Search:

Type: Posts; User: hvacvegas

Page 1 of 20 1 2 3 4

Search: Search took 0.05 seconds.

  1. Replies
    6
    Views
    197

    It's clearly not wired correctly. I would...

    It's clearly not wired correctly.

    I would recommend the installer come back and fix the issue, or hire another tech.

    Honestly, this furnace is a pretty easy installation. Board isn't new, been...
  2. Depends on the part. Lots of paperwork to file....

    Depends on the part. Lots of paperwork to file. No money in warranty work.

    Lots of guys honor the full warranty though.
  3. Some manufacturers require it to be charged in...

    Some manufacturers require it to be charged in low stage.

    Some people just set the unit to run in the stage they need, and then change it when their done.


    Beyond that, is too DIY.
  4. Your contractor is full of crap. He was...

    Your contractor is full of crap.


    He was supposed to use the AVPTC30 with the 16 seer outdoor to get 16 seer.
    Reference #:5924471

    The reason he shows a 1.5 ton, is because it's the only thing...
  5. probably loose ductwork then. There is a test...

    probably loose ductwork then.

    There is a test that can be done though, but requires a contractor:
    Seal up all the registers in the home.
    Pressurize the ductwork with a machine that also checks...
  6. Replies
    6
    Views
    197

    He's got something wired wrong. Most likely, the...

    He's got something wired wrong.
    Most likely, the thermostat is not telling the board to run cooling.
    Cont fan takes a secondary role, and is dropped on a call for anything else.

    Probably wired...
  7. I don't know of any thermostat that varies a...

    I don't know of any thermostat that varies a condenser fan motor.
    That robertshaw doesn't change condenser fan speed.

    You have to use a low ambient, fan cycling kit.

    The honeywell 8000 has a...
  8. Replies
    8
    Views
    247

    Anything with greater than 25' height difference,...

    Anything with greater than 25' height difference, any heat pump, any unit used below 60*.

    None of that is anything official. Just my rule of thumb.
  9. I see smoke in the future. probably best to have...

    I see smoke in the future. probably best to have a professional do this.
  10. Replies
    600
    Views
    102,353

    Ran a call 2 weeks ago: "I have water leaking...

    Ran a call 2 weeks ago:
    "I have water leaking out of one of my vents."
    Show up, tell her I need to get in the attic to see the unit. She flat out tells me absolutely not, I should have informed her...
  11. Replies
    6
    Views
    287

    never even heard of them.

    never even heard of them.
  12. Replies
    15
    Views
    325

    2 years old, I think I'd change the gun.

    2 years old, I think I'd change the gun.
  13. Thread: New unit

    by hvacvegas
    Replies
    4
    Views
    288

    You have humidity issues because this is the...

    You have humidity issues because this is the coldest summer, and the highest humidity that northern kentucky/cincinnati has seen in a decade.

    We are 3x the average humidity for the summer. This...
  14. Thread: Return size

    by hvacvegas
    Replies
    3
    Views
    224

    I thought you had a modular home....? Or is...

    I thought you had a modular home....?

    Or is this a trailer? (mf=manufactured home?)
  15. Replies
    17
    Views
    593

    Absolutely not. Usually they're pompus full of...

    Absolutely not. Usually they're pompus full of BS'ers.
    Try and act like they're at the same level of HVAC knowledge, telling YOU whats wrong. Then explain to you that they're warranty pays for...
  16. Replies
    7
    Views
    218

    Supply house doesn't decide who has a warranty...

    Supply house doesn't decide who has a warranty and who doesn't.

    Control board on the ARUF series is a pretty simple thing to troubleshoot. "suspected" my rear. Either is, isn't, or hes guessing...
  17. Ditto. Sounds like someone should have got the...

    Ditto.

    Sounds like someone should have got the labor warranty.

    The Amana labor warranty pays for everything except diagnostics. Includes refrigerant. I thought Trane did also.
  18. The tech can use the compressor in the unit to...

    The tech can use the compressor in the unit to pump the REFRIGERANT back into the outdoor unit.

    The tech MUST bring his vacuum pump out, to suck the AIR out of the lines after replacing the TXV,...
  19. We don't provide DIY advice.

    We don't provide DIY advice.
  20. Replies
    14
    Views
    416

    It's not a reversing valve. He would put it in,...

    It's not a reversing valve. He would put it in, appear to be fixed for about 6 months to a year, then have the same problem.

    Call a different guy, this guy has no skill, and I couldn't beat his...
  21. Replies
    7
    Views
    419

    Probably hurt the compressor more than anything.

    Probably hurt the compressor more than anything.
  22. It takes the COMPRESSOR, which is only 1 part in...

    It takes the COMPRESSOR, which is only 1 part in the equipment, to lifetime.
    All other parts are still 10 years.


    As far as matching equipment, demand a AHRI Certificate that proves your...
  23. Replies
    9
    Views
    460

    Boys Boys Boys. Can't we all just agree that...

    Boys Boys Boys. Can't we all just agree that copper coils suck and move on?
  24. I'd go with the ASX16, non communicating. Not...

    I'd go with the ASX16, non communicating. Not alot of bells and whistles, not alot to go wrong.
    The board in the ASXC models is insanely expensive, with low part avail. from our local dist.

    I...
  25. Replies
    49
    Views
    1,193

    If the criminals are so bad, then how is not...

    If the criminals are so bad, then how is not having a gun going to help?