Search:

Type: Posts; User: VAV616

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    14
    Views
    2,491

    I

    Id agree you could probably use a good evaporator cleaning.
    aside from just running the chemical(hoshi is Stainless Steel) through the clean cycle for 45 min or so you should also unhook the...
  2. Replies
    130
    Views
    11,963

    And All the BUGS you got hanging around a whole...

    And All the BUGS you got hanging around a whole Cord of wood in your yard!
    :eek2:
  3. Replies
    130
    Views
    11,963

    Id just hate to see somebody spend a whole lot of...

    Id just hate to see somebody spend a whole lot of money, and then on a hotter-than-usual summer the guy is calling me because it wont keep up, or to him it seems like its not cool enough, or some...
  4. Replies
    130
    Views
    11,963

    Ah... they taught us manual J, D, and P, but id...

    Ah...
    they taught us manual J, D, and P, but id never seen S until now,
    very interesting
    ...
  5. Replies
    130
    Views
    11,963

    you guys already know the right way to do it is...

    you guys already know the right way to do it is to use manual J - it makes a big difference what kind of insulation, windows, and the angle the sun hits your specific sized overhangs that shade the...
  6. Replies
    16
    Views
    2,062

    Water Valve. /sigh the whole time I didnt...

    Water Valve.

    /sigh

    the whole time I didnt suspect it because i knew i had changed it just last year.
    turns out, after checking my records, I changed that sept 1, 2009, almost 2 years ago. ...
  7. Replies
    16
    Views
    2,062

    i did change the water filter, clean the...

    i did change the water filter, clean the condenser and use cleaner on the water circuit when i first did this one.
    so im pretty sure thee only problems left are the water valve, and this evap...
  8. Replies
    16
    Views
    2,062

    k, the amount of water that should be frozen by...

    k, the amount of water that should be frozen by the time the
    float comes down should be the same, I agree and ive been thinking
    that same thing.

    so then why is it still dropping less even...
  9. Replies
    16
    Views
    2,062

    the charge seems right on now, 10 degrees...

    the charge seems right on now, 10 degrees subcool
    superheat still hunts a little but no drastic swings.
    it supposed to drop about 13 pounds, i didnt weigh
    the batch since i redid it, its making...
  10. Replies
    16
    Views
    2,062

    you know I called several places and nobody had...

    you know I called several places and nobody had an HH smaller
    than a 163 for the liquid side.
    so i put a regular 052 on the liquid and an 164SHH on the suction

    still dont quite have all the...
  11. Replies
    8
    Views
    2,572

    /agree it annoys me when people wont spend the...

    /agree
    it annoys me when people wont spend the extra $200 some-odd bucks
    to get a new Fused disconnect.
    what you barely see is the #10 green wire reaching over to connect to the frame of the...
  12. Replies
    8
    Views
    2,572

    Well if you gowith the original maufacture you...

    Well if you gowith the original maufacture you may still need
    An adapter curb. But it will be less drastic
  13. Replies
    16
    Views
    2,062

    i found this for sporlan driers ...

    i found this for sporlan driers
    http://www.totaline.com/dl/PAGE%20K449-K453%20-%20CATCH-ALL%20DRIERS.pdf

    it says
    SPECIAL
    APPLICATIONS — A special “HH” core
    Catch-All Filter Drier is available...
  14. Replies
    16
    Views
    2,062

    yes i mean the evap temp is 0 degrees. so the...

    yes i mean the evap temp is 0 degrees. so the superheat is floating between about 10 and 30 degrees, with the sharp drop-off back to 10 then slowly working its way back up.

    what do you mean by...
  15. Replies
    16
    Views
    2,062

    Hoshizaki - txv hunting

    KM630-mae

    old r22 ref cuber.
    the water system is working fine, about 30 min cycles, but its only dropping about 60% as much weight as it should be.

    110 cond temp, 10 degrees subcooling - evap...
  16. Replies
    9
    Views
    1,112

    oddly I think hot-shot is More expensive than...

    oddly I think hot-shot is More expensive than 134a.

    was the filter/dryer one of those copper bullet style ones?
    I have been told they have small desiccant bee-bee's inside
    that may actually...
  17. Replies
    23
    Views
    2,884

    Brazed? Brazed? your gonna get out the torch...

    Brazed?
    Brazed?
    your gonna get out the torch and Braze on the gas line?

    :eek2::eek2:

    to me the more important part is that copper is bendable so all it takes is somebody to accidentally smack...
  18. Replies
    26
    Views
    4,034

    ya, vacuum leak test : | and i've had somebody...

    ya, vacuum leak test : | and i've had somebody else try to tell me that formula 409 was the best leak detector in the world lol. vicegrips ha - i hate to use flare couplings anyway. I wonder...
  19. Replies
    6
    Views
    1,086

    i have to admit ive done that before - but mine...

    i have to admit ive done that before - but mine had a service port installed :p
    It was for my brother and he didnt have the money to pay me anyway so I wasnt going to go and buy(or spend the time to...
  20. Replies
    2
    Views
    1,128

    we visited the new hockey rink where i live, It...

    we visited the new hockey rink where i live, It was an ammonia system with a brine secondary. the brine ran in a sand base under the floor, idk how big the pipes where or how close they are though.
  21. Replies
    23
    Views
    2,884

    Im gonna say this was most definitely done long...

    Im gonna say this was most definitely done long after the original inspection when it was built, either by the home owner, or some "contractor."
    To me it is just downright dangerous even if the...
  22. How to wire a single phase compressor into a three phase machine

    my all time favorite -

    first pic you are looking at two capacitors, a contactor, and the wad of duck tape that was used to hold it together in a ball and set inside the unit.
    this is a...
  23. Replies
    23
    Views
    2,884

    Attack of the killer copper Gas pipes

    sadly I see this all the time
  24. Replies
    8
    Views
    2,572

    the original was a York, if they'd of got another...

    the original was a York, if they'd of got another York, or at least something that sat the same direction it would've been ok. but the Carrier sits sideways on the old footprint. and for me, the...
  25. Replies
    8
    Views
    2,572

    "our landlord insisted we use His hvac guy"

    dont you hate it when you loose a job to somebody else, then you come back to see some crap like this : /


    and it doesnt keep up above 95 degrees,
    and that is the filter access side of the...
Results 1 to 25 of 197