  1. Replies
    14
    Views
    3,694

    Turbo is a maker of large commercial ice makers.I...

    Turbo is a maker of large commercial ice makers.I service two 25 ton units and a 10 ton unit at one location.They make sheets (plates) of ice.
  2. Replies
    5
    Views
    851

    This set up will work.If your beer trunk consists...

    This set up will work.If your beer trunk consists of two copper lines surrounded by the vinyl beer lines and wrapped in rubatex you have what we see here very often.The AEV is a constant pressure...
  3. Replies
    6
    Views
    792

    I already have this answer but I want you guys to...

    I already have this answer but I want you guys to try it out.If you have take out salad (potato, macaroni) in a cooler, stored in a styrofoam container over night in the cooler and the cooler is at...
  4. Replies
    91
    Views
    10,456

    Had a customer take my service van a few blocks...

    Had a customer take my service van a few blocks away from his store and hid it on me. Last time I ever left my keys in a vehicle.
  5. Replies
    19
    Views
    2,364

    Leak testing is an art that belongs in our trade....

    Leak testing is an art that belongs in our trade. Learn how to do it properly and put that leak seal crap with buddies 'Redtech' refrigerant.
  6. Replies
    38
    Views
    7,348

    To think that you paid this jerk-off any money is...

    To think that you paid this jerk-off any money is insane. This guy is a licenced hack and should be reported before he screws anybody else.Sorry about your luck.
  7. Replies
    16
    Views
    1,522

    Canadian water is 10 lbs per gallon, must be all...

    Canadian water is 10 lbs per gallon, must be all that fish we got up here.
  8. Replies
    14
    Views
    1,079

    grandmothers are both dead. my mother happens to...

    grandmothers are both dead. my mother happens to be 92 years old. Brought her to east coast of Canada this past August.
  9. Replies
    8
    Views
    826

    I have done many installs for a company called...

    I have done many installs for a company called Canadian Curtis Refrigeration. We do o.k on them and end up with all the customers after.
  10. Replies
    9
    Views
    1,044

    I think that stuff has a red dye in it. Get some...

    I think that stuff has a red dye in it. Get some liquid out of the jug to see if it does then put the jug in the garage and forget you have it.
  11. Replies
    2
    Views
    739

    Sporlan forever!

    Sporlan forever!
  12. Replies
    11
    Views
    2,281

    Order OEM valve from Manitowoc. I always try to...

    Order OEM valve from Manitowoc. I always try to install original parts and then there is no second guessing the part.Why was the first one replaced?
  13. Replies
    17
    Views
    1,862

    As soon as pilot is lit with a steady flame...

    As soon as pilot is lit with a steady flame touching the flame sensor then the main burners should light. Check for 24 volts between PVMV terminal and MV terminal on gas valve. If 24 volts is present...
  14. Replies
    12
    Views
    1,350

    If you are getting an amp draw on the...

    If you are getting an amp draw on the compressor?, and your gauges are hooked up at the compressor then you either have a rotary compressor running backwards or a recip that is pooched.Not pumping...
  15. air conditioning condenser fan cycle control set...

    air conditioning condenser fan cycle control set to 270# cut in and 170# cut out . 100# differential.period. I live where night time ambient can get quite low and if fan cycle differential is too...
  16. Replies
    46
    Views
    9,114

    first off that is very unsafe, you would have to...

    first off that is very unsafe, you would have to be crazy to climb it. If anyone doesn't think it is unsafe you're a moron. second, a monkey would be embarrassed to climb that junk. here $200.00...
  17. Replies
    16
    Views
    1,927

    If it has an oil separator the float in the...

    If it has an oil separator the float in the separator is probably stuck open. I just replaced one with this problem only two weeks ago. At defrost pump down, compressor could only pull down to about...
  18. Replies
    4
    Views
    669

    never replace blown fuses before you have...

    never replace blown fuses before you have thoroughly tested for grounds and/or shorts,and then stand to one side when you turn that disconnect back on. That compressor must have been grounded and a...
  19. Replies
    7
    Views
    820

    I have been self employed for 12 years. Worked...

    I have been self employed for 12 years. Worked for a great company for 11 years prior to that. Starting my own business has been amazing, quality of life is way up there and I have told a few jerks...
  20. R12 is right. Take the time to do the best you...

    R12 is right. Take the time to do the best you can so your not wasting time doing a call back. We also have 1/3 and 1/4 HP condensing units in the shop ready to go.Saves some time on site. Remember...
  21. Thread: taylor freezers

    by jemair
    Replies
    4
    Views
    993

    taylor freezer

    customer switched product sides and problem is still on the left side. going there tomorrow to recover charge in case the R502 is crossed with R408 or some other unknown refrig from previous company....
  22. Thread: taylor freezers

    by jemair
    Replies
    4
    Views
    993

    has anyone ever run across this type of problem....

    has anyone ever run across this type of problem. Taylor model 339 soft serve machine, vanilla (left side) won't stand up, soft appearance. product temperature is 15 degrees, normal should be 18 to 20...
  23. Thread: copeland

    by jemair
    Replies
    20
    Views
    3,010

    if the power element is broken (lost charge) the...

    if the power element is broken (lost charge) the tx closes off, system will go into a vacuum and stay there. Must still know if a cpr is in the unit. If no cpr troubleshoot metering device, if there...
  24. Thread: copeland

    by jemair
    Replies
    20
    Views
    3,010

    copeland compressor with low suction.

    you are bound to find a cpr valve on that hussman that is not openning propely.