  1. Replies
    3
    Views
    1,050

    Read the directions!

    Read the directions!
  2. Replies
    27
    Views
    4,094

    It's been awhile since I've been on here, but why...

    It's been awhile since I've been on here, but why is no one screaming for superheat, subcooling and amp draw?
  3. Replies
    23
    Views
    1,421

    UNLESS, someone changed the reversing valve, and...

    UNLESS, someone changed the reversing valve, and accidently put it in backwards, so added a relay sending Y to energize the RV in heat to cover his tracks, so it wooshed everytime call for heat...
  4. Replies
    5
    Views
    593

    What the heck is an RGF?

    What the heck is an RGF?
  5. Underfeeding due to a bad txv is my guess. IMO...

    Underfeeding due to a bad txv is my guess. IMO you proved it by the high head in heating after adding charge.
  6. Underfeeding indoor txv.

    Underfeeding indoor txv.
  7. Thread: Rollout Switch

    by Dr.phil
    Replies
    11
    Views
    1,456

    No, it's the rollout switch. A restricted hx...

    No, it's the rollout switch. A restricted hx doesn't allow for a proper draft, so it rolls out.
  8. Thread: Rollout Switch

    by Dr.phil
    Replies
    11
    Views
    1,456

    Contact your ICP rep to tell you how to clean the...

    Contact your ICP rep to tell you how to clean the oil out of the secondary heat exchanger.
  9. Thread: Rollout Switch

    by Dr.phil
    Replies
    11
    Views
    1,456

    What position are the installs?

    What position are the installs?
  10. Thread: Rollout switch

    by Dr.phil
    Replies
    14
    Views
    1,377

    What furnace are you talking about? Would make a...

    What furnace are you talking about? Would make a big difference in my thought process.
  11. Replies
    11
    Views
    675

    The blower needs to be pulled. Keep the filter...

    The blower needs to be pulled. Keep the filter changed, and you won't have to worry about it.
  12. Replies
    112
    Views
    10,764

    The round hole where they are connected. The ring...

    The round hole where they are connected. The ring pops off, just like the Goodmans. They had a service bulletin on them, and a recall at one time.
  13. Replies
    15
    Views
    3,178

    We've decided to use dye, unless the system is...

    We've decided to use dye, unless the system is flat. Then we use a little r22 to flavor the nitrogen. I'm tired of buying new detectors to find they all miss small 410a leaks.
  14. Replies
    12
    Views
    1,494

    Our ICP reps seem to be a little more honest,...

    Our ICP reps seem to be a little more honest, they told us last time, a new oil they tried, emulsified and wouldn't drain with the water. This time the factory guy told me he thought someone found an...
  15. Replies
    14
    Views
    716

    Love that kid!

    Love that kid!
  16. Replies
    12
    Views
    1,494

    Not sure about the Carrier number, but the Bryant...

    Not sure about the Carrier number, but the Bryant rep was surprised when I told him about it today. Didn't argue about the warrenty request though.
  17. Replies
    6
    Views
    422

    Yes.

    Yes.
  18. Replies
    12
    Views
    1,494

    Heads up Guys. Tempstar, Bryant.

    Return of an old problem, Tempstar T9MPX, Bryant 359AAV furnaces, with rollout problems on startup. Listen for gurgling in the secondary hx, indicating the return of the oil sludge. Thought they...
  19. Replies
    55
    Views
    1,969

    Poll: This is a perfect example of a company passing...

    This is a perfect example of a company passing along a cost to the consumer that is the unintended consequence of government action. Just wait until they make the corporations pay their fair share.
  20. Replies
    6
    Views
    800

    In my experience, when I think I'm all that, I'll...

    In my experience, when I think I'm all that, I'll do something stupid that humbles the heck out of me. :grin2:
  21. Replies
    14
    Views
    1,865

    What?

    What?
  22. Replies
    14
    Views
    2,558

    No solenoid, just a valve with an equalizer....

    No solenoid, just a valve with an equalizer. Didn't let it run long enough to freeze the evap. Compressor was flooding so bad I shut it off. Compressed air temp was 105f. This unit was added to the...
  23. Replies
    14
    Views
    2,558

    Suction pressure is 68psi. Like I said both power...

    Suction pressure is 68psi. Like I said both power elements on the txv and the hot gas valve, but not the bodies, have been replaced, along with two compressors. By another co. Now I need to get to...
  24. Replies
    14
    Views
    2,558

    That's what's bugging me. Txv is suposed to be...

    That's what's bugging me. Txv is suposed to be factory set. I think it is the txv, because the pressure is in the green.
  25. Replies
    24
    Views
    1,829

    Can you say, Yearly Maintenance?

    Can you say, Yearly Maintenance?