've been called a controls puke and a...

    hahahaha I've been called a controls puke and a keyboard jockey.
    I'm laughing all the way to the bank.
    :putergreet:
  7. Replies
    2
    Views
    209

    Yes. 1931 ≠ 1911

    Yes. 1931 ≠ 1911
  8. Do you have any support from Nagios? I'm...

    Do you have any support from Nagios?

    I'm assuming this is the plugin you're using:
    https://github.com/AndreySV/check_modbus

    Anything useful from running this?

    /check_modbus --help.
    ...
  9. Replies
    3
    Views
    486

    are you sure? maybe try fetching the license from...

    are you sure? maybe try fetching the license from the server. The message tells you you have the require nre core dist available to be installed, but it can't be done without a license upgrade. ...
  10. Thread: Using HTTPS on AX

    by digo
    Replies
    6
    Views
    582

    Read up the prerequisites section in...

    Read up the prerequisites section in docs\docSSL.pdf

    During install, the old crypto.jar is removed from the modules folder. The new module is called platCrypto.jar
  11. Thread: Using HTTPS on AX

    by digo
    Replies
    6
    Views
    582

    which version of AX is running on this customer's...

    which version of AX is running on this customer's site?
  12. Replies
    5
    Views
    599

    The JCE unlimited strength policy files are only...

    The JCE unlimited strength policy files are only required if you're running AX 3.8.

    There are separate policy files for Java 7 and Java 8.
  13. Replies
    4
    Views
    562

    See these threads:...

    See these threads:
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/8811
    https://community.niagara-central.com/ord?portal:/discussion/DiscussionThread/15803
  14. Replies
    8
    Views
    682

    Kele has this transducer... takes a...

    Kele has this transducer... takes a voltage/current input, outputs the resistance. You'd need to order the one with a custom range to match the curve of a 20K ohm sensor....
  15. Replies
    8
    Views
    682

    The 20K ohm sensor is a resistive device. It...

    The 20K ohm sensor is a resistive device. It doesn't send out a signal. Instead, a controller sources a voltage through it to figure out its resistance by measuring the voltage drop. A programmable...
  16. Do you have Rover SP12?

    Do you have Rover SP12?
  17. Replies
    7
    Views
    671

    I have 3 WEB-700 in a large data center, dual Lon...

    I have 3 WEB-700 in a large data center, dual Lon cards in each, MODBUS/TCP and SNMP on another, and MODBUS/RS-485 on another. No issues whatsoever.
  18. Thread: Remote FX Server

    by digo
    Replies
    7
    Views
    704

    I believe tunneling is a feature available on a...

    I believe tunneling is a feature available on a supervisor, I've never tunneled through a JACE. Fox tunneling that is.
  19. I'd ask for clarification, perhaps they could...

    I'd ask for clarification, perhaps they could provide you with an IP rating instead
    http://www.cctvco.com/NEMA-IP-ingress-protection-explained.html
  20. Replies
    2
    Views
    277

    bingo. I know it sucks, but I bet you won't make...

    bingo.
    I know it sucks, but I bet you won't make that mistake again.
  21. Replies
    14
    Views
    749

    So you're pulling in 15 stations into an existing...

    So you're pulling in 15 stations into an existing supervisor, that was not provided and licensed by you. Is that correct? Are they going into fault?
  22. Replies
    14
    Views
    749

    A single JACE

    A single JACE
  23. Replies
    14
    Views
    749

    No device limit

    No device limit
    <feature name="niagaraDriver" expiration="never" virtual="true" schedule.limit="none" point.limit="none" history.limit="none" device.limit="none"/>

    Small building limited to 3...
  24. Replies
    28
    Views
    5,916

    while Mr. bigguy158 stayed in Controls (Green Bay...

    while Mr. bigguy158 stayed in Controls (Green Bay area?) working with big blue, and occasionally going for bike rides? btw, how's the solar setup at the cabin going?
    Indeed google is scary.
  25. Thread: EC BOS ?

    by digo
    Replies
    4
    Views
    294

    Or the sticker under the cover

    Or the sticker under the cover
  26. Thread: EC BOS ?

    by digo
    Replies
    4
    Views
    294

    License Manager, next to hostid

    License Manager, next to hostid
  27. Did you look in the AxCommunity.jar? In the...

    Did you look in the AxCommunity.jar?

    In the math palette they have an AbsTimeOffset object that can be used to subtract a time offset in seconds

    3.6 and newer will automatically convert the...
  28. Replies
    9
    Views
    647

    To clarify, if designed one way or the other it...

    To clarify, if designed one way or the other it shouldn't matter. I'm not advocating running the wheel opposite from the direction the manufacturer intended.
  29. Replies
    9
    Views
    647

    I'd be willing to bet it doesn't matter....

