Search:

Type: Posts; User: CFC Mafia

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    10
    Views
    511

    Has anyone ever seen a JCI 5800 controller with...

    Has anyone ever seen a JCI 5800 controller with no jumpers on the re-adjust? The DA-RA ones are in but the others are missing. I dont think Ive ever seen it done that way. Is this wrong or right?
  2. Replies
    10
    Views
    511

    Thanks guys, For what we are doing, 95% is going...

    Thanks guys,
    For what we are doing, 95% is going to be T-4000 T-stats.
    These buildings have fallen victim to the "I'm not familiar with pneumatics, but if I disconnect the linkage the cooling...
  3. Replies
    10
    Views
    511

    Looks like KELE makes a nice kit.

    Looks like KELE makes a nice kit.
  4. Replies
    10
    Views
    511

    JCI Pnuematics

    Does JCI still offer a calibration kit for their stats and Receiver controllers?
    I've been trying to straighten out some old controls and I am going to order a bunch of spare parts. I would like to...
  5. I sent your address to Glenn, he should be...

    I sent your address to Glenn, he should be emailing you.
  6. I have a good friend of mine that is a Licensed...

    I have a good friend of mine that is a Licensed reputable contractor in Irving. IM me your phone number and I will pass it on.
  7. Replies
    63
    Views
    2,943

    I have about 50 of these units that we rent out...

    I have about 50 of these units that we rent out to to US Military for desert field training. What has happened to some of my units is if the evaporator load is really high or if the head pressure is...
  8. Replies
    3
    Views
    1,421

    Yes they are for rent.

    Yes they are for rent.
  9. Replies
    87
    Views
    4,104

    [QUOTE=klove;9681692]You've never seen multiple...

    [QUOTE=klove;9681692]You've never seen multiple condensing units on a single air handler? Or never staged compressors? I'll leave those two questions alone.

    My point was on such a small system. I...
  10. Replies
    87
    Views
    4,104

    I apologize for implying that his company would...

    I apologize for implying that his company would not follow through. I'm sure as a licensed and insured contractor he recognizes the responsibility to do the right thing.

    From what it sounds...
  11. Replies
    87
    Views
    4,104

    That sounds like a job that will technically work...

    That sounds like a job that will technically work for the sign off. The customer will complain until about october. Then it will be cold and it will be off but hey, the customer is not complaining....
  12. Water source heat pumps will give you the most...

    Water source heat pumps will give you the most options. ( Independent control , re-use of boiler and tower, potential for energy credits) If you can get a replacement AHU at a substantial savings....
  13. Replies
    87
    Views
    4,104

    I would lean towards being overcharged. But I...

    I would lean towards being overcharged.
    But I have seen on some of our rental units when the evaporator load is high. The scroll compressor will blow the oil into the condenser. It will look like...
  14. Replies
    3
    Views
    1,421

    Trane RTAA Rental packages

    Got 2 of these, cleaned em up and rigged em out.
  15. Replies
    0
    Views
    630

    YCAS250 Rental Package

    Just finished this one. It is a 2001 Style "F" but was never installed. Touched up the paint and she was ready to go.