Search:

Type: Posts; User: workhc

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    279

    Carrier 25 Hna6 heat pump

    Fault code 72, Bristol compressor overheated, anyone having trouble with this compressor, I heard from rep that Bristol is having problems with 2 speed compressor
  2. Replies
    11
    Views
    1,529

    ran in high fire 10 minutes, been installed since...

    ran in high fire 10 minutes, been installed since 2008 and trouble free
  3. Replies
    11
    Views
    1,529

    carrier fault code 33 on 58mvc

    have fault code 33 on carrier mvc, works fine in high fire, ran fine for 10 minutes each in low and medium fire through the check out in infinity controller. brand new infinity air purifier filter...
  4. Replies
    7
    Views
    1,360

    Hot or cold water for humidifier

    been in this business for 20 years and have been hearing from other contractors that they hook up humidifiers on hot water line. i have always hooked up to cold water, any thoughts from others would...
  5. Replies
    0
    Views
    578

    59tp5 carrier furnace

    new furnace is out, just wondering if anyone has installed this model yet and what are the thoughts good or bad.
  6. Replies
    4
    Views
    682

    if system has a txv, chances are thats your...

    if system has a txv, chances are thats your problem. had the same situation last week on a ac system. suction was 40, head was 225. pulled apart and evap coil was half frosted up, replaced txv and...
  7. Replies
    6
    Views
    1,246

    really good chance the evap coil is leaking, its...

    really good chance the evap coil is leaking, its called formicary corrosion, replace with a tin plated coil
  8. Replies
    14
    Views
    651

    going tomorrow to spray water on condenser coil...

    going tomorrow to spray water on condenser coil while unit runs and see what happens. if continues to run i am going to hook up a sprinkler on the coil for 24 hrs and see what happens
  9. Replies
    14
    Views
    651

    all worked fine with old unit till 2 days ago...

    all worked fine with old unit till 2 days ago when compressor crapped out. only replaced condenser because air handler is in attic and its 130 in the attic
  10. Replies
    14
    Views
    651

    not a home owner, it is an r-22 unit, charge was...

    not a home owner, it is an r-22 unit, charge was weighed in according to factory recomendation plus 12 ounces for addition 20 feet of lineset
  11. Replies
    14
    Views
    651

    compressor overload on new install

    installed a new dry ship goodman today and weighed in charge. operating pressures were 110 suction and 350 head. needless to say the compressor overloaded after 5 minutes of running. outdoor temp was...
  12. Replies
    10
    Views
    661

    most of my leakers are carrier just a couple yorks

    most of my leakers are carrier just a couple yorks
  13. Replies
    10
    Views
    661

    its ridiculous replacing coils that are 1 2 and...

    its ridiculous replacing coils that are 1 2 and 3years old because of this, seems every day i have at least 1 call of a no ac because of this damn problem. you sell new systems to update and then...
  14. Replies
    10
    Views
    661

    formicary corrossion

    is it just me or is formicary corrossion a legit problem or is it really just cheaper copper causing tons of evap coil leaks
  15. Replies
    5
    Views
    563

    heat pump question

    working on a heat pump today and unit is stuck in heat mode. i am not real keen on heat pump service. i unhooked the wire to the o terminal in heat mode and the unit did not shift to the cool side,...
  16. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,594

    not worried about seer rating, just wondering if...

    not worried about seer rating, just wondering if the txv is required. i know york requires a txv with the 14.5 seer unit. i am used to carrier, all of their coils have factory installed txv
  17. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,594

    what are your thoughts on this model

    what are your thoughts on this model
  18. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,594

    goodman ssx 14

    does this model require the use of a txv or can you use piston
  19. Replies
    15
    Views
    989

    the only reason the rollout switch in burner box...

    the only reason the rollout switch in burner box is tripping is because the secondary heat exchanger is plugged up. as a carrier dealer i found a bad one today and have replaced secondarys on this...
  20. Replies
    2
    Views
    382

    carrier failed secondary's

    is it just me or are there a ton of carrier secondary failures with the 40" furnaces lp gas and natural
  21. Replies
    69
    Views
    7,355

    because we have been a carrier dealer for 40...

    because we have been a carrier dealer for 40 years, they make good equipment but sometimes people are only after price, and we all know price should not be the deciding factor but we all gotta put...
  22. Replies
    69
    Views
    7,355

    good to know tat about the mods and the bigger...

    good to know tat about the mods and the bigger coils, i sell york as a 2nd line but mostly the tm9x models or on ocassion the tg9, i really like the tm9x model its cost effecient and works good for...
  23. Replies
    69
    Views
    7,355

    14.5 seer with a bigger coil and txv with...

    14.5 seer with a bigger coil and txv with variable speed or x 13 motor will get you 16 seer and 13 eer
  24. Replies
    69
    Views
    7,355

    anybody thats not in this field will not know the...

    anybody thats not in this field will not know the differewnce, they will not know if its in 2nd stage or if its slowly modulating, hell i install carrier and i can hardly tell the difference between...
  25. Replies
    69
    Views
    7,355

    homeowner will not recognize the difference...

    homeowner will not recognize the difference between modulating and 3 stage