  1. Replies
    0
    Views
    242

    Tech Support - Carrollton TX

    Customer Assurance Manager (HVAC Tech Support)
    Location:Carrollton, TX
    Job Code:1275
    # of Openings:1
    Description
    Carrier Enterprise (CE) is a subsidiary of the largest independent HVAC/R...
  2. I strongly recommend getting real referrals....

    I strongly recommend getting real referrals. Angie's list, BBB, etc. are just advertising gimmicks. Nothing beats good credentials and direct customer references. I've seen scoundrels show up as top...
  3. If you are looking at short term occupancy that's...

    If you are looking at short term occupancy that's not a bad choice. If you plan to stay 6 years or more I would strongly recommend you take a look at the 288AN series. The most savings and the most...
  4. Replies
    5
    Views
    398

    Never

    Never
  5. Replies
    35
    Views
    3,431

    I've handled mitsubishi for years with very few...

    I've handled mitsubishi for years with very few problems. Carrier also has a good product right now. Some have been less than desireable in the past but this one seems to be pretty good.
  6. Replies
    5
    Views
    354

    Seal your ducts. Negative pressure in the home...

    Seal your ducts. Negative pressure in the home will cause air to come in from anywhere it can.
  7. Replies
    9
    Views
    395

    Agree do load calc on all jobs. In Texas the TDLR...

    Agree do load calc on all jobs. In Texas the TDLR is fining companies who fail to do this.
  8. Thread: oxy/acet

    by txssdad
    Replies
    32
    Views
    1,524

    Safety glasses are good for this.

    Safety glasses are good for this.
  9. Replies
    7
    Views
    394

    The pump down warning is primarily intended for...

    The pump down warning is primarily intended for "Pump Down Control" in which the system utilizes a solonoid and pressure switch to control the compressor cycles. Also I agree if it is a Novation coil...
  10. Replies
    17
    Views
    1,047

    Remember all reading are with the indoor...

    Remember all reading are with the indoor temperature at the ARI rated conditions. A house that is well above this point all numbers are going to be skewed. Weigh the charge in, run 24 hours, return...
  11. Replies
    11
    Views
    1,304

    That's the new down blow unit!!! LMAO. The term...

    That's the new down blow unit!!! LMAO. The term WOMBAT comes to mind. Waste Of Money, Brains, And Time!!!


    Sent from my iPad using Tapatalk HD
  12. Replies
    15
    Views
    842

    Caution should always be used when replacing an...

    Caution should always be used when replacing an OEM motor with a generic motor. Manufacturers have a tendency to under rate their motor name tags and a 1/2 hp motor could be closer to a 3/4. OEM Is...
  13. Replies
    24
    Views
    1,567

    Poll: This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  14. Replies
    6
    Views
    468

    I agree with the first two guys. Avoid buying...

    I agree with the first two guys. Avoid buying used AC equipment. To answer you question look for a W in the model number. ie 2TWR, 4TWX, 4TWZ, etc. the W is indicative of their trade name for heat...
  15. Replies
    1
    Views
    339

    Run. Sent from my iPad using Tapatalk HD

    Run.


    Sent from my iPad using Tapatalk HD
  16. Replies
    0
    Views
    354

    Tech Support position Carrollton Texas

    We currently have an exciting opportunity within the Central Region for a Customer Assurance Manager. This position is located in Carrollton, TX.

    Company Website: http://www.carrierenterprise.com...
  17. Replies
    16
    Views
    691

    I've installed and serviced many of the Chrysler...

    I've installed and serviced many of the Chrysler Airtemp units.


    Sent from my iPad using Tapatalk HD
  18. Replies
    18
    Views
    22,965

    Air Knight

    The Air Knight is exactly the same as the RGF Guardian Air unit. It is manufactured by RGF and packaged for Carrier/Total Line. According to RGF there is no difference in the 2 products.
Results 1 to 18 of 18