  1. Replies
    42
    Views
    14,509

    During my first interview with a commercial...

    During my first interview with a commercial service company I literally had to take a 50-100 point written exam. Questions ranged from anything like others have listed, to me having to fill in a...
  2. Thread: stink bugs

    by thegame
    Replies
    30
    Views
    3,361

    The story around here about the stink bugs was...

    The story around here about the stink bugs was this... (Whether or not true???) The bugs were brought over from Asia or wherever to take care of the lady bug problem we had a few years back. Now,...
  3. Thread: stink bugs

    by thegame
    Replies
    30
    Views
    3,361

    Our area is one of the worst affected it seems. ...

    Our area is one of the worst affected it seems. On the same roof, I had two RTU's that were completely infested. Same problem on both units. The darn things got in behind the coils of the indoor...
  4. Replies
    101
    Views
    3,048

    We do (Steelers) always have a lot of problems...

    We do (Steelers) always have a lot of problems with the Pats. I don't think they're that much better than we are. Either way, we're not going to be able to turn the ball over and the special teams...
  5. Replies
    63
    Views
    8,475

    I am going to be doing a field comparison between...

    I am going to be doing a field comparison between the Tif ZX, a Fieldpiece SRL2K7, and possibly an Inficon D-tek Select. I'm a tech just like everyone in here and not affiliated with any vendors or...
  6. Replies
    63
    Views
    8,475

    Wow, this thread really took off recently, lol. ...

    Wow, this thread really took off recently, lol. Since I made the thread and haven't posted anything back since, here are my thoughts on the ZX...

    I like this detector and got a pretty good...
  7. Replies
    4
    Views
    1,065

    The way I understand things, if you have a type 1...

    The way I understand things, if you have a type 1 certification, you are certified to use any refrigerant including R404a. You have to watch out though because the type 1 only covers small...
  8. Replies
    7
    Views
    1,599

    We were always taught that there must be a...

    We were always taught that there must be a diconnect within sight of the outdoor unit. That might be local code, but I thought it was national code.
  9. If you don't end up finding it, ...

    If you don't end up finding it,

    http://www.amazon.com/Institute-Section-Certification-Preparatory-Manual/dp/1930044003/ref=sr_1_3?ie=UTF8&s=books&qid=1283884072&sr=8-3

    This is the book I used....
  10. Replies
    10
    Views
    2,679

    I agree. I have done it on the tree as well, but...

    I agree. I have done it on the tree as well, but this seems to cause fluctuations when I valve off the pump. Plus, I do not want to allow all of my connections an oportunity to leak while holding a...
  11. Replies
    85
    Views
    4,225

    Fast cars and heavy metal music. Also, I did...

    Fast cars and heavy metal music.

    Also, I did not cope with stress real well and was recommended Yoga. I know it sounds gay, but believe it or not, it honestly helps.
  12. Replies
    14
    Views
    1,388

    I use the one on the far right with a YJ 6 cfm...

    I use the one on the far right with a YJ 6 cfm pump and 2 core remover tools. I've tried my micron gauge just about everywhere I could and the easiest seems to be the port on the tree. I break with...
  13. Replies
    23
    Views
    1,849

    I have a 971 and it's the best I've ever used. I...

    I have a 971 and it's the best I've ever used. I find it surprising that someone said it was slow to respond. Mine responds very quickly. I was amazed when comparing it to a few other less...
  14. Replies
    58
    Views
    2,774

    Honestly, a coworker and myself were talking...

    Honestly, a coworker and myself were talking about digital guages the other day. Is that really something a rookie should have? Or should he learn how to go oldschool with analogues and...
  15. Replies
    29
    Views
    6,047

    I don't have half the experience of many of you,...

    I don't have half the experience of many of you, but I actually use NRP low loss fittings and YJ ball valves. I trust the ball valves a lot more. I read somewhere that someone didn't recommend...
  16. Replies
    63
    Views
    4,611

    This is a very difficult one. He's just trying...

    This is a very difficult one. He's just trying to make a living. Then again, he's trying to make a living at the expense of someone else trying to make a living. I have a few years under my belt,...
  17. Thread: nice weather..

    by thegame
    Replies
    8
    Views
    607

    Unfortunately we don't see many 100 degree days...

    Unfortunately we don't see many 100 degree days in Pittsburgh, but it never gets too hot for me. All my coworkers complain when they have to work in the 90 degree weather. I'm just the opposite. ...
  18. Replies
    13
    Views
    2,182

    I'm working on this myself. In the business...

    I'm working on this myself. In the business already and still in school. I think I know the answer to the question though.
  19. Replies
    12
    Views
    953

    We learned about these in school, but I can...

    We learned about these in school, but I can honestly say I've never seen one or had to deal with this.
  20. Replies
    12
    Views
    1,555

    I was going to say, his condensing temp is right...

    I was going to say, his condensing temp is right around ambient (188 psi R22= 96*F). Subcooling 10 degrees below ambient? What kind of amperage was the compressor drawing?
  21. I have a cheap digital Supco manometer. It does...

    I have a cheap digital Supco manometer. It does the job, but is rediculously large in size. I wanted to go with a 510, but I needed a new one quickly and only had one choice for digital.

    For a...
  22. Replies
    30
    Views
    3,593

    I just got a new YJ SuperEvac 6 CFM pump. I do a...

    I just got a new YJ SuperEvac 6 CFM pump. I do a lot of RTU's and was very impressed with the new pump. It is a little pricey at around $400, but I didn't really like the quality of some of the...
  23. Replies
    6
    Views
    1,457

    I sent you an email earlier. Very interested in...

    I sent you an email earlier. Very interested in the YJ recovery unit. I'd like some pics too.
  24. Replies
    63
    Views
    8,475

    Tif ZX-1 vs Tif ZX

    Hey guys

    I just purchased a Tif ZX-1 leak detector from my supply house because it was on special. They got one in for me and I took it home only to realize that it's the Tif ZX model. I looked...
  25. Replies
    6
    Views
    713

    I was considering purchasing one of these. Looks...

    I was considering purchasing one of these. Looks like I may want to hold off or look somewhere else.