Search:

Type: Posts; User: primmers

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Thread: R12

    by primmers
    Replies
    21
    Views
    969

    the last bottle of r12 i bought was $300.

    the last bottle of r12 i bought was $300.
  2. Thread: R12

    by primmers
    Replies
    21
    Views
    969

    ^^out in the middle of nowhere...its less than...

    ^^out in the middle of nowhere...its less than r22 that for sure.
  3. Replies
    12
    Views
    542

    thanks guys..

    thanks guys..
  4. Thread: R12

    by primmers
    Replies
    21
    Views
    969

    I have plenty of customers that still can use...

    I have plenty of customers that still can use it...
  5. Replies
    12
    Views
    542

    this one is, has two slots in it for some kind of...

    this one is, has two slots in it for some kind of spanner wrench......
  6. Replies
    12
    Views
    542

    service valve jam nut tool..

    back in the old days you could use a small crescent wrench to tighten the
    jam nut to keep freon from leaking past the stem...seems the manufacture of this valve went away from the flats:gah:
    and...
  7. Replies
    4
    Views
    331

    Thanks baub...this is exactly what i need..

    Thanks baub...this is exactly what i need..
  8. Replies
    4
    Views
    331

    never mind, i found one ...whats weird is the...

    never mind, i found one ...whats weird is the number my vendor gave me is a tecumseh number I've never seen...K- something.....

    thanks anyway.
    ...
  9. Replies
    4
    Views
    331

    Tecumseh relay list..

    I have the Tecumseh hermetic compressor service handbook, and wouldn't you know it, it doesn't cover
    what relay goes into what compressor like the copeland book does,,,,,,,,


    and my vendor gave...
  10. I don't have the compressor yet..if i have the...

    I don't have the compressor yet..if i have the fitting and a valve, i will.
  11. vtp99,,yes it is.

    vtp99,,yes it is.
  12. SERVICE VALVES

    SERVICE VALVES
  13. its a walk in meat cooler..my thing was a service...

    its a walk in meat cooler..my thing was a service valve...and the lack of in a refrigeration system..
  14. and it obviously isn't an a/c application..

    and it obviously isn't an a/c application..
  15. Why don't manufactures put a suction service valve

    on all refrigeration condensing units? I just ordered a ava5539, and the book
    says the compressor is for air conditioning applications...

    :gah:
  16. Replies
    11
    Views
    720

    seems the valves failed, i have high psi on both...

    seems the valves failed, i have high psi on both sides...the guy that serviced this place was a hack and is out of business.
    my only time i was around this compressor was when i set the head...
  17. Replies
    11
    Views
    720

    thanks david..however..ive never seen a hot gas...

    thanks david..however..ive never seen a hot gas defrost except in a ice machine.....the reason I'm asking is i have
    a customer with a ah2511k thats water cooled and it went bad...the condenser is in...
  18. Replies
    11
    Views
    720

    *

    *
  19. Replies
    11
    Views
    720

    accumulators..when are they needed?

    I've seen freezers with them and as many without them..:whistle:
  20. Replies
    18
    Views
    586

    ewww good idea..

    ewww good idea..
  21. Replies
    18
    Views
    586

    irbh thats what i was hoping it was yes all the...

    irbh thats what i was hoping it was yes all the ice was in the drain pan..also i failed to mention water was draining into the refer..and there was ice in the bottom of the freezer...so I'm thinking...
  22. Replies
    18
    Views
    586

    yes thats what I'm thinking now lytning....

    yes thats what I'm thinking now lytning....
  23. Replies
    18
    Views
    586

    whirlpool # et8ghmxlq0 2 see# er1110784

    whirlpool # et8ghmxlq0 2

    see# er1110784
  24. Replies
    18
    Views
    586

    the heaters don't come on when the defrost timer...

    the heaters don't come on when the defrost timer is in defrost and theres 10 volts going to the heaters, the heaters are ok.
  25. Replies
    18
    Views
    586

    the refer was working vtp99...just has a lot of...

    the refer was working vtp99...just has a lot of ice build up
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event