Search:

Type: Posts; User: Rob_in_WV

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. just for giggles what is your super heat reading?...

    just for giggles what is your super heat reading? That might be a nice little clue to help out a little.
  2. Thread: Stumped

    by Rob_in_WV
    Replies
    11
    Views
    476

    An oversized piston most likely will be bringing...

    An oversized piston most likely will be bringing liquid refrigerant back to the compressor too, might be why the compressor had to be changed out.
  3. Replies
    9
    Views
    436

    Would slowing the blower by one speed reduce the...

    Would slowing the blower by one speed reduce the amount of air just enough to do what you are shooting for?
  4. Thread: How long...

    by Rob_in_WV
    Replies
    20
    Views
    703

    Brian I say this deal is gonna be pretty...

    Brian I say this deal is gonna be pretty lucrative for JJ and Big Al and any of the other race baiters. Glenn if it were the other way around the whites would be told they are taking it too serious...
  5. Thread: How long...

    by Rob_in_WV
    Replies
    20
    Views
    703

    They handed down a lifetime ban and huge fine to...

    They handed down a lifetime ban and huge fine to the Clippers owner today.
  6. Replies
    30
    Views
    1,564

    I would think the compressor would start...

    I would think the compressor would start bypassing before a person could overcharge it that much. I bet the poor compressor was screaming for mercy.
  7. Replies
    25
    Views
    1,063

    Does the drain line have a trap on it? Also is...

    Does the drain line have a trap on it? Also is there a crack in the pan? This being a slant type coil the condensate pan is in the lower left hand side of the airhandler and runs from front to back.
  8. Defrosting every 90 minutes isn't unreasonable,...

    Defrosting every 90 minutes isn't unreasonable, The reason it feels like the A/C is running during a defrost cycle is that it does switch to A/C mode during defrost and the board should send 24...
  9. Replies
    17
    Views
    739

    I've never tested this idea, But I suppose it's...

    I've never tested this idea, But I suppose it's possible for it to back feed down the Orange wire into the air handler. I may have to rig something up with some old parts and test this idea.
  10. I certainly wouldn't want to be the one to...

    I certainly wouldn't want to be the one to question his diagnosis while he's packing that much heat.
  11. Replies
    18
    Views
    824

    Perhaps his guests should have told him to shut...

    Perhaps his guests should have told him to shut up and let them speak before they(the guest) starting whooping some British a** like it's 1776
  12. Kefah stay safe friend and I pray for you and...

    Kefah stay safe friend and I pray for you and your family to be safe.
  13. Replies
    16
    Views
    888

    Thanks to the guys who clarified that, I hadn't...

    Thanks to the guys who clarified that, I hadn't seen that yet and you may have saved me a deer in the headlights look.

    To the homeowner,I'll cut to my point, you hooked one wire up to Rc correct?...
  14. Replies
    16
    Views
    888

    Both actually, I'm intrigued by this jumper...

    Both actually, I'm intrigued by this jumper between y and w. But more so the new base.
  15. Replies
    16
    Views
    888

    Take a picture of the base where the wires...

    Take a picture of the base where the wires connect to it. Also the answer to your dilemma as it is perceived in my mind should be in the installation manual.
  16. Replies
    20
    Views
    898

    Has duct work been ran to the addition? It sounds...

    Has duct work been ran to the addition? It sounds like you are getting heat migrating to that part of the home more so than actually having it supplied by duct work or a crappy job was done with...
  17. Yes the pressure inside the A-coil will increase...

    Yes the pressure inside the A-coil will increase with the increase in temperature of the air through the coil and even as the temperature of the coil itself increases.
  18. Replies
    5
    Views
    307

    Has he called the local supply houses with the...

    Has he called the local supply houses with the numbers on the switch and furnace? Also he may have to utilize a universal switch if the furnace is very old.
  19. Replies
    17
    Views
    1,055

    In my home I use the cheap fiberglass throw away...

    In my home I use the cheap fiberglass throw away filter and change it monthly. Those filters listed as 3 month filters are highly restrictive and despite being sold as 90 filters only have a SAFE...
  20. Replies
    13
    Views
    702

    I don't classify the filtrete or 3m filters as...

    I don't classify the filtrete or 3m filters as media filters.
  21. Replies
    13
    Views
    702

    Saw you posted another thread about the same...

    Saw you posted another thread about the same furnace and you mentioned the filters. What size are they and how thick are they 1,2 or 4 inch? As was stated in the other thread, unless it's a media...
  22. Replies
    13
    Views
    702

    The limit is most likely weak due to repeated...

    The limit is most likely weak due to repeated high temperature cut offs. Get a pro to replace the limit and most importantly he will determine what caused it to cycle so much that it started failing....
  23. It most likely is/was frost, If that is the case...

    It most likely is/was frost, If that is the case and the issue persists call your local service provider and have them give it a check to see if the defrost sequence is working properly and the...
  24. In your dealings with the Maintenance crew have...

    In your dealings with the Maintenance crew have they mentioned replacing a "heat sequencer"?
  25. On emergency heat, when you say you tried 69 or...

    On emergency heat, when you say you tried 69 or 70 degrees: Does it fail to reach 69 or 70 degrees or does it over shoot the set point and get too hot in the home?
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4