Search:

Type: Posts; User: mechmike2

Page 1 of 6 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    6
    Views
    322

    malicious site warning

    I keep getting this warning. Is something wrong with the site? Get it in both Firefox and IE
  2. Replies
    19
    Views
    774

    Took an advanced class that James Johnson from...

    Took an advanced class that James Johnson from Tridium (Vykon) put on, think it was 5 day. Lots of info, My head hurt. Good docs I still use. Would recommend.
  3. I had 4 RTUs all configured the same in both AX...

    I had 4 RTUs all configured the same in both AX and Field Assistant. 1 of the units would always read 100 degree return temp. I can't recall exactly how I got it to stop and read properly. I know it...
  4. I had the same problem, except it was 100. Had to...

    I had the same problem, except it was 100. Had to use Carrier Field Assistant and go into the UPC Open controller and in the property sheet view of the RA Temp tell it to not allow writing to the...
  5. Replies
    1
    Views
    194

    Solidyne to Ax

    Anyone integrated Solidyne controllers into a Jace using their M2 driver? How did it go?
  6. Replies
    3
    Views
    288

    Take a look at the Honeywell T775P2003. 4 relay...

    Take a look at the Honeywell T775P2003. 4 relay outputs, can be config'd various ways 1st on 1st off, equal runtime...etc
  7. Replies
    10
    Views
    410

    Do you have the scale of the canvas pane set to...

    Do you have the scale of the canvas pane set to "fit ratio" ?
  8. Replies
    41
    Views
    1,591

    N4- Ready for prime time?

    Just wondering if anyone has successfully set up and implemented a N4 site yet. Either migrated AX or new.
  9. Replies
    4
    Views
    346

    What version?

    What version?
  10. Replies
    2
    Views
    253

    Yes. Sensor is wired to input 2 and input 2 is...

    Yes. Sensor is wired to input 2 and input 2 is configured as IAQ Sensor. Sensor is reading properly in IO Point tab. Ended up linking System Space IAQ from input 2 and point now reads properly as...
  11. Replies
    2
    Views
    253

    RTU_Open IAQ problem

    Have an issue where my Input 2 sensor which is configured for IAQ Sensor is not coming across on the BacNet point "iaq". Also not showing up on graphic.

    30 new RTU's using ZS sensors with CO2,...
  12. I replaced the CP controllers with lon Spyders....

    I replaced the CP controllers with lon Spyders. Replaced the CP jaces also.
  13. Rip them out or have owner call Corporate...

    Rip them out or have owner call Corporate Honeywell for service. Had to do same in a building recently.
  14. Replies
    18
    Views
    577

    most VFDs now have the ability to control of a...

    most VFDs now have the ability to control of a sensor. Call manufacturer tech support and you'll be done.
  15. They are really simple when you "get it". At...

    They are really simple when you "get it". At appx. 7-8 psi heat should be off and damper at minimum. On RA as space temp rises-pressure drops and damper should open to add cooling, as space temp...
  16. Wouldn't it be the opposite (RA). Temp...

    Wouldn't it be the opposite (RA). Temp drop=pressure increase. Also only 1 wire on your PE in last pic, not going to do anything
  17. Thread: Trane BCI-I

    by mechmike2
    Replies
    12
    Views
    1,267

    Thanks. I have done a lot of LCI-I's but first...

    Thanks. I have done a lot of LCI-I's but first BCI-I, is it OK to write programmatically to the set points? Also any preferred tuning policys?

    I'm also wondering if any of those other...
  18. Thread: Spyder Help

    by mechmike2
    Replies
    10
    Views
    654

    If you are on the config page of PID just hit...

    If you are on the config page of PID just hit help. You have to close config page to view.
  19. Thread: Trane BCI-I

    by mechmike2
    Replies
    12
    Views
    1,267

    How do you change the Out of Service property...

    How do you change the Out of Service property from false to true?

    Do I have to bring the point out twice? 1 for Present Value and 1 for Out of Service.

    Even after doing that cannot command...
  20. Replies
    1
    Views
    296

    Integrated about 30 meters using it around 2...

    Integrated about 30 meters using it around 2 years ago. Had issues and got them resolved through their tech support, can't recall what issue was but they were helpful.
  21. Replies
    10
    Views
    914

    As always check software manager to be sure...

    As always check software manager to be sure modules match up and upgrade if needed
  22. Replies
    10
    Views
    914

    You will have no problem commissioning, or...

    You will have no problem commissioning, or working in general, on a Vykon jace with Webs workbench.
  23. Replies
    3
    Views
    322

    Google Phoenix SRV-100. Thats what we used or a...

    Google Phoenix SRV-100. Thats what we used or a fairly large Bacnet integration. Phoenix Rep.had to set up the server and expose the points, was a pain in the ass getting them to show points I...
  24. Replies
    5
    Views
    717

    Strange thing happened recently when I used...

    Strange thing happened recently when I used station copier to change name of a site. After changing the name and rebooting when I opened the App. Director there were 2 stations on the Jace Old name...
  25. Replies
    6
    Views
    427

    add your email to profile and I'll send you some...

    add your email to profile and I'll send you some docs
  26. Replies
    44
    Views
    2,471

    The drive creates it own 24 VDC for the DI's

    The drive creates it own 24 VDC for the DI's
  27. Replies
    1
    Views
    404

    There are some decent graphics in the...

    There are some decent graphics in the kitPxGraphics module. You can put together a decent ERV, animated wheel included.
  28. Replies
    71
    Views
    8,627

    I am also wondering what device you are talking...

    I am also wondering what device you are talking about. It would be great to get what a Jace offers without having to pay licensing fees, upgrade fees, memory upgrade fees,...

    Shenanigans ??
  29. Replies
    71
    Views
    8,627

    What I love about Niagara is that I can bring in...

    What I love about Niagara is that I can bring in multiple devices talking different protocols and bring them in to one place and give the end user what they want. Nothing in life is cheap.
  30. Replies
    7
    Views
    1,090

    Part 1 Ductwork Part 2 Piping Part 3 Service...

    Part 1 Ductwork
    Part 2 Piping
    Part 3 Service
    Part 4 Realize I'm 40 and hate doing above.
  31. Replies
    1
    Views
    502

    Start/Stop loops in the 15c is how scheduling is...

    Start/Stop loops in the 15c is how scheduling is done. You would link schedule from the "A" to the Start/Stop loop, then use a Logic Loop to control a DO (FanEnable) off the Start/Stop.
  32. Thread: Btu

    by mechmike2
    Replies
    9
    Views
    935

    Love it.

    Love it.
  33. Sorry, the Reflash tool is for Spyders.

    Sorry, the Reflash tool is for Spyders.
  34. Replies
    8
    Views
    646

    Does Effective Set Point reflect last change?

    Does Effective Set Point reflect last change?
  35. Add email to profile

    Add email to profile
  36. There is a reflash tool to upgrade or downgrade...

    There is a reflash tool to upgrade or downgrade firmware
  37. Replies
    1
    Views
    679

    Carrier Field Assistant 6.0

    I was told it was possible to use Firefox instead of I.E. as interface. Just installed FA 6.0 but can't find where to change default browser, still uses I.E..

    Anyone know?
  38. Replies
    33
    Views
    4,723

    I like the Niagara platform, constant version...

    I like the Niagara platform, constant version suck, but what else can do what it does? License a driver and integrate a device. Granted some are easier than others and docs sometimes suck, but who...
  39. Chipkin has some good manuals

    Chipkin has some good manuals
  40. Replies
    6
    Views
    736

    Done a few 15C to AX and the first definitely...

    Done a few 15C to AX and the first definitely sucks, but ain't that always the case?
    There is a "15C for learn" object that you would copy to lon network, match up device, do a learn, upload, and...
  41. Station Dislpay name in supervisor keeps changing

    How do you keep the display name of a niagara station in a supervisor from changing. Have reset it over and over but always goes back. Cannot figure out where it derives the display name.
  42. Replies
    9
    Views
    1,107

    If I recall correctly LonSpec backups are .ntb...

    If I recall correctly LonSpec backups are .ntb files unsure what .mdb files are.
  43. Replies
    5
    Views
    1,344

    you know whats weird---I get that same stupid...

    you know whats weird---I get that same stupid face thing for the letter P on one of my stations when it text messages. Don't know why. Just thought I'd throw it out there.
  44. Replies
    4
    Views
    584

    Each unit now has its own OA sensor. What they...

    Each unit now has its own OA sensor. What they want is a uniform OA temp which will be the same for all units. If I pick 1 unit to broadcast its OA temp then done deal, but where I could do that on a...
  45. Replies
    4
    Views
    584

    Carrier RTU-Open Outside Air Question

    Have a customer with a few sites that each have appx. 20 Carriers with RTU-Open controllers. The units, as is, use their individual OA sensor for various control strategy's. What customer would like...
  46. Replies
    5
    Views
    698

    7.67 is latest version as far as I know

    7.67 is latest version as far as I know
  47. Replies
    0
    Views
    462

    Reliatel to AX integration issue

    Doing a Trane Reliatel integration and am having an issue where I need to be able to allow the tenant to have set point adjustment from the wall sensor but only between ranges. Sensor installed are...
  48. Replies
    2
    Views
    498

    Sent you a palette that contains a 15C for Learn...

    Sent you a palette that contains a 15C for Learn device that makes it easier to work these devices. More info. on Buildings Forum on these devices also.
  49. Replies
    1
    Views
    336

    Adding modules to FX-60

    Have to add a Lon network to an FX-60, there are no lon modules install as it came, it is licensed for lonworks. I am leary of connecting to Johnson device with my Webs workbench and transferring the...
  50. Thread: vav help

    by mechmike2
    Replies
    6
    Views
    933

    KMC has some offerings for standalone VAVs. Going...

    KMC has some offerings for standalone VAVs. Going to try out their "Simple VAV" on a box tomorrow to see how they work.

    Envirotec another option for standalone.
Results 1 to 50 of 289
Page 1 of 6 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365