Search:

Type: Posts; User: dan sw fl

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. LOCATION... LOCATION ... LOCATION... I GUESS...

    LOCATION... LOCATION ... LOCATION...

    I GUESS TX.
  2. Replies
    44
    Views
    1,959

    http://yourairexperts.com/services/air-quality

    http://yourairexperts.com/services/air-quality
  3. http://www.williamson-thermoflo.com/en/williamson/...

    http://www.williamson-thermoflo.com/en/williamson/pd-90-gas-furnace-upflow/

    54,000 input 49,000 output
    along with 3 ton Max
  4. Natural Gas price .. $1.13 to $1.30 ...

    Natural Gas price .. $1.13 to $1.30
    _____________Nov 2013 to _ Jan, 2014

    http://www.eia.gov/dnav/ng/hist/n3010ct3m.htm
  5. VERY, VERY WEIRD .. No discussion of the...

    VERY, VERY WEIRD ..

    No discussion of the furnace in a HUGELY predominant Heating locale.
    Heating Degree Days are 8 to 12 times the Cooling Degree Days

    Current Heating cost is probably 20 X...
  6. How's the air flow? Static pressure on 1....

    How's the air flow?
    Static pressure on
    1. return
    2.supply

    What are all the condenser set-up readings?

    IF YOU DON'T KNOW, You don't have a clue on what the work quality was or lack thereof....
  7. Replies
    4
    Views
    225

    I suspect heat loss would be < 40,000 BTU/HR at...

    I suspect heat loss would be < 40,000 BTU/HR at 10'F.

    https://www.energycodes.gov/adoption/states/idaho
  8. Replies
    4
    Views
    225

    Very little cooling required ( Cooling Degree...

    Very little cooling required ( Cooling Degree Days < 700 ) + Very Dry ?
    DESIGN 92'F AT 62'F Wet Bulb

    HEATING IS VERY SIGNIFICANT ,,, ~ 10'F
    Elevation might be 4,500 feet
    ...
  9. Replies
    4
    Views
    225

    Does anyone in central Idaho have Significant...

    Does anyone in central Idaho have Significant experience Zoning residential systems?
  10. Replies
    24
    Views
    529

    You only need utility bills Each of the last 24...

    You only need utility bills Each of the last 24 months AND LOCATION
    As a general ALTERNATE CHECK
    on the other calculation(s).
  11. Apparently, you FROZE Them out of the place. No...

    Apparently, you FROZE Them out of the place.
    No one was able to stay on the couch.

    What's the SEE R rating?
  12. Replies
    4
    Views
    241

    IMPORTANT .! is at the bottom of the 2nd page. ...

    IMPORTANT .!
    is at the bottom of the 2nd page.

    Warranty void if ....

    http://www.alpinehomeair.com/related/Aprilaire%20600%20Series%20Installation%20Instructions%2004.10.pdf
  13. Replies
    4
    Views
    241

    ... Watching or Asking them when installing = ...

    ... Watching or Asking them when installing =
    $70 for 1st question + $ 120 / hr for answers
    _________________

    When you have your car serviced, do you "HELP" Them also?
    ...
  14. http://gandhiappliances.com/shop/220v-window-air-c...

    http://gandhiappliances.com/shop/220v-window-air-conditioners/multistar-ms12hcmer-12000-btu-heat-cool-window-air-conditioner-w-remote-control-220-volts/
  15. What's the issue? In less than 16 words? ...

    What's the issue?
    In less than 16 words?


    http://www.eastwestintl.com/showprod.asp?subid=61&catid=33
  16. Replies
    24
    Views
    529

    ASHRAE 1% ... 88 hours per year .Dry Bulb 88'F...

    ASHRAE 1% ... 88 hours per year
    .Dry Bulb 88'F
    Wet Bulb 73'F
    Relative Humidity 49% ( rather low)

    0.4% .. 35 hours per year > 90'F
  17. Replies
    9
    Views
    258

    Your contractor SAID He performed a Manual J...

    Your contractor SAID
    He performed a Manual J calculation.

    The furnace WILL cycle A LOT (running < 1/3 of the time) for ALL equipment,
    except for modulating furnace or heat pumps,
    at say 30'F...
  18. Replies
    17
    Views
    569

    80% single stage is Not a good recommendation...

    80% single stage is Not a good recommendation where HDD > 5,000.
    + Natural Gas rates for a decade or three (or even a year or three) can not be estimated with certainty.
    $80 to $100 per year...
  19. Replies
    17
    Views
    569

    Natural Gas ... in the range of $0.80 / therm ...

    Natural Gas ... in the range of $0.80 / therm

    http://www.eia.gov/dnav/ng/hist/n3010il3m.htm
  20. Replies
    17
    Views
    569

    I understand that Even With ~15% increase in...

    I understand that Even With ~15% increase in Chicago electric rates that
    they will be VERY LOW

    Integrys $0.055 / kw-hr + $22.36 /Month fixed fee [ =~ $0.077 at 1,000 kw-hr usage OR = $0.087...
  21. Replies
    17
    Views
    569

    Heat Loss = 33,500 BTU/Hr at -3'F Heat Gain =...

    Heat Loss = 33,500 BTU/Hr at -3'F
    Heat Gain = 18,700 BTU/HR at 92'F

    ATTACHMENT
  22. Replies
    17
    Views
    569

    Heat Loss = 33,500 BTU/Hr at -3'F Heat Gain =...

    Heat Loss = 33,500 BTU/Hr at -3'F
    Heat Gain = 18,700 BTU/HR at 82'F

    ATTACHMENT
  23. Replies
    17
    Views
    569

    Comfort guarantee relies on oversizing for many...

    Comfort guarantee relies on oversizing for many mechanical contractors.

    Heat loss is most likely in the 30,000 BTU/HR range at 9'F.
    Heat gain might be 19,000 BTU/Hr unless there are many windows...
  24. Replies
    13
    Views
    393

    If that's not some small amount of remaining pipe...

    If that's not some small amount of remaining pipe and drain pan Cleaning solution, what is it?
    :.02:
    _________________
    I thought Condensate Safety switch was required by state building codes....
  25. Reputable is Not really a part of the discussion,...

    Reputable is Not really a part of the discussion, is it?
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event