  1. Replies
    12
    Views
    1,742

    Is this unit direct or belt drive, if belt drive,...

    Is this unit direct or belt drive, if belt drive, follow low voltage wires over the top of the blower and check for chaffing. I have often seen the wires shorting on the 5/16 screw heads. Is the...
  2. Replies
    34
    Views
    4,822

    The Goodman guy is at it again…

    The Goodman guy is at it again…
  3. Replies
    8
    Views
    1,044

    if the transformer is set at 230 and power is...

    if the transformer is set at 230 and power is 208, you might need to change the setup
  4. Yes I tried closing one of the service valve,but...

    Yes I tried closing one of the service valve,but no luck, what if I have too much oilin the compressor? I was thinking about changing the comp oil at the same time as the valve.
  5. The valve would not switch out of the heating...

    The valve would not switch out of the heating position, when the coil was energized i could hear the pilot valve click, i
    I also confirmed the refrigerant charge was ok. Both valves and refrigerant...
  6. reversing valve trouble, heeeeeeeeeeeeeeeeeeelp!

    I have beeb working on a new EMI 3x multi heat pump. I replaced the reversing valve and operation to the unit was restored, the following month the same thing happens, once again the the valve was...
  7. Replies
    30
    Views
    3,190

    Get something with side clips instead of...

    Get something with side clips instead of Velcro,they will last much longer, gel is best, flat caps are good so they stay on your knees.
  8. Replies
    15
    Views
    1,153

    I had a hot tub pump do that and it ended up...

    I had a hot tub pump do that and it ended up being the outlet
  9. Replies
    36
    Views
    5,942

    DONT USE IT! I used it to try to help out an old...

    DONT USE IT! I used it to try to help out an old time custumer and it ended up seizing the compressor 3 months later
  10. Replies
    23
    Views
    4,285

    Then we clean the coil and watch the top of the...

    Then we clean the coil and watch the top of the compressor pop from all the freezone that was put in.
  11. Replies
    16
    Views
    3,044

    they really must have felt like welding something?

    they really must have felt like welding something?
  12. Replies
    9
    Views
    2,978

    thats needs to be in the hall of fame, those last...

    thats needs to be in the hall of fame, those last for ever! watch out for the A stuff..
  13. Replies
    23
    Views
    4,285

    did it ever have a filter?

    did it ever have a filter?
  14. Replies
    15
    Views
    1,691

    Those red,white,blue ones from johnstone don't...

    Those red,white,blue ones from johnstone don't last very long, i went back to the oem bdp burner to prevent call backs
  15. Replies
    36
    Views
    2,144

    I had this same problem on a pg8 a couple years...

    I had this same problem on a pg8 a couple years ago, i ended up moving the HSI a little closer at a slight angle to the burner and it started lighting perfectly. To reason with it i figured vibration...
  16. Replies
    22
    Views
    2,619

    i always see these things covered in flower pots

    i always see these things covered in flower pots
  17. Replies
    7
    Views
    1,545

    this is what happens when the owner decides to...

    this is what happens when the owner decides to have his friend do the maintenance to save money but they loss in the end every time.:beat:
  18. Replies
    32
    Views
    4,108

    restarants are always the worst

    wow! did you see mad max up there?
  19. variable speed

    variable speed means the the motor ramps to maintain a set cfm, so if your filters dirty, register closed , ducts a little to small, the vs motor will speed up to a point of proper air flow across...
  20. Replies
    141
    Views
    15,491

    smwia 104 north california

    smwia 104 north california
  21. Replies
    4
    Views
    1,164

    check if the O terminal overrides the lock out...

    check if the O terminal overrides the lock out with a relay?
  22. Replies
    1
    Views
    299

    nate question

    for what reason does a heat pump have a larger outdoor coil than a air conditioner? my teacher was telling me it was to maximize pressure drop, i argued that it was to minimize pressure drop. what...
  23. Replies
    11
    Views
    743

    you will notice the blower volume change more in...

    you will notice the blower volume change more in the of cycle, if you have an xl16i and your equipment is on the large side, you might want to try setting your thermostat up so it cycles the y/lo /...
  24. Replies
    5
    Views
    558

    electric leak detectors

    i'm in the market for a electronic leak detector, does anyone know the oz per year decection a decent detector should operate at?
  25. Replies
    3
    Views
    660

    thank you,that sounds like it will work good.

    thank you,that sounds like it will work good.