  1. Infocom Comm4 driver and Precedent units

    I'm trying to bring some Trane Precedent units into Niagara AX with the Infocom Comm4 driver and have a quick question about how to remotely get them to control. I can write to the occupied heating...
  2. Replies
    10
    Views
    1,474

    We do offer R2 certification, if you visit the...

    We do offer R2 certification, if you visit the site below, look for Environmental Systems. No classes are currently scheduled, but they are offered if enough interest is there.
    ...
  3. Modbus communication to Cutler Hammer Pow R Command

    Has anyone had any luck communicating with the Cutler Hammer BCB smart breakers? I'm not having much luck finding any info, and their tech support has just forwarded me literature that I had already...
  4. Replies
    13
    Views
    1,422

    Go to the Tridium website, and look under...

    Go to the Tridium website, and look under Training, Training Partners. There are at least two other sources, Cochrane in Michigan, and Environmental Systems in Wisconsin that do certification.
  5. Replies
    12
    Views
    753

    Johnson FX-40 question

    If I have a JCI system that currently has an NCM, and a NIE could I hang a FX-40 in the N2 trunk and have it log data from the other N2 devices without causing any problems with the NCM or NIE? ...
  6. Replies
    83
    Views
    10,419

    You can put a Tridium AX or R2 Jace in with a...

    You can put a Tridium AX or R2 Jace in with a Smart II driver. We do them all the time.
  7. Replies
    7
    Views
    951

    could you please e-mail it to me too? Thank...

    could you please e-mail it to me too?

    Thank you.
  8. Replies
    7
    Views
    1,030

    For the R2 Jaces, there is a possible option, but...

    For the R2 Jaces, there is a possible option, but hard to do sometimes:

    Tridium will re-license it for you (or a purchaser) to access if you can provide a letter from an officer of the end user...
  9. Replies
    8
    Views
    835

    It depends on the version you are running, but...

    It depends on the version you are running, but there was an updated Workbench jar file a while back, you should be able to find out the details on Niagara Central
  10. Replies
    2
    Views
    664

    The BACnet gateways for Carrier are pretty easy...

    The BACnet gateways for Carrier are pretty easy to use, but are fairly expensive (slightly north of $500 per unit). ALC makes the card, you can select modbus or BACnet ms/tp. It gives you 60...
  11. Replies
    5
    Views
    972

    There is one possible other option, use a R2 jace...

    There is one possible other option, use a R2 jace with the CCN driver, and export everything as BACnet into an AX jace.
  12. Andover Continuum integration question

    I'm bringing some Andover b3865/66 vav boxes into a R2 jace, I was able to learn the devices in, but no points were created. Is there a standard set of AI/AV/AO/BI/BV/BO points that I can manually...
  13. Replies
    20
    Views
    7,078

    Are you using the Modlink, or Intellicomfort?

    Are you using the Modlink, or Intellicomfort?
  14. Replies
    5
    Views
    1,655

    The NCRS migration server works pretty good with...

    The NCRS migration server works pretty good with R2. Depending on the number of controllers you are migrating, it can get pretty expensive. It is a pretty good integration, there are some...
  15. Replies
    1
    Views
    438

    if you use the element setup utility software,...

    if you use the element setup utility software, you can change the address to anything you want
  16. Replies
    17
    Views
    1,822

    You could reset the outdoor air level based on...

    You could reset the outdoor air level based on the PPM level, a simple programmable controller, with fan status (one binary input), CO2 level (one analog input), and a damper output (one analog...
  17. Replies
    6
    Views
    693

    Some of that depends on the system you are...

    Some of that depends on the system you are working with. Often, the Master will pass the token to the Slave, and process all data requests/read the data from the Slave, before passing it to the next...
  18. Replies
    4
    Views
    1,554

    It sounds like you've tried all of the different...

    It sounds like you've tried all of the different passwords, is there an IT person that can log in to the machine with a different account to see if there is something blocking you from logging in. ...
  19. Replies
    2
    Views
    755

    no major issues on the tridium side...lennox had...

    no major issues on the tridium side...lennox had some issues with their lon card on earlier revisions, those are supposed to be fixed now. the only thing that was out of the ordinary, when binding...
  20. Replies
    10
    Views
    1,026

    the ccn to lon gateway still resides on the ccn...

    the ccn to lon gateway still resides on the ccn bus, it will still communicate at 9600 baud. The ccn bus is still a polling service, the more devices you have, the longer it will take to complete a...
  21. Replies
    4
    Views
    1,606

    If I remember correctly, the Carrier translator...

    If I remember correctly, the Carrier translator only converts ccn to bacnet or modbus. You use configuration tables to map the CCN points to bacnet points. To bring York chillers into a CCN system,...
  22. All you should have to do is match, commission,...

    All you should have to do is match, commission, bind, download, reset, and maybe a fetch. Never had any issues. Which release are you doing this in?
  23. Replies
    10
    Views
    946

    The 0,0 search only works when you are plugged...

    The 0,0 search only works when you are plugged directly into a single controller.


    Under ComfortVIEW, look for Bus Services, and do an update poll. It will scan the bus, and show you which...
  24. Replies
    1
    Views
    551

    use the log template

    use the log template
  25. Replies
    16
    Views
    3,732

    In the past, I have retrofitted these the hard...

    In the past, I have retrofitted these the hard way. If you drop the bottom off of the box, you can remove all the guts, and mount a new damper in the box, drill a hole for the shaft, patch up any...