  1. Thread: TEC ?

    by Daramoe
    Replies
    2
    Views
    234

    After the tec has been through a calibration...

    After the tec has been through a calibration cycle,
    Then
    (Balancer CFM reading / TEC CFM reading) * Old Flo Coeff
  2. Thread: Siemens PXM10S

    by Daramoe
    Replies
    4
    Views
    380

    What firmware revision is your panel? The PXM...

    What firmware revision is your panel? The PXM display is only supported on some of the new firmware.
  3. Replies
    4
    Views
    277

    Speaking of logic, I missed one in the example....

    Speaking of logic, I missed one in the example. You will need to add the 50, 41 to the end of the last table statement, or you will not get readings between 40 and 50.
  4. Replies
    4
    Views
    277

    Break it into 2 table statements IF (HA08CV...

    Break it into 2 table statements

    IF (HA08CV .GE. 50.) THEN TABLE(HA08CV,HA08GP,50,41,60,53,70,63,80,74,90,75) ELSE TABLE(HA08CV,HA08GP,0,0,10,1,20,7,30,17,40,27)
  5. What I think you are looking for is Slope and...

    What I think you are looking for is Slope and Intercept. Coefficient is the term used to adjust the CFM flow readings to the air balancers readings.

    That being said, while the app you are using...
  6. It's a little to involved to try to explain in a...

    It's a little to involved to try to explain in a forum (IMO). Your best bet would be to get a Apogee Field Panel Users manual. There is a very good chapter in there that explains enhanced alarming in...
  7. Replies
    6
    Views
    384

    More then likely, either there is a name...

    More then likely, either there is a name resolution issue between your client PC and the server (host file not setup if static IPs, or DNS server does not have all of the info properly registered) ,...
  8. If you know how, you can change the alarm to an...

    If you know how, you can change the alarm to an enhanced alarm, and use the schedule point as the mode point in your alarm setup.
  9. Replies
    5
    Views
    821

    The damper command point will stay in OVRD, and...

    The damper command point will stay in OVRD, and the TEC will do the calibration procedure normally, as it doesn't command the damper command. However, as the damper command is a calculated point, the...
  10. Replies
    3
    Views
    1,170

    Chapter 5 of the field panel users manual deals...

    Chapter 5 of the field panel users manual deals with nothing except the point database, and has a table going into detail on each of these points.
  11. Sounds like a trend buffer full upload. I would...

    Sounds like a trend buffer full upload. I would guess that somebody who didn't understand what they are doing, used the trend wizard to add all the points in the system in trend, and one of the...
  12. Replies
    1
    Views
    350

    Just a combination of resolution of the a-d...

    Just a combination of resolution of the a-d converter, and the auto scaling of the commander box. You didn't say what the range of the controlled device is, 0-10, 2-10, 4-20ma, etc). As to it showing...
  13. Replies
    3
    Views
    695

    The 535-741 is an 100K thermistor. The point...

    The 535-741 is an 100K thermistor. The point expansion module only supports 1K RTD (375 type) , 0-10 VDC and 4-20ma for inputs.
  14. Replies
    8
    Views
    1,608

    Are these wireless FLNs?

    Are these wireless FLNs?
  15. Replies
    3
    Views
    649

    I would suspect that it is not that the Point Exp...

    I would suspect that it is not that the Point Exp Block does not support LPACIs, but more that it does not support being on the FLN. The original Point Exp Blocks could only exist on the MEC...
  16. Replies
    5
    Views
    926

    If you upgrade your panels to 3.2 firmware, this...

    If you upgrade your panels to 3.2 firmware, this is a BTL certified firmware. The siemens panel at that time is a native bacnet device.
    There will have to be a database conversion done at the same...
  17. Replies
    5
    Views
    926

    The PX controllers can be flashed from 2.x...

    The PX controllers can be flashed from 2.x firmware to the bacnet firmware 3.2
    If the MECs and MBCs are Power MECs and MBCs, and are the ethernet variety (they have an ethernet port) then they can...
  18. Replies
    4
    Views
    824

    What revision of Insight What is the panel type...

    What revision of Insight
    What is the panel type and firmware listed in system profile.

    Your slope and intercept calculates out to 125 = 0 volts 0 = 10 volts, so I am assuming you are hooking up a...
  19. Replies
    34
    Views
    10,714

    For the PXC 24: Part Numer PXC24.2-PEF.A or ...

    For the PXC 24:
    Part Numer PXC24.2-PEF.A

    or

    For the PXC 36:
    Base Panel
    Part number PXC36-PE.A
    P2, 36 points
  20. Replies
    34
    Views
    10,714

    For which one? In each of the controllers, the P2...

    For which one? In each of the controllers, the P2 and the bacnet are different part numbers as they are different firmware loads.
  21. Replies
    34
    Views
    10,714

    The PXC Modular, the PXC 36, and the second...

    The PXC Modular, the PXC 36, and the second generation of the PXC 24 ( the one that has both a 485 and an ethernet connection on it) can be used as an AEM with the correct license. That means that...
  22. Thread: Siemens FLN

    by Daramoe
    Replies
    4
    Views
    1,172

    The database of the UCs can be backed up in...

    The database of the UCs can be backed up in system profile. The UCs have an EEprom just like the TECs, so it usually takes physical or electrical damage to get to the point that you need to replace a...
  23. Replies
    3
    Views
    1,162

    If the existing MEC and PXC are Bacnet, they you...

    If the existing MEC and PXC are Bacnet, they you should be able to discover them in a normal fashion. If they are the propriatary protocal (P2 and P1) then they would have to have the Bacnet Client...
  24. Replies
    11
    Views
    1,273

    It definitely works. I have done about a dozen...

    It definitely works. I have done about a dozen over the last 2-3 years, with very little issues.
  25. Replies
    11
    Views
    1,273

    There is an application guide, but it is a...

    There is an application guide, but it is a Proprietary Siemens manual available to thier techs only. It takes you step by step through collecting the data from the JCI system, converting it into...
Results 1 to 25 of 39