    You must not have seen the secondary heat...

    You must not have seen the secondary heat exchangers fall apart and fill the homes with CO.

    I did
  2. Replies
    20
    Views
    2,372

    The cost of maintenance on a pulse that is almost...

    The cost of maintenance on a pulse that is almost 20 yrs old doesn't make sense to me. The extra 2 or 3 % in efficiency doesn't cover that cost.
  3. Replies
    66
    Views
    6,839

    Sorry up front but I can't assume anything If...

    Sorry up front but I can't assume anything

    If you brazed the piping with the sensing bulbs attached you may have over heated the sensing bulb and damaged the valve.

    If you monitor the suction...
  4. Replies
    4
    Views
    707

    In Tranes defense the reason it comes with a 17 x...

    In Tranes defense the reason it comes with a 17 x 25 filter is that is the dimensions of the bottom of the cabinet and if you were to use a bottom return this is the the size filter you would need....
  5. Replies
    3
    Views
    702

    Make sure the aqua stat is on the hot water in...

    Make sure the aqua stat is on the hot water in line and not the water out line also see if you can set the differencial on the aquastat to at least 20*

    Air flow and ducts being too small and or...
  6. Replies
    12
    Views
    1,028

    Carrier will give tighter and better...

    Carrier will give tighter and better control/comfort
    Trane is less $$$
    Whats more important to you?
  7. The possibility of hum operating in cooling mode...

    The possibility of hum operating in cooling mode may exist if you wire it to operate with fan only
  8. Replies
    4
    Views
    619

    Carrier infinity goes to 21 seer very $$$

    Carrier infinity goes to 21 seer very $$$
  9. Replies
    17
    Views
    1,401

    3.5 tons of air sounds a little light for 2600 sq...

    3.5 tons of air sounds a little light for 2600 sq ft living space in which 400 of that could double as a solar gain experiment. mini split is for you.
  10. Replies
    1
    Views
    1,335

    Try York

    Try York
  11. Replies
    5
    Views
    968

    I know it's late but if your still having...

    I know it's late but if your still having trouble, you should monitor suction line temp right behind each comp and one at a time shut off each comp and see if the temp rises quickly and if it does...