    I'd be willing to bet it doesn't matter. Regardless of the direction the wheel spins, you still achieve the heat exchange/recovery between EA/OA and RA/SA.
  30. See this thread:...

    See this thread:
    http://hvac-talk.com/vbb/showthread.php?1244511-Trane-BCI-C-(BACnet)-UC400-Questions

    Tracer BACnet Setup Tool 3.0:
    http://software.trane.com/GCC/BST.Setup.3.0.74.exe
  31. Yeah, I'd set them to null and not proxy those...

    Yeah, I'd set them to null and not proxy those points.
    TUNCOS is used to ramp the unoccupied setpoint toward the occupied setpoint based on a specific ramp rate. I know with the CVAHU controller...
  32. Use nviTodEvent for scheduled occupancy. I...

    Use nviTodEvent for scheduled occupancy. I believe the nviOccCmd is meant to share occupancy sensors accross multiple VAVs.
    When the wall module is configured with a bypass button, pressing the...
  33. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    4,432

    When I get back to the office on Tuesday I'll...

    When I get back to the office on Tuesday I'll check on the uptime of my WRT54GL and let you know the last time it rebooted. Monthly reboots aren't caused by crappy hardware, they're caused by buggy...
  34. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    4,432

    I guess I haven't bought on of those in a...

    I guess I haven't bought on of those in a while... I agree with you on Belkin. Anything found on the same isle as monster cables at best buy can't be good.
  35. Thread: BBMD vs VPN

    by digo
    Replies
    43
    Views
    4,432

    Linksys was aquired by Cisco long ago. Most would...

    Linksys was aquired by Cisco long ago. Most would agree they're a reputable manufacturer, albeit sometimes the priciest in the enterprise arena. The WRT54GL model was one the best routers in the...
  36. Replies
    4
    Views
    400

    This is old but it explains the sequence in...

    This is old but it explains the sequence in detail: http://support.microsoft.com/kb/124036
  37. Replies
    2
    Views
    408

    Exchange 2013?...

    Exchange 2013?
    http://blog.kloud.com.au/2013/11/22/exchange-2013-dns-settings-cause-transport-services-to-crash/
  38. Replies
    299
    Views
    34,885

    Any protocol at layer 2 (data link layer) is...

    Any protocol at layer 2 (data link layer) is inherently non-routable. ARCnet, ATM, Controller Area Network (CAN), Ethernet, Fiber Distributed Data Interface (FDDI), Frame Relay, LocalTalk,...
  39. Replies
    32
    Views
    5,240

    What up Kirk! So you're saying you don't miss...

    What up Kirk! So you're saying you don't miss working with spudders? [emoji1]
    Hope all is well with you man.
  40. Replies
    32
    Views
    5,240

    wow, if their panel looks like this, imagine the...

    wow, if their panel looks like this, imagine the wire sheet on those spyders... definitely wall of shame contender.
  41. Replies
    1
    Views
    269

    Use the file transfer client to copy it from the...

    Use the file transfer client to copy it from the modules folder in the JACE to your 3.7.106 modules
  42. Thread: AX Histories

    by digo
    Replies
    2
    Views
    421

    Start indicates the time it began collecting,...

    Start indicates the time it began collecting, like after a reboot
  43. Replies
    2
    Views
    576

    Strykers are configurable (ASC), Spyders are...

    Strykers are configurable (ASC), Spyders are fully programmable. Either way, you have to proxy your points and create your own graphic template before duplicating them. Both are licensed products. ...
  44. Assuming you dragged...

    Assuming you dragged WeatherService/WeatherReport/Current to a Px page, change the "tempFont" property to 0.0pt, then use a separate bound label to display your own temperature value.
  45. Yes, it's called fox tunneling.

    Yes, it's called fox tunneling.
  46. Thread: Niagara AX?

    by digo
    Replies
    2
    Views
    437

    Paste special gives you the option to retain...

    Paste special gives you the option to retain existing links
  47. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    518

    Never

    Never
  48. Thread: 24vac signal amp

    by digo
    Replies
    5
    Views
    518

    Take a picture of it... any chance it's...

    Take a picture of it... any chance it's mislabeled?
    I can see an IDF room having of those CATV signal amplifiers in it. Maybe the 24V transformer is powering the signal amplifier?
  49. Take a look at the property sheet for the...

    Take a look at the property sheet for the LonNetwork, under Monitor you can disable the "Alarm on Failure" property which is a baja:Boolean slot. If you're running 3.6 or newer you shouldn't need a...
  50. Replies
    5
    Views
    838

    ":p" translates to a smiley on the forums :p

    ":p" translates to a smiley on the forums
    :p
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards