  1. FWIW I have a single 2 ton for my 1600sqft house...

    FWIW I have a single 2 ton for my 1600sqft house in OKC. MUCH hotter than MA. My AC runs less than 1/2 the time when it's 85F, Above 95F it runs 100%.

    You have NO AC now? I can't see a house that...
  2. It's a CYA thing. Contractor wants to make 120%...

    It's a CYA thing. Contractor wants to make 120% sure that the system will keep up even when well above design conditions. The last thing he wants is a call that the system won't keep up.
  3. Glad it all worked out. Surprised they went up a...

    Glad it all worked out. Surprised they went up a full ton in cooling size instead of reducing the load 0.1 tons. The nice thing about VS equipment is is ability to run at just the right capacity.
  4. Here in Oklahoma we have3 be been through a month...

    Here in Oklahoma we have3 be been through a month of cool wet weather
    Not cold enough for heat or warm enough for AC. Record rainfall for the month. Wishing I had one of those ultra - aire units.
  5. A 4 ton should be PLENTY for 2600sqft built in...

    A 4 ton should be PLENTY for 2600sqft built in 2002. May even need less. A load calculation will let you know.
  6. Don't over think it. Sqft of entire house? Total...

    Don't over think it. Sqft of entire house? Total tons of all systems?
  7. I may have said too much already. Hopefully your...

    I may have said too much already. Hopefully your AC guy can figure it out.

    Be sure everything works and the condenser runs the "right direction" in heating and cooling. Have him verify emergency...
  8. Agree with others, the "up to" SEER is very...

    Agree with others, the "up to" SEER is very different than delivered real work performance. If you aren't getting at least 700sqft out of each ton of AC, some house/ductwork tightening will help a...
  9. The jumper from W1 to Y brings the condenser on...

    The jumper from W1 to Y brings the condenser on in heating mode, has nothing to do with 2 stage heat pump.
  10. Only 1 out of 10 programmable thermostats is set...

    Only 1 out of 10 programmable thermostats is set correctly. Most are simply left on "hold" mode.
  11. A 2.5 ton would probably do the job if the...

    A 2.5 ton would probably do the job if the insulation is good and the house is tight. You *may* loose a few degrees on the hottest afternoons, but would get excellent humidity control the other 98%...
  12. A properly sized setup should run no more than...

    A properly sized setup should run no more than twice an hour and still be able to keep the temp within 2 degrees of setpoint. Oversized systems will have to let the temp droop more than 2 degrees if...
  13. Replies
    12
    Views
    744

    If 76k wont heat 3200sqft @ a 13f design temp...

    If 76k wont heat 3200sqft @ a 13f design temp then you need to find and fix the leaks in the house. 76k is a LOT of heat leakage, if you have MORE than that, then the large leaks should be easy to...
  14. Look at KWH and Therms, your use probably dropped...

    Look at KWH and Therms, your use probably dropped more than 10%. A lot of utilities have rate increases in the past year. What city is the house located? I would have used the extra $$ to split...
  15. Replies
    19
    Views
    1,298

    What happens if the system can't keep up on those...

    What happens if the system can't keep up on those design days? The temp will slip a few degrees, thermal mass will normally prevent the house from getting too hot. Humidity will be low due to LONG...
  16. Replies
    22
    Views
    1,571

    Double RPM is 8 times the HP. It's CUBED, not...

    Double RPM is 8 times the HP. It's CUBED, not squared.
    http://www.freecalc.com/fansfram.htm
  17. Replies
    22
    Views
    1,571

    I doubt he'll even spend the $$$ on the motor...

    I doubt he'll even spend the $$$ on the motor unless the original doesn't provide enough CFM to stop the coil from freezing up.
  18. Replies
    22
    Views
    1,571

    I'm sure it can be done, it will just be noisy...

    I'm sure it can be done, it will just be noisy and inefficient. Large blades moving at slower speeds tend to be more efficient than small blades turning at high speeds. But larger wheels cost more as...
  19. Replies
    20
    Views
    1,065

    Where I'm CA are you? If heat isn't used very...

    Where I'm CA are you? If heat isn't used very much I question the need for a 70k furnace.
  20. Replies
    22
    Views
    1,571

    Probably has a 10x7 or 10x8 wheel, getting...

    Probably has a 10x7 or 10x8 wheel, getting 1600cfm through it at a decent static pressure using any type of motor is gonna be fun... 1600cfm normally needs at least a 10x10 wheel.
  21. Replies
    20
    Views
    1,065

    4ton cool/70k heat is way overkill for a typical...

    4ton cool/70k heat is way overkill for a typical 1307sqft house. Unless your house is extremely leaky or in an extreme part of CA, it shouldn't need that large of a system.
  22. Replies
    6
    Views
    681

    70 degree DRY or HUMID air?

    70 degree DRY or HUMID air?
  23. Thread: DEC Star ECM

    by 54regcab
    Replies
    3
    Views
    886

    Why no backward inclined blades? That's where the...

    Why no backward inclined blades? That's where the REAL savings are, forward curved blades are only about 65% mechanically efficient vs 85% for backward curved.
  24. Replies
    22
    Views
    1,571

    With a low enough static enough pressure the...

    With a low enough static enough pressure the larger motor running at 1075RPM may deliver the 1600CFM. Keep in mind that lower static = higher airflow, but requires more HP from the motor to keep the...
  25. Replies
    19
    Views
    1,167

    117f is an OCCASIONAL temp, what is design temp...

    117f is an OCCASIONAL temp, what is design temp for your area? Dropping for a 5ton down to a 4ton (20% reduction) will save you the same as a 2 point SEER increase (20% increase). Don't go too small...
  26. Replies
    37
    Views
    1,932

    A 100k furnace is a complete waste for Oklahoma. ...

    A 100k furnace is a complete waste for Oklahoma. If you can cool the house with a 5 ton AC, you can heat it with an 80k furnace.
  27. Replies
    37
    Views
    1,932

    60k furnace with outdoor temps below zero. Must...

    60k furnace with outdoor temps below zero. Must be either a small or tight house.

    Says a lot about how stupid a 100k furnace looks in a climate that doesn't even get below freezing. We have a...
  28. Replies
    37
    Views
    1,932

    You have to be less than 30% oversized on order...

    You have to be less than 30% oversized on order to have the ideal high/low switching during cold weather. This means a furnace that's about 1/2 the size typically installed. How many furnaces have...
  29. Replies
    37
    Views
    1,932

    Old thermostats had a 1 or 2 degree differential...

    Old thermostats had a 1 or 2 degree differential to kick in 2nd stage. Newer stats are normally timed and watch how quickly the temp rises with just stage 1 calling. If the difference is over 3...
  30. Replies
    6
    Views
    814

    Looks like a simple amp clamp. Make sure the TED...

    Looks like a simple amp clamp. Make sure the TED knows it's hooked to a 240v source. AC units average about 1,000W per ton @ 95f outdoor temp. Newer units less, older units more. Cooler temps reduce...
  31. Replies
    37
    Views
    1,932

    Most 2 stage furnaces have low fire thats about...

    Most 2 stage furnaces have low fire thats about 70% of full capacity. Most furnaces are oversized by at least 30% so the 2nd stage never kicks in unless the system is recovering from setback. The...
  32. Replies
    46
    Views
    6,437

    Want reliability? Install BASIC models that don't...

    Want reliability? Install BASIC models that don't have ECM motors or fancy control boards. Correctly size them with proper airflow and heat exchangers/compressors will last a LONG time.

    I'm on...
  33. Replies
    72
    Views
    9,659

    Silly car manufacturers developing ideas to save...

    Silly car manufacturers developing ideas to save MPG when all they have to do is add a magnet to the fuel line. The amazon reviews are mind boggling, people actually believe it works...
  34. Replies
    72
    Views
    9,659

    You can buy some of those gas saver magnets that...

    You can buy some of those gas saver magnets that attach to your fuel line.... ...
  35. 2200/4.5 = 489sqft per ton. Agreed it looks like...

    2200/4.5 = 489sqft per ton. Agreed it looks like a "reverse engineered" load calc to hit 500sqft per ton.
  36. Replies
    11
    Views
    529

    Modulating furnace with PSC? I'm surprised they...

    Modulating furnace with PSC? I'm surprised they can get blower speed low enough when at minimum firing rate.
  37. udarrell I doubt his original system was...

    udarrell I doubt his original system was delivering 4 tons, much less 5. Most likely sized "500sqft per ton" but actually needs much less.
  38. Replies
    72
    Views
    9,659

    It's all good. Every time they bump the tread we...

    It's all good. Every time they bump the tread we call out the product...
  39. Replies
    72
    Views
    9,659

    Going from a 5 ton to a 4 ton will save 20% on...

    Going from a 5 ton to a 4 ton will save 20% on your bill. Most of the time you won't notice the smaller unit since it's rare to find a 5 ton system that actually delivers the full 2,000cfm. Most are...
  40. Replies
    72
    Views
    9,659

    Replacing the fan relay with a 20-110 sequencer...

    Replacing the fan relay with a 20-110 sequencer accomplishes the same thing.
  41. Replies
    96
    Views
    3,551

    There you have it. Out of the 3.5tons on your...

    There you have it. Out of the 3.5tons on your current system you may only be getting 70% or 2.5 delivered tons.

    My house is not super tight but I have fixed all the big leaks. Leaks are easier to...
  42. Replies
    96
    Views
    3,551

    And that's why the oversizing madness continues....

    And that's why the oversizing madness continues. With a correctly sized system no shortcuts allowed. It must operate at its rated capacity, not the 2/3's that's typically delivered. If your condenser...
  43. Replies
    96
    Views
    3,551

    Absolutely you can "precool" to get ahead. My old...

    Absolutely you can "precool" to get ahead. My old AC was a 3 ton, way oversized. Run the ceiling fans on high speed if need be. It amazes me how many crank the thermostat down and leave the fans on...
  44. Replies
    96
    Views
    3,551

    Wall insulation is standard 1999 construction,...

    Wall insulation is standard 1999 construction, 2x4 wall R11 or R13, not sure which. No tree cover at all, medium Grey shingles.

    Slip is how much the house falls behind Thermostat Setpoint. My AC...
  45. Replies
    96
    Views
    3,551

    Plain 14 SEER AC with gas furnace. No VS motor.

    Plain 14 SEER AC with gas furnace. No VS motor.
  46. Replies
    96
    Views
    3,551

    Yup. 500sqft per ton reverse engineered into the...

    Yup. 500sqft per ton reverse engineered into the "Man J". Keep in mind my own 1600sqft house is 2 tons and good for 95/75 (20 degrees). "Slip" is not proportional to outdoor temp due to thermal mass....
  47. Replies
    9
    Views
    486

    If you want even heating on both floors, then...

    If you want even heating on both floors, then install a small system on each floor instead of trying to do it all with 1 large system.
  48. I haven't either. All the MH parks around here...

    I haven't either. All the MH parks around here are electric resistance heat. Mobile homes out in the country use propane sometimes.
  49. Replies
    12
    Views
    1,142

    Properly installed the 2.5 ton should be plenty...

    Properly installed the 2.5 ton should be plenty to keep you warm/cool. Should save some $$$ also with plenum repairs.
  50. Are you thinking improper LP conversion?

    Are you thinking improper LP conversion?