Search:

Type: Posts; User: swift one

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    10
    Views
    339

    Gaffers????

    Gaffers????
  2. Replies
    6
    Views
    294

    x2

    x2
  3. I have used a plastic tarp sip screwed it to the...

    I have used a plastic tarp sip screwed it to the wall behind the evap dropped/removed evap pan.Got a rubber made large trash can (55gal) with the detachable wheels/caddy bottom, directed the tarp...
  4. smeq,this one of four 2 barrel systems this one...

    smeq,this one of four 2 barrel systems this one is the most popular of flavors.(coke)the owner has to make a decision for he has bought this store and the large chain co.(previous owner) has let the...
  5. Replies
    12
    Views
    945

    Tail meat is very tough,sharp knife and...

    Tail meat is very tough,sharp knife and (BFH):censored: or meat mallet
  6. smeq, thanks for insight Hot gas diaphram was...

    smeq, thanks for insight Hot gas diaphram was bleeding the disk had bubble in it. question have you ever changed foam pack/evap barrel on one of these.the unit next to this one all valves and sensors...
  7. WOW well spoken newold

    WOW well spoken newold
  8. Replies
    7
    Views
    458

    danfoss has a couple up and running in EUROPE...

    danfoss has a couple up and running in EUROPE...
  9. yes both barrel valves are energized and out let...

    yes both barrel valves are energized and out let temp drops. However not dropping enough#2 barrel. I was thinking hot gas bleeding,txv seat worn?? On start up ib valve outlet gets cold /cool and...
  10. cornelius pinnacle fcb where to start, or run away

    have one 2 flavor low on refrigerant.weighed in proper amount 20oz barrel 1 just fine barrel 2 wont freeze. ib will not drop below 49 in or out.this has become a huge challenge to say the least....
  11. Defrost timers are very common on med temp...

    Defrost timers are very common on med temp coolers. Here in the south RH cause heavy frosting of evaps
  12. Replies
    23
    Views
    2,330

    x2

    x2
  13. Quite common here if your talking about a utility...

    Quite common here if your talking about a utility bed on pickup truck. Ford, chevy,dodge etc... fleet sales at any dealer can find/outfit for you.
  14. Replies
    11
    Views
    1,028

    with r12 likely unnecessary,more so with 134a(cap...

    with r12 likely unnecessary,more so with 134a(cap tube replacement)
  15. Replies
    13
    Views
    1,045

    The same problem i had this past summer with 2...

    The same problem i had this past summer with 2 true reach-in freezer (3door and 2door) I replace Defrost timer, only to be called back. Thats when fumbling around in the center electrical panel the...
  16. Replies
    13
    Views
    2,609

    Marvin was a true friend.He forgot more than i'll...

    Marvin was a true friend.He forgot more than i'll ever could hope to know. Brought me up in this trade always asked how my kids were doing. Loved you Marv. R.I.P Thank you.Will
  17. Replies
    35
    Views
    2,891

    This may help/ or thought If this unit has a...

    This may help/ or thought If this unit has a baklite blower terminal block in the blower section. remove/ jump around it. Had same problem years back. With a trane gas pak. If memory serves me...
  18. Replies
    12
    Views
    607

    I did two this past summer 1st was a down draft...

    I did two this past summer 1st was a down draft most expensive 5ton curb ever. 2nd was side draft on a stand made of angle iron.and a huge transition. Had curb mfg come out and measure. made it very...
  19. My 2 cents tells me there is a part/chunk of the...

    My 2 cents tells me there is a part/chunk of the valve reed floating in the discharge line in a bend/90 cut into that dude.
  20. Rusty power head

    Change power head. Usally the problem. Under the insulation you will find it badly rusted. Also readly avalibale at supply counter.
  21. Replies
    44
    Views
    3,142

    JPSmith right on man. We all live with mistakes....

    JPSmith right on man. We all live with mistakes. Human.. no question. To live crooked eff them eff them all.
  22. Replies
    4
    Views
    583

    nice van

    Man you would lose weigth running service in a black anything.. in Texas
  23. Thread: bev air t-17

    by swift one
    Replies
    4
    Views
    594

    bev air t-17

    Changed filter driers back blew through evap/cap tube. both up and running. usually the nomanclature on comp- are discolored when comp- have suffered hi temps/press. both driers were restricted.
  24. Thread: bev air t-17

    by swift one
    Replies
    4
    Views
    594

    bev air t-17

    With this model why not run refer lines back up the middle of the case w/the drain line.Just my thinking. Hence when you pull the cond- unit there is a real possibility of a kink.. Too the point i...
  25. Replies
    75
    Views
    5,063

    IMHO

    bin stat.