    Could it be that the TrueSteam is turning the fan...

    Could it be that the TrueSteam is turning the fan on for humidity, causing increased heat losses due to the infiltration caused by the increase in fan operation? This is a setting in the TrueSteam...
  2. Replies
    49
    Views
    1,726

    Sounds like a nice set-up, just as long as the...

    Sounds like a nice set-up, just as long as the balance point for the HP Lockout is not set lower than 30* - 35*F.
  3. Thread: No Gas Savings

    by mblanks
    Replies
    36
    Views
    1,647

    Honeywell

    Honeywell
  4. Replies
    6
    Views
    2,215

    I would think the HSPF of the Trane would be...

    I would think the HSPF of the Trane would be slightly higher as it uses a TXV for the refrigerant metering in the heat mode, where the Heil uses a piston. However, probably not over 9.2. I have a...
  5. Yup! Just got a set two weeks ago. Can't see how...

    Yup! Just got a set two weeks ago. Can't see how I've managed without them. I have few jealous techs around me now. :D
    Seriously, they are an excellent toy, oops I meant tool. Very sturdy, accurate...
  6. Replies
    16
    Views
    1,546

    You are absolutely correct. We were recently told...

    You are absolutely correct. We were recently told by our sales people that these units were "Out of the box" rated SEER. Upon further investigation today (after your post) I found what you say to be...
  7. Replies
    16
    Views
    1,546

    Currently the Am Std Heritage systems are...

    Currently the Am Std Heritage systems are offering SEER ratings straight out of the box with conventional air handlers. These SEER ratings will be increased with the addition of a variable speed air...
  8. Replies
    17
    Views
    1,037

    Any source of ignition (Condensor) must be 10'...

    Any source of ignition (Condensor) must be 10' from a gas line, tank, etc. in Central VA, units must be 18" from wall and 36" from electric meter.
  9. Ditto. Ditto. Double Ditto

    Ditto.



    Ditto.



    Double Ditto
  10. Replies
    5
    Views
    543

    I apologize for missing the "Variable Speed" part...

    I apologize for missing the "Variable Speed" part of your post. :o The IAQ stat will reduce the cfm's to 350 if the humidity is high in which case would be a better choice.
  11. Replies
    19
    Views
    971

    Ask for a higher efficiency system quote. ...

    Ask for a higher efficiency system quote.



    If you've had a two stage system, then installing a single stage system will likely increase your electrical consumption.



    NO!
  12. Replies
    5
    Views
    543

    Honeywell TH8321U1006 Vision Pro 8000,Touchscreen...

    Honeywell TH8321U1006 Vision Pro 8000,Touchscreen + dehumidifier is all that you need. It will do the job very well. You can set the humidity level at the desired % and the controller will try to...
  13. Replies
    12
    Views
    504

    Heating Oil contains approx. 138,500 btu's of...

    Heating Oil contains approx. 138,500 btu's of heat per gallon, Propane contains approx. 91,000 btu's per gallon. New oil furnace efficiencies can run between 80% and 84%. Gas (Propane) furnaces can...
  14. I apologize for the way that sounded. The point...

    I apologize for the way that sounded. The point that I am trying to make is that r-410a requires special precautions and training. We had training on r-410a systems before switching to those...
  15. I would suggest an r-410A system with variable...

    I would suggest an r-410A system with variable speed blower. As stated before the variable speed systems control humidity better and are more efficient. I've been installing r-410a systems for three...