08-22-2012, 08:19 PM
- Replies
- 22
- Views
- 1,611
use what size cap. it calls for on Motor. sorry...
use what size cap. it calls for on Motor. sorry didnt explain that better
-
08-22-2012, 08:18 PM
- Replies
- 22
- Views
- 1,611
i have replaced lots of motors on Condensors with...
i have replaced lots of motors on Condensors with dual cap. U hook black and yellow to contactos and brn to fan side of cap and the brn/white to common side of cap. it will be fine. Make sure if the...
-
08-22-2012, 08:12 PM
Thread: Orange-ish Pink AEV?
by lsu4life- Replies
- 16
- Views
- 897
I would talk with some of the guys at the supply...
I would talk with some of the guys at the supply houses on this one, just to get it right the first time, Or call the manufacture just to be safe. thats what i do if I aint 100% sure.
-
08-22-2012, 08:10 PM
- Replies
- 21
- Views
- 1,768
Yes I agree on the opening of doors of cooler....
Yes I agree on the opening of doors of cooler. Most times we got calls was everytime the delivery truck came and the door is left open never shut and sucks in hot air from kitchen then it freezes up...
-
08-22-2012, 08:01 PM
Thread: Orange-ish Pink AEV?
by lsu4life- Replies
- 16
- Views
- 897
I have seen where other companies came and...
I have seen where other companies came and changed things to use different Refrigerant.
-
08-22-2012, 07:55 PM
- Replies
- 24
- Views
- 1,590
This is the Ask Our Pro's forum. In order to post...
This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
-
08-22-2012, 07:52 PM
Thread: Orange-ish Pink AEV?
by lsu4life- Replies
- 16
- Views
- 897
404
404
-
08-22-2012, 07:50 PM
Thread: Oldest one I have ever worked on
by lsu4life- Replies
- 20
- Views
- 1,936
89. I have worked on and replaced ones from the...
89. I have worked on and replaced ones from the 70's down here in Louisiana
-
08-22-2012, 07:48 PM
Thread: Service Technicians where are u?
by lsu4life- Replies
- 52
- Views
- 5,686
It is hard to find good People to stay around...
It is hard to find good People to stay around even down South Louisiana. Most places dont pay good and no benefits to offer so most guys leave after a few yrs of training. If u find a good tech that...
-
08-22-2012, 07:38 PM
Thread: Low charge causing frozen evap coil?
by lsu4life- Replies
- 93
- Views
- 8,022
Low pressures will cause frozen coil just as a...
Low pressures will cause frozen coil just as a stopped up filter or bad fan motor on inside unit or low air flow maybe from a to small of return for size of unit.
-
08-22-2012, 07:33 PM
Thread: Need some feedback
by lsu4life- Replies
- 18
- Views
- 974
I agree with you man. I have had other companies...
I agree with you man. I have had other companies come behind my guys and bad mouth us for not hooking them up say these things to the customer and heck these people dont know if this correct or not....
-
08-22-2012, 07:30 PM
Thread: york microchannel
by lsu4life- Replies
- 20
- Views
- 1,232
Ok this is what I want to know you installed this...
Ok this is what I want to know you installed this new 410A Condensor, what about the coil inside? What age is the that coil? Did you add the TXV or did it have a Flow rater? Just asking to understand...
-
08-22-2012, 07:25 PM
Thread: Need some feedback
by lsu4life- Replies
- 18
- Views
- 974
Well yes I do know this Jtrammel. I have been...
Well yes I do know this Jtrammel. I have been told that if it is not hooked the motor will burn up quicker and then told it wont, ETC:
-
08-22-2012, 07:23 PM
Thread: BTU's per square feet
by lsu4life- Replies
- 48
- Views
- 5,844
Most will figure 500 sq ft per ton, but also U...
Most will figure 500 sq ft per ton, but also U will need to consider lots of factors. Cause I have been many homes with lots of windows and very high ceilings and that figure want work. Also some...
-
08-22-2012, 07:10 PM
Thread: Need some feedback
by lsu4life- Replies
- 18
- Views
- 974
Need some feedback
I want to know if anyone knows the facts on hooking up the ground wire on Condensor fan motor. Does it have to be hooked or not? I have heard way to many assumptions. I need facts. Thanks:whistle